36MT120 Vishay, 36MT120 Datasheet - Page 3

RECT BRIDGE 3-PHA 1200V 35A D-63

36MT120

Manufacturer Part Number
36MT120
Description
RECT BRIDGE 3-PHA 1200V 35A D-63
Manufacturer
Vishay
Datasheets

Specifications of 36MT120

Voltage - Peak Reverse (max)
1200V
Current - Dc Forward (if)
35A
Diode Type
Three Phase
Speed
Standard Recovery >500ns, > 200mA (Io)
Mounting Type
QC Terminal
Package / Case
D-63
Product
Three Phase Bridge
Peak Reverse Voltage
1200 V
Forward Continuous Current
500 A
Max Surge Current
475 A
Forward Voltage Drop
1.19 V
Maximum Reverse Leakage Current
100 mA
Power Dissipation
0.35 W
Maximum Operating Temperature
+ 150 C
Length
28.5 mm
Width
28.5 mm
Height
10 mm
Mounting Style
Stud
Minimum Operating Temperature
- 55 C
No. Of Phases
Three
Repetitive Reverse Voltage Vrrm Max
1.2kV
Forward Current If(av)
35A
Forward Voltage Vf Max
1.19V
Operating Temperature Range
-55°C To +150°C
Phase Type
Three Phase
Number Of Elements
1
Peak Rep Rev Volt
1.2kV
Peak Non-repetitive Surge Current (max)
500A
Avg. Forward Curr (max)
35A
Rev Curr
200uA
Operating Temp Range
-55C to 150C
Pin Count
5
Mounting
Through Hole
Operating Temperature Classification
Military
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Reverse Recovery Time (trr)
-
Lead Free Status / Rohs Status
Compliant
Other names
*36MT120
VS-36MT120
VS-36MT120
VS36MT120
VS36MT120

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
36MT120
Manufacturer:
VIR
Quantity:
6
Part Number:
36MT120
Manufacturer:
IR
Quantity:
6
Part Number:
36MT120
Manufacturer:
PRX
Quantity:
726
Part Number:
36MT120
Manufacturer:
VISHAY/威世
Quantity:
20 000
www.irf.com
Ordering Information Table
Thermal and Mechanical Specifications
Outline Table
T
T
R
R
wt
T
J
stg
thJC
thCS
Not To Scale
Parameters
Max. junction temperature range
Max. storage temperature range
Max. thermal resistance
junction to case
Max. thermal resistance, case to
heatsink
Approximate weight
Mounting Torque ± 10%
1
2
3
Device Code
-
-
-
Current rating code:
Basic part number
Voltage code ( code x 10 = V
26MT
1.42
0.2
-55 to 150
-55 to 150
36
1
2.0
20
36MT Units
1.35
0.2
MT
2
K/W
K/W
o
o
Nm
C
C
g
All dimensions in millimeters (inches)
Suggested plugging force:
400 N max; axially applied to faston terminals
160
3
Conditions
DC operation per bridge
(Based on total power loss of bridge)
Bridge to heatsink with screw M4
RRM
Mounting surface, smooth, flat and greased
26 =
36 =
)
25A (Avg)
35A (Avg)
26MT../36MT.. Series
Bulletin I2771 rev. G 09/06
3

Related parts for 36MT120