770-6012 EAO, 770-6012 Datasheet - Page 6

Magnetic Tranducer

770-6012

Manufacturer Part Number
770-6012
Description
Magnetic Tranducer
Manufacturer
EAO
Datasheet

Specifications of 770-6012

Length
18mm
External Width
24mm
Length/height, External
18mm
Supply Voltage
12V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Mounting Instruction
The indicator is mounted in a fascia/control panel in two steps:
1. Insert indicator from back side in fascia/control panel
2. Snap on bezel and tighten fixing nut
2
Lens
The press ring is fitted between gland and lens. The seal is effective when the lens is snapped into place.
The switch is mounted in a fascia or control panel in three steps:
1. Detach front section just in released position, as in drawing
2. Insert switch from back side in fascia/control panel
3. Snap on front section and tighten fixing nut
Important for IP 65
With models to IP 65, the sealing ring 1) is already fitted
This must be removed if the SWISSTAC emergency
Stop identity plate (IP 65 model) is used.
Zero position
indicator 30 - 70 mm
indicator 30 - 70 mm sealing gland, -ring and press ring
emergency stop switch turn to release 55 - 70 mm
586
01.2002
Identity plate
Bezel
Wiring diagram
Indicator
Sealing ring2) is fitted as standard
in models to IP 65.
Swisstac

Related parts for 770-6012