Specifications of F4804A-R

Operating Temperature Min Deg. C
-40C
Operating Temperature Max Deg. C
85C
Rad Hardened
No
Lead Free Status / RoHS Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
F4804A-R
Manufacturer:
PULSE
Quantity:
20 000
Part Number:
F4804A-RG
Manufacturer:
Bel
Quantity:
131
Part Number:
F4804A-RG
Manufacturer:
PULSE
Quantity:
20 000
Applications
Differential and Common Mode filtering for DC-DC
converters with 48 V and 24 V input:
• Telecommunications
• Data communications
• Distributed Power Solutions
Description
The F4804 Input Filter minimizes the conducted and radiated emissions generated by switch mode DC-DC
converters, and allows board designs utilizing
emissions requirements.
Using the F4804 filter as the primary power-conditioning device in front of any of the
provide a “worry-free” EMI design. Unlike most available off-the-shelf filter modules, the F4804 contains, in
addition to common mode noise reduction components, a differential LC-filter stage, which guarantees compliance
with conducted noise standards in the whole frequency range from 150 kHz to 30 MHz, including fundamental
switching frequency and its harmonics. Test results show headroom of 15-20 dB for conducted noise quasi-peak
levels, in relation to Class B requirements; see Figs. 2-8.
F4804 filter is designed specifically for distributed power solutions in conjunction with
converters. Low profile and small size (only 0.75 sq. in.) in a surface mount package helps the system designer
save real estate on the system board, and simplifies the layout.
A single F4804 filter can be used with multiple converters, and is capable of providing up to a nominal 4 A to the
converter input bus. It can provide up to 3 A at 85°C ambient with no airflow.
REV. June 01, 2005
Q & &
™ Family converters to easily meet stringent Class B conducted
Page 1 of 10
Features
• Maximum current 4 A
• Maximum operating input voltage 80V
• 100V/50V 100ms transient withstand capability
• Differential LC-filter stage
• Surface mounted design
• Small footprint – only 0.75 sq. in.
• Low profile: 0.339” [8.61 mm] maximum
• Low weight: 0.18 oz [5 g]
• -40°C to 85°C ambient temperature range
• No airflow required up to 3 A current @ 85°C
• Enables
• UL 60950 recognition in U.S. & Canada, and
• RoHS compliant (Q4 2005)
EN55022 and FCC Class B requirements conducted
emissions
DEMKO certification per IEC/EN 60950
F4804 Input Filter Data Sheet
Q & &
™ Family converter compliance with
80Vdc @ 4A Output
www.power-one.com
Q & &
™ Family converters will
Q & &
™ Family DC-DC
di/dt
®

Related parts for F4804A-R

F4804A-R Summary of contents

Page 1

Applications Differential and Common Mode filtering for DC-DC converters with 48 V and 24 V input: • Telecommunications • Data communications • Distributed Power Solutions Description The F4804 Input Filter minimizes the conducted and radiated emissions generated by switch mode ...

Page 2

Electrical Specifications Conditions: T =25ºC, No Airflow, Vin=48 Vdc, unless otherwise specified. A Parameter Absolute Maximum Ratings 1 Input Voltage Operating Ambient Temperature Storage Temperature Electrical Characteristics 1, 2 Operating Input Voltage Range Maximum Operating Current Voltage Drop at Maximum ...

Page 3

F4804 Input Filter (Top View) Vsource -IN Fig. 1: Typical F4804 application schematic with logic). Values C1, C2 and Cin depend on the specific converter input and output voltage. Fig. 2: Conducted emissions plot (quasi-peak values: "x", average ...

Page 4

Fig. 3: Conducted emissions plot (quasi-peak values: "x", average values: "+") for Q48x30025 in conjunction with F4804 filter. Limits shown are for quasi-peak (upper limit) and average (lower limit) values 2200 pF 3300 pF, Cin = ...

Page 5

Fig. 4: Conducted emissions plot (quasi-peak values: "x", average values: "+") for Q48x30020 in conjunction with F4804 filter. Limits shown are for quasi-peak (upper limit) and average (lower limit) values 2200 pF 3300 pF, Cin = ...

Page 6

Fig. 5: Conducted emissions plot (quasi-peak values: "x", average values: "+") for Q48x30018 in conjunction with F4804 filter. Limits shown are for quasi-peak (upper limit) and average (lower limit) values 2200 pF 3300 pF, Cin = ...

Page 7

Fig. 6: Conducted emissions plot (quasi-peak values: "x", average values: "+") for Q48x30015 in conjunction with F4804 filter. Limits shown are for quasi-peak (upper limit) and average (lower limit) values 2200 pF 3300 pF, Cin = ...

Page 8

Fig. 7: Conducted emissions plot (quasi-peak values: "x", average values: "+") for Q48x15050 in conjunction with F4804 filter. Limits shown are for quasi-peak (upper limit) and average (lower limit) values (not mounted 1500 pF, ...

Page 9

Fig. 8: Conducted emissions plot (quasi-peak values: "x", average values: "+") for Q48x08120 in conjunction with F4804 filter. Limits shown are for quasi-peak (upper limit) and average (lower limit) values (not mounted 1500 pF, ...

Page 10

Physical Information (Actual size shown) TOP VIEW +IN -IN SIDE VIEW Filter Part Numbering Ordering Information Product Input Series Voltage F 48 ≤ Filter Module The example above describes P/N F4804-RG: 0-80 V input ...