HFBR-5113 Avago Technologies US Inc., HFBR-5113 Datasheet - Page 11

HFBR-5113

Manufacturer Part Number
HFBR-5113
Description
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of HFBR-5113

Operating Temperature Classification
Commercial
Operating Supply Voltage (min)
4.75V
Operating Supply Voltage (typ)
5V
Operating Supply Voltage (max)
5.25V
Mounting
Through Hole
Lead Free Status / RoHS Status
Compliant
Figure 12. Signal Detect Thresholds and Timing.
Figure 10. Output Optical Pulse Envelope.
-0.025
1.025
0.975
0.025
-0.05
1.25
1.00
0.90
0.50
0.10
0.0
ANS – MAX — MAXIMUM ACQUISITION TIME (NO SIGNAL).
AS – MAX — MAXIMUM ACQUISITION TIME (SIGNAL).
THE HFBR-511X OUTPUT OPTICAL PULSE SHAPE FITS WITHIN THE BOUNDARIES
OF THE PULSE ENVELOPE FOR RISE AND FALL TIME MEASUREMENTS.
SIGNAL – DETECT (OFF)
SIGNAL – DETECT (ON)
INTERVAL
0% TIME
AS – MAX IS THE MAXIMUM SIGNAL – DETECT ASSERTION TIME FOR THE STATION.
AS – MAX SHALL NOT EXCEED 100.0 µs. THE DEFAULT VALUE OF AS – MAX IS 100.0 µs.
ANS – MAX IS THE MAXIMUM SIGNAL – DETECT DEASSERTION TIME FOR THE STATION.
ANS – MAX SHALL NOT EXCEED 350 µs. THE DEFAULT VALUE OF AS – MAX IS 350 µs.
-31.0 dBm
-45.0 dBm
10.0
5.6
1.975
4.40
0.075
INPUT OPTICAL POWER
( > 1.5 dB STEP INCREASE)
P
A
(P
< P
AS – MAX
80 ± 500 ppm
O
1.525
0.525
4.850
TIME – ns
A
± 0.725
+ 1.5 dB
< -31.0 dBm)
100% TIME
INTERVAL
TIME
40 ± 0.7
10.0
± 0.725
INPUT OPTICAL POWER
( > 4.0 dB STEP DECREASE)
0.075
1.975
MIN (P
P
(P
5.6
4.40
O
S
= MAX (P
= INPUT POWER FOR BER < 10
O
+ 4.0 dB OR -31.0 dBm)
ANS – MAX
S
OR -45.0 dBm)
1.525
0.525
4.850
11
Figure 11. Relative Input Optical
Power vs. Eye Sampling Time
Position.
CONDITIONS:
1.T
2. V
3. INPUT OPTICAL RISE/FALL TIMES = 1.0/2.1 ns.
4. INPUT OPTICAL POWER IS NORMALIZED TO
5. NOTE 20 AND 21 APPLY.
2
)
CENTER OF DATA SYMBOL.
A
CC
5
4
3
2
1
0
-4
= 25° C
EYE SAMPLING TIME POSITION (ns)
= 5 Vdc
-3
-2
1.0 x 10
2.5 x 10
-1
-12
-10
0
BER
BER
1
2
3
4

Related parts for HFBR-5113