RG82852GME Intel, RG82852GME Datasheet - Page 9

no-image

RG82852GME

Manufacturer Part Number
RG82852GME
Description
Manufacturer
Intel
Datasheet

Specifications of RG82852GME

Lead Free Status / RoHS Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
RG82852GME
Manufacturer:
INTEL
Quantity:
239
Errata
1.
Problem:
Implication: Entire scan lines will appear to flicker in some VGA diagnostic and stress test applications. However,
Workaround: No workaround exists.
Status:
2.
Problem:
Implication: 40-column VGA modes may experience visual color anomalies on some CRT monitors. This was
Workaround: No workaround exists.
Status:
10
A1,B1 - VGA Panning
VGA text mode diagnostic and stress test applications that use pixel panning can experience temporary
visual anomalies under certain memory configurations. This issue is seen in two test configurations.
there are no known customer sightings of this erratum. No known end user applications fail for this
erratum.
There are no plans to fix this erratum in silicon..
A2,B2 - VGA Timings
Some VGA applications, running in 40-column modes that use a non-black border color may experience
color/visual issues on systems configured with certain monitors.
observed using VGA focused Intel test software. With certain monitors, colors in active areas may
change as the border color changes. As observed while using the test software, visual color anomalies
can range from a slight color change difference to a blank screen. Based on the lack of customer or end
user reported issues related to this erratum, the number of VGA applications that run in 40-column
modes and also use non-black border colors is low. Based on Intel’s validation and compatibility testing,
the number of CRT monitors that exhibit this color anomaly is also low.
There are no plans to fix this erratum in silicon
1. Test applications using a single VGA font table with a 32KB font buffer range could fail. The
2. Test applications using multiple VGA font tables could fail if the first two fonts are from different
failure can occur using 64MB technology products that use 2KB and 4KB page sizes. This failure
was seen in a diagnostic utility.
tables. This failing condition can occur in any memory configuration. This failure was seen in a
stress test utility.
Intel
®
852GME/852PM Specification Update
R