6CUFS1 Tyco Electronics, 6CUFS1 Datasheet - Page 5

MODULE POWER ENTRY SNAP-IN 6A

6CUFS1

Manufacturer Part Number
6CUFS1
Description
MODULE POWER ENTRY SNAP-IN 6A
Manufacturer
Tyco Electronics
Series
CUr
Type
IEC 320-C14 (Male Pins)r
Datasheets

Specifications of 6CUFS1

Current
6A
Features
Fuse Holder, Switch On/Off Non-Illuminated
Filter Type
General Purpose
Fuse Drawer
Fuse Not Required
Mounting Type
Panel Mount, Snap-In
Termination Style
Quick Connect - .187" (4.7mm)
Voltage
250VAC
Gender
Plug
Voltage Rating
250VAC
Current Rating
6A
Connector Mounting
Snap-In
Contact Termination
Quick Connect
Connector Type
Filtered Power Entry
Mounting Style
Snap-In
Filtered
Yes
Leakage Current
0.25 mA, 0.4 mA
Product
Power Entry Filter Modules
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
2-1609113-9
CCM1891
CASE DIMENSIONS cont.
RECOMMENDED pANEl CutOut
CuFE1
CuFS1
typical Dimensions
Mounting holes (2) : .132 [3.35] Dia. with .260 [6.6] Dia. x 90°
countersink for #4 or M3 flathead screw
line Inlet (1) : IEC 60320-1 C14
load terminals (2) : .188 [4.8] with .07 [1.8] Dia. hole
Ground terminal (1) : .188 [4.8] with .16 x .07 [4.1 x 1.8] slot
typical Dimensions
line Inlet (1) : IEC 60320-1 C14
load terminals (2) : .188 [4.8] with .07 [1.8] Dia. hole
Output Shroud, Inside dimension : .21 x .34 [5.2 x 8.6]
Ground terminal (1) : .188 [4.8] with .16 x .07 [4.1 x 1.8] slot
R. Max
E
A
F
A
C
D
F
C
B
B
Panel Thickness
CUFS1, CUS1
CU10S1
CU15S1
CUFF1
Note : R=1.8 [45.72] for CUFF, 1.0 [25.4] for all others.
.025 - .082 [ 0.63 - 2.1 ]
.028 - .039 [ 0.7 - 1.0 ]
.047 - .059 [ 1.2 - 1.5 ]
.157 [ 4.0 ] Max
CuFF1
typical Dimensions
Mounting holes (2) : M3 x .5
line Inlet (1) : IEC 60320-1 C14
load terminals (2) : .188 [4.8] with .07 [1.8] Dia. hole
Ground terminal (1) : .188 [4.8] with .16 x .07 [4.1 x 1.8] slot
A
F
C
B