SI2415-C-FT Silicon Laboratories Inc, SI2415-C-FT Datasheet - Page 21

no-image

SI2415-C-FT

Manufacturer Part Number
SI2415-C-FT
Description
Modem Chip Chipset 56Kbps 24-Pin TSSOP
Manufacturer
Silicon Laboratories Inc
Datasheets

Specifications of SI2415-C-FT

Package
24TSSOP
Main Category
Chipset
Sub-category
ISOmodem
Maximum Data Rate
56 Kbps
Transmission Media Type
Wire
Typical Operating Supply Voltage
3 V
Power Supply Type
Digital
Typical Supply Current
80 mA
Maximum Operating Supply Voltage
3.6 V
Mfg Application Notes
SI2493/57/34/15/04, Appl Note AN93
Data Format
V.21, V.22, V.23, V.29, V.32, Bell 103, Bell 212A
Baud Rates
14.4k
Interface
Parallel, UART
Voltage - Supply
3 V ~ 3.6 V
Mounting Type
Surface Mount
Package / Case
24-TSSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
SI2415-C-FTR
Quantity:
2 409
$
A
A/
Dn
En
E0
E1
Hn
H0
Command
Table 10. Basic AT Command Set (Command Defaults in Bold)
Display AT command mode settings.
Answer incoming call
Re-execute last command. This is the only command not preceded by “AT” or followed by a
<CR>.
Dial
The dial command, followed by 1 or more dial command modifiers, manually dials a phone
number:
Local DTE echo
Disable
Enable
Hook switch.
Go on-hook (hang up modem).
Modifier
! or &
, or <
@
W
G
P
T
L
;
Rev. 1.1
Function
Flash hook switch for FHT (U4F) ms (default: 500 ms)
Pause before continuing for S8 seconds (default:
2 seconds)
Return to AT command mode
Wait for silence.
Polarity reversal detect. By placing the “G” character in
the dial string (i.e. ATDTG1), the Si2457/34/15/04 will
monitor the telephone line for polarity reversals. If a
busy tone is detected, the Si2457/34/15/04 will report
“POLARITY REVERSAL” if a polarity reversal was
detected or “NO POLARITY REVERSAL” if a polarity
reversal was not detected. In each case, the result
code is followed by “OK”. If the S7 timeout occurs
before a busy tone is detected, the Si2457/34/15/04 will
report “NO CARRIER”. Polarity reversal monitoring
begins after the last digit is dialed and ends when the
busy tone is detected or S7 timeout occurs.
Note: It is not possible to establish a modem connection
Redial last number.
Pulse (rotary) dialing—pulse digits: 0, 1, 2, 3, 4, 5, 6, 7,
8, 9
Tone (DTMF) dialing—DTMF digits: *, #, A, B, C, D, 0,
1, 2, 3, 4, 5, 6, 7, 8, 9.
Wait for dial tone before continuing for S14 seconds
(default: 12 seconds). Blind dialing modes X0, X1 and
X3 do not affect the W command.
If the DOP bit (U7A, bit 7) is set, the “ATDTW” com-
mand will cause the ISOmodem® to pause dialing and
either report an “OK” if a dialtone is detected or “NO
DIALTONE” if a dial tone is not detected.
Action
when using this command.
Si2457/34/15/04
21

Related parts for SI2415-C-FT