IS42S16400C1-6T ISSI, Integrated Silicon Solution Inc, IS42S16400C1-6T Datasheet - Page 13

no-image

IS42S16400C1-6T

Manufacturer Part Number
IS42S16400C1-6T
Description
Manufacturer
ISSI, Integrated Silicon Solution Inc
Type
SDRAMr
Datasheet

Specifications of IS42S16400C1-6T

Organization
4Mx16
Density
64Mb
Address Bus
14b
Access Time (max)
6/5ns
Maximum Clock Rate
166MHz
Operating Supply Voltage (typ)
3.3V
Package Type
TSOP-II
Operating Temp Range
0C to 70C
Operating Supply Voltage (max)
3.6V
Operating Supply Voltage (min)
3V
Supply Current
130mA
Pin Count
54
Mounting
Surface Mount
Operating Temperature Classification
Commercial
Lead Free Status / RoHS Status
Not Compliant
IS42S16400C1
AC ELECTRICAL CHARACTERISTICS
Notes:
1. When power is first applied, memory operation should be started 200 µs after V
2. Measured with t
3. The reference level is 1.4 V when measuring input signal timing. Rise and fall times are measured between V
4. Access time is measured at 1.4V with the load shown in the figure below.
5. The time t
6. If clock rising time is longer than 1ns, tr/
Integrated Silicon Solution, Inc. — www.issi.com —
Rev. E
10/25/05
Symbol Parameter
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
T
CK3
CK2
AC3
AC2
CHI
CL
OH3
OH2
LZ
HZ3
HZ2
DS
DH
AS
AH
CKS
CKH
CKA
CS
CH
RC
RAS
RP
RCD
RRD
DPL3
DPL2
DAL3
DAL2
REF
Also note that the power-on sequence must be executed before starting memory operation.
(max.).
when the output is in the high impedance state.
Clock Cycle Time
Access Time From CLK
CLK HIGH Level Width
CLK LOW Level Width
Output Data Hold Time
Output LOW Impedance Time
Output HIGH Impedance Time
Input Data Setup Time
Input Data Hold Time
Address Setup Time
Address Hold Time
CKE Setup Time
CKE Hold Time
CKE to CLK Recovery Delay Time
Command Setup Time (CS, RAS, CAS, WE, DQM)
Command Hold Time (CS, RAS, CAS, WE, DQM)
Command Period (REF to REF / ACT to ACT)
Command Period (ACT to PRE)
Command Period (PRE to ACT)
Active Command To Read / Write Command Delay Time
Command Period (ACT [0] to ACT[1])
Input Data To Precharge
Command Delay time
Input Data To Active / Refresh
Command Delay time (During Auto-Precharge)
Transition Time
Refresh Cycle Time (4096)
HZ
(max.) is defined as the time required for the output voltage to transition by ± 200 mV from V
T
= 1 ns.
(6)
(4,6)
(5)
CAS Latency = 3
CAS Latency = 2
CAS Latency = 3
CAS Latency = 2
CAS Latency = 3
CAS Latency = 2
CAS Latency = 3
CAS Latency = 2
CAS Latency = 3
CAS Latency = 2
CAS Latency = 3
CAS Latency = 2
2
- 0.5ns should be added to the parameter.
(1,2,3)
1-800-379-4774
2CLK+t
2CLK+t
1CLK+3
2CLK
2CLK
Min.
7.5
2.5
2.5
1.5
0.8
1.5
0.8
1.5
0.8
1.5
0.8
60
42
18
18
12
6
2
2
0
1
-6
RP
RP
100,000
Max.
10
64
5
6
5
6
DD
2CLK+t
2CLK+t
1CLK+3
2CLK
2CLK
and V
Min.
7.5
2.5
2.5
2.7
1.5
0.8
1.5
0.8
1.5
0.8
2.0
63
37
15
15
14
7
3
0
1
1
RP
RP
-7
DDQ
100,000
Max.
5.4
5.4
10
64
6
6
reach their stipulated voltages.
OH
(min.) or V
IH
(min.) and V
ISSI
OL
(max.)
IL
Units
ms
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
13
®

Related parts for IS42S16400C1-6T