SI2415-C-FTR Silicon Laboratories Inc, SI2415-C-FTR Datasheet - Page 41

no-image

SI2415-C-FTR

Manufacturer Part Number
SI2415-C-FTR
Description
Manufacturer
Silicon Laboratories Inc
Datasheet

Specifications of SI2415-C-FTR

Main Category
Chipset
Data Rate
54.6875Kbps
Power Supply Type
Analog
Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (min)
3V
Operating Supply Voltage (max)
3.6V
Operating Temp Range
0C to 70C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
SI2415-C-FTR
Quantity:
2 409
S-Register
(Decimal)
42
43
44
50
51
Blacklisting—The Si2457/34/15/04 will not dial the
same number more than two times in three minutes.
An attempt to dial a third time within three minutes will
result in a “BLACKLISTED” result code. If the blacklist
memory is full, any dial to a new number will result in a
“BLACKLIST FULL” result code. Numbers are added
to the blacklist only if the modem connection fails. The
%B command will list the numbers on the blacklists.
0 = disabled
1 = enabled
Dial Attempts to Blacklist.
When blacklisting is enabled with S42, this value con-
trols the number of dial attempts that will result in a
number being blacklisted.
Blacklist Timer.
Period during which blacklisting is active.
Minimum on-hook time—Modem will remain on-hook
for S50 seconds. Any attempt to go off-hook will be
delayed until this timer expires.
Number to start checking for an outside line on a PBX.
See &X command for details.
Table 15. S-Register Description (Continued)
Function
Definition
Rev. 1.1
0 (disabled)
(Decimal)
Default
180
4
3
1
Si2457/34/15/04
Range
0–255
0–255
0–1
0–4
0–9
seconds
seconds
Units
41