85100036 Crouzet USA, 85100036 Datasheet - Page 2

SAFETY RELAY, KNA3-XS 24VAC-DC

85100036

Manufacturer Part Number
85100036
Description
SAFETY RELAY, KNA3-XS 24VAC-DC
Manufacturer
Crouzet USA
Series
KNA3-XSr
Datasheet

Specifications of 85100036

Relay Type
Safety
Contact Form
3PST (3 Form A)
Contact Rating (current)
6A
Switching Voltage
440VAC - Max
Coil Voltage
24VAC/DC
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Circuit
3PST (3 Form A)
Contact Rating @ Voltage
6A @ 250VAC
Current, Rating
6 A
Dielectric Rating
2.95 kV According to CEI 664-1
Dimensions
203 mm L x 22.5 mm W x 90 mm H
Function
Safety
Standards
UL
Temperature, Operating, Maximum
50 °C
Temperature, Operating, Minimum
0 °C
Voltage, Control
24 VAC/VDC
Voltage, Rating
250 VAC
Coil Voltage Vac Nom
24V
Coil Voltage Vdc Nom
24V
Contact Current Max
6A
Contact Voltage Ac Nom
250V
Contact Configuration
3PST-NO / SPST-NC
No. Of Poles
4
Relay Mounting
DIN Rail
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Coil Type
-
Coil Current
-
Control On Voltage (max)
-
Control Off Voltage (min)
-
Lead Free Status / Rohs Status
 Details
Control devices :
Depending on the degree of safety required, KNA3-XS can receive the
following components as inputs :
- emergency stop pushbuttons with one or two contacts (A1-A2)
- position sensors (limit switches) with one or two contacts (A1-A2)
- pushbutton for start or validation (Y1-Y2)
A positive break operation device must be used if a single channel is
used. (diagram 1)
To increase the degree of safety, one "N/C" auxiliary contact per power
contactor is wired in series with the start (or validation) pushbutton, to
ensure self-checking in this part of the installation. (diagram 2)
Examples of use
Emergency stop
Dimensions
24 V
KNA3-XS wired as category 2
118
113
channel without return loop
Control device with one
90
0V
KNA3-XS wiring
Diagram 1
13 23 33
13
A1 Y1 Y2
A2
14 24 34
14 24 34
C1
23
41
Two coils per
contact
33
42
C2
Validation
22,5
+0,5
–0
11/7
Mounting - Removing
Control devices :
The KNA3-XS has three "N/O" safety contacts (13-14/23-24/33-34) and one
"N/C" signalling contact (41-42). One or more control devices may be wired
(diagram 1 and 2) up to the breaking capacity of the safety contacts : 1500
VA. However, to limit internal heating in the KNA3-XS, it is advisable not to
exceed 10 A thermal for all three contacts. The signalling contact cannot be
used as a safety contact. The signalling contact can be wired on a PLC input
or integrated into a fault signalling system.
Extending the number of contacts :
The number of contacts of the KNA3-XS can be extended and the breaking
capacity thus increased. To do this, use the KZE3-XS (see page 11/20).
0V
Emergency stop
24 V
KNA3-XS wired as category 3
channels with return loop
Control device with two
Diagram 2
13 23 33
A1 Y1 Y2
A2
13
14 24 34
14 24 34
C1
23
41
33
42
C2
One coil per
contact
Validation
C1
C2
11