5EFM4S Tyco Electronics, 5EFM4S Datasheet - Page 4

MODULE POWER ENTRY 5A GP 4V SW

5EFM4S

Manufacturer Part Number
5EFM4S
Description
MODULE POWER ENTRY 5A GP 4V SW
Manufacturer
Tyco Electronics
Series
Mr
Type
IEC 320-C14 (Male Pins)r
Datasheets

Specifications of 5EFM4S

Current
5A
Features
Fuse Holder, Switches, On/Off, Non-Illuminated, Voltage Selector
Filter Type
General Purpose
Fuse Drawer
Included
Mounting Type
Panel Mount, Screw Hole
Termination Style
Quick Connect - .110" (2.8mm)
Voltage
120VAC
Gender
Plug
Voltage Rating
250VAC
Current Rating
5A
Connector Mounting
Flange
Termination Type
Quick Connect
Inductance Min
930µH
Connector Type
Filtered / Fused Power Entry
Filtered
Yes
Leakage Current
0.5 mA
Type Of Inlet
Power Entry (Filtered/Unfiltered)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
1609129-9
2-1609129-8
2-6609129-8
CCM1023
Neutral
Hot
Hot
Note 1:
Note 2:
Note 3:
Note 4:
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
Neutral
Neutral
Hot
Note 2
Power On/Off
Note 2
Power On/Off
Note 2
Jumper required if no input filter is used
Provision for dual Metric style fusing
On/off switch present only in “S” suffix models
When using a center-tapped transformer, the C-F winding should be the
low voltage (high current) winding and must be capable of handling the full
primary current in the 120V position
Note 3
Note 3
Power On/Off
K
L
Note 3
K
L
Note 1
Note 1
Note 1
Note 1
120V
H
J
120V
100V
H
J
240V
A
B
C
D
E
F
G
B
D
E
F
K
G
L
230V
240V
Transformer Primaries
A
B
C
D
E
F
G
Transformer Primaries
Transformer Primaries
120V
120V
K
L
Customer
A
C
D
E
F
Customer
Customer
120V
100V
120V
20V
A
C
F
Note 4
120V
120V
Phase
Phase
Note 1:
Note 2:
Note 3:
Note 4:
Neutral
Neutral
Neutral
Phase
Phase
Neutral
Power On/Off
Note 1
Note 1
Provision for dual Metric style fusing
On/off switch present only in “S” suffix models
Line to ground capacitor not present on HM models
Models HM4, FM4, XM4 and ZM4 have added terminals K and L.
External switch or jumper must be placed from K to H and L to J
Power On/Off
Note 2
Note 2
Note 2
Note 3
Power On/Off
Note 2
Note 3
Power On/Off
Note 1
K
L
K
L
Note 1
Note 4
Note 4
Note 4
Note 4
120V
100V
120V
100V
H
J
H
J
H
J
H
J
230V
240V
B
A
C
D
E
F
G
B
F
G
230V
240V
B
F
G
B
C
A
D
E
F
G
Transformer Primaries
Transformer Primaries
C
D
A
E
F
C
D
A
E
F
Customer
Customer
120V
100V
120V
20V
100V
20V

Related parts for 5EFM4S