W2E143-AA09-88 EBM-Papst Industries Inc, W2E143-AA09-88 Datasheet - Page 4

FAN TUBEAXIAL 172X51MM 230VAC

W2E143-AA09-88

Manufacturer Part Number
W2E143-AA09-88
Description
FAN TUBEAXIAL 172X51MM 230VAC
Manufacturer
EBM-Papst Industries Inc
Series
W2E143r

Specifications of W2E143-AA09-88

Bearing Type
Ball
Voltage Rating
230VAC
Power (watts)
29W
Size / Dimension
Round - 172mm Dia x 51mm W
Termination
2 Terminals
Fan Type
Tubeaxial
Termination Style
60 dB(A)
Air Flow
260.0 CFM (7.36m³/min)
Weight
2.2 lbs (997.9g)
Noise
60 dB(A)
External Depth
51mm
External Diameter
172mm
Current Type
AC
Supply Voltage
230VAC
Flow Rate
260CFM
Noise Rating
60dBA
Power Connection Type
Terminal
Diameter
172mm
Flow Rate - Imperial
260CFM
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Rpm
-
Static Pressure
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
W2E143AA0988
Prerequisites
➜ Check whether the data on the type plate agree with the connection data.
➜ Before connecting the device, ensure that the mains supply voltage
➜ Only use cables designed for current according to
Residual current operated device
Voltage control
Frequency inverter
Motor protection
Connecting cables with terminals (applicable only to devices with terminal
connection)
4/5
matches the fan voltage.
the type plate.
Only all-current-sensitive RCD protective devices
(type A) are permissible. Like frequency inverters, RCD protective
devices cannot provide personal safety while operating the device.
With open loop speed control using transformers or electronic volt-
age regulators (e.g. phase angle control), excessive current may
occur.
In addition, noises can occur with phase control, depending on the
manner in which the device is installed.
Fit sinusoidal filters that work on all poles (live-live and live-earth)
between the frequency inverter and the motor for operation with
frequency inverters.
WARNING
Device without overheating protection
The device is delivered without any automatically functioning overhe-
ating protection. The device can become hot and burn.
➜ For the version without TOP, install an additional, suitable motor
(Applicable only to devices without off-board TOPs)
CAUTION
Electrical voltage
The device is a built-in component and features no electrically isolat-
ing switch.
➜ Connect the device only to circuits that can be switched off using
➜ When working on the device, you must switch off the sys-
(Applicable only to devices with off-board TOPs)
The motors are equipped with thermal overload protectors to protect
the devices.
Check to make sure that the thermal overload protector is correctly
connected before each operation.
Failure to connect up the thermal overload protector correctly will
invalidate your right to claim damage for any defects. (Applicable
only to devices with off-board TOPs)
WARNING
Terminals and connections have voltage even in a unit that is
shut off
Electric shock
➜ Wait five minutes after disconnecting the voltage at all poles
protection switch.
an all-pole disconnecting switch.
tem/machine in which the device is installed and secure it from
being switched on again.
before touching the unit.
3.3 Checking the connections
➜ Ensure that the power is off.
➜ Secure it from being switched on again.
➜ Check the correct fit of the connecting cables.
3.4 Switching on the device
➜ Inspect the device for visible external damage and the proper function of the
➜ Apply the nominal voltage to the voltage supply.
3.5 Switching off the device
➜ Separate the device from the supply voltage.
protective features before switching it on.
WARNING
Electric voltage on cable gland
Electric shock
➜ Do not use plastic terminal boxes with metal cable glands.
WARNING
Hot motor housing
Fire hazard
➜ Ensure that no combustible or flammable materials are located
in the vicinity of the fan.