120T1-433F RF Solutions, 120T1-433F Datasheet - Page 7

TRANSMITTER, 1SW, FM, KEYFOB

120T1-433F

Manufacturer Part Number
120T1-433F
Description
TRANSMITTER, 1SW, FM, KEYFOB
Manufacturer
RF Solutions
Datasheets

Specifications of 120T1-433F

Svhc
No SVHC (15-Dec-2010)
External Depth
16mm
External Length / Height
66mm
External Width
34mm
Frequency
433.92MHz
Operating Temperature Max
60°C
Operating Temperature Min
0°C
Supply Voltage
12V
Rohs Compliant
Yes
Accessory Type
FM Keyfob 1 Switch
DS010-6 May 06
Serial Data is sent as a stream of ASCII characters at 9.6K baud. The character format is 8 data bits
with 1 stop bit, no parity.
A serial data string is output every time a valid transmitter packet is received. Due to the nature of
the KeeLoq packet there will be a minimum gap between each serial data string of 150mSec.
The Transmitter Serial Number : is made up of 7 ASCII characters from the following group: 0 1 2
3 4 5 6 7 8 9 A B C D E F. The most significant serial number digit is transmitted first. This provides
a total of 28million possible serial numbers.
Serial Data Format
10 characters are sent with the following format;
The KeeLoq Button Status is transmitted as an ASCII character in the range A to O or if the low battery
bit is asserted (encoder battery is low) then in the range a to o. KeeLoq data bits S0, S1, S2 and S3 then
make up the ASCII byte least significant bits D0, D1, D2 and D3.
If a single encoder button is pressed, say S0, then character A will be sent (or if low battery, a).
If encoder button S1 is pressed then B (or b) will be sent.
If S0 and S1 are both pressed simultaneously then character C (or c) will be sent.
If all KeeLoq encoder buttons are simultaneously pressed then character O (or o) will be sent.
Examination of the ASCII bit patterns shows that this allows single or multiple encoder button presses to
be decoded by the ASCII receiving device.
Examples of Serial Data output:
For a three button keyfob with serial number 2345678, the serial data output when encoder transmission is
decoded would be as follows:
If S1 is pressed: 2345678A (2345678a if the battery voltage in the transmitter is low)
If S2 is pressed: 2345678B (2345678b if the battery voltage in the transmitter is low)
If S1 and S2 are pressed together: 2345678C (2345678c if the battery voltage in the transmitter is low)
If S4 is pressed: 2345678H (2345678h if the battery voltage in the transmitter is low)
7
6
RF R
5
Output from SD1 pin
4
ECEIVER
©2006 REG No 277 4001, England.
3
2
1
D
A(a)
ECODER
$ 0D $0A
H
10 bytes of data transmitted
YBRID
Line feed (last character)
Carriage return
Transmitter button information
with battery status
Transmitter serial number
Page 7
.
HIRK-315
HIRK-433
HIR6-433

Related parts for 120T1-433F