70001 ACME ELECTRIC, 70001 Datasheet - Page 14

Toroidal Transformer

70001

Manufacturer Part Number
70001
Description
Toroidal Transformer
Manufacturer
ACME ELECTRIC
Datasheet

Specifications of 70001

Power Rating
1.6VA
Secondary Voltages
2 X 9V
Secondary Current Nom
1mA
Transformer Mounting
PC Board
Weight
82g
Transformer Type
Toroidal
Secondary Current Aac
89mA
Output Current, Secondary Series
89mA
Frequency
60Hz
Output Current
89mA
Rohs Compliant
Yes
Primary Voltages
2 X 115V
Mounting Type
PC Board
Features
Low Profile
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
700013
Manufacturer:
MICREL
Quantity:
6 230
Part Number:
700018211
Quantity:
5 510
Part Number:
700018211
Quantity:
5 510
Part Number:
70001AB
Manufacturer:
ST
0
Part Number:
70001AR
Manufacturer:
ST
0
Part Number:
70001CC
Quantity:
5 510
Part Number:
70001CC
Quantity:
5 510
Part Number:
70001RR
Manufacturer:
ST
0
Company:
Part Number:
70001SB
Quantity:
2 400
Frequently, in applications calling for simple voltage step-up or step-down,
and where there is no requirement for electrical isolation, applying an
autotransformer will result in significant size and weight reductions as well
as cost. The power rating of an autotransformer is given by the expression:
P
V
V
A rule of thumb to apply when considering an autotransformer is that
the voltage across the entire winding should be less than or equal to
two times (2x) the value of the lowest voltage tap (V
rated
low
hi
= P
= voltage from lower voltage tap (input or output)
= voltage across higher voltage tap (output or input)
1500VA Isolation Transformer and 1500VA Autotransformer
out
x (V
STEP DOWN AUTOTRANSFORMER
STEP UP AUTOTRANSFORMER
hi
AUTOTRANSFORMERS YIELD
REDUCED SIZE AND COSTS
- V
low
)/V
hi
COMPLIMENTARY PRODUCTS
hi
< 2V
(800) 527-7042
low
).
www.amveco.com
3-Phase toroidal transformers are simply three separate single phase
units. When convenient, they may be mounted as individual units, adding
flexibility to the design of the housing or, in many cases, stacked together
side by side or stacked on top of each other. For higher powered units,
the relative assembly labor is less using toroids where each phase may be
handled separately (usually by one person). Compare this to E-I trans-
former installations where a large single unit must be moved (requiring
several workers and a hoist).
3-Phase Toroidal Array Mounted in Flanges with Terminal Blocks
3-PHASE TRANSFORMERS
12

Related parts for 70001