Electrical Characteristics
www.RFM.com
©2008 by RF Monolithics, Inc.
1.
2.
3.
4.
5.
6.
7.
8.
9.
• Medical Band (402-405 MHz) Front-End Filter
• Low-Loss, Coupled-Resonator (Lithium Tantalate) LiTa03 Design
• Complies with Directive 2002/95/EC (RoHS)
The RF1419D is a surface-acoustic-wave (SAW) filter designed to provide front-end selectivity in the 402-405
MHz band. This filter is ideal for short range wireless medical data applications where small size and low
power consumption are required features. Receiver designs using this filter include superhet, direct
conversion or superregen. RFM’s advanced SAW design and fabrication technology is utilized to achieve high
performance and optimum loss with simple external impedance matching.
Characteristic
Center Frequency at 25°C
Insertion Loss
Passband Ripple (Relative to ILMIN) 402-405 MHz
3 dB Bandwidth
Rejection Attenuation: (relative to ILmin)
Temperature
Frequency Aging
Impedance Match
Lid Symbolization (Y=year WW=week S=shift)
Standard Reel Quantity
Unless noted otherwise, all measurements are made with the filter installed in the specified test fixture which is connected to a 50
The frequency f
Where noted specifications apply over the entire specified operating temperature range of -10°C to +60°C.
Frequency aging is the change in fc with time and is specified at +65°C or less. Aging may exceed the specification for prolonged temperatures
above +65°C. Typically, aging is greatest the first year after manufacture, decreasing significantly in subsequent years.
The design, manufacturing process, and specifications of this device are subject to change.
One or more of the following U.S. Patents apply: 4,54,488, 4,616,197, and others pending.
All equipment designs utilizing this product must be approved by the appropriate government agency prior to manufacture or sale.
Tape and Reel Standard Per ANSI / EIA 481.
This product complies with Directive 2002/95/EC of the European Parlament and of the Council of 27 January 2003 on the restriction of the use of
certain hazadous substances in electrical and electronic equipment.
CAUTION: Electrostatic Sensitive Device. Observe precautions for handling.
Notes:
E-mail: info@rfm.com
c
is defined as the midpoint between the 3dB frequencies.
Absolute Frequency
Freq. Temp. Coefficient
Absolute Value during the First Year
Input/Output
Reel Size 7 Inch
Reel Size 13 Inch
358.5 - 384 MHz
415 - 423 MHz
423 - 503 MHz
10
358.5 MHz
Pb
Sym
IL
BW
FTC
|fA|
f
MIN
c
3
Notes
1, 2, 3
1, 3
1, 3
1, 3
1, 3
1
5
9
Minimum
3.0
40
35
25
40
560 // YWWS
Typical
403.5
3000 Pieces/Reel
500 Pieces/Reel
1.60
1.10
7.5
-37
65
50
35
50
10
50 Ohms
SAW Filter
403.5 MHz
RF1419D
SM3838-8 Case
3.8 x 3.8
Maximum
1.25
2.5
RF1419D - 3/21/08
test system.
ppm/yr
Page 1 of 3
Units
ppm/k
MHz
MHz
dB
dB
dB