DG528BK Vishay, DG528BK Datasheet
DG528BK
Available stocks
Related parts for DG528BK
DG528BK Summary of contents
Page 1
... ATE. DG528 PLCC Latches V– GND Decoders/Drivers Top View DG528/529 Vishay Siliconix Data Acquisition Systems Automatic Test Equipment Avionics and Military Systems Medical Instrumentation DG529 Dual-In-Line GND Latches 3 16 V– V+ Decoders/Drivers Top View www.vishay.com FaxBack 408-970-5600 5-1 ...
Page 2
... Part Number Temp Range DG528CJ – DG528DN –55 to 125 C DG528BK DG528AK DG528AK/883 5962-8768901VA Power Dissipation (Package) 18-Pin Plastic DIP 18-Pin CerDIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 3
... –0.002 –10 –10 –30 –30 0 1 300 300 180 180 500 500 www.vishay.com FaxBack 408-970-5600 5-3 ...
Page 4
... V – Drain Voltage (V) D Input Switching Threshold vs. V+ and V– Supply Voltages 2 2.0 1.5 1.0 0 V+, V– Positive and Negative Supplies (V) www.vishay.com FaxBack 408-970-5600 5-4 Test Conditions Unless Otherwise Specified V– = – V– = – 2 2 Temp IN Room ...
Page 5
... The WR pin is used to transfer the state of the address control lines to their latches, except during a reset or when EN is low (see Truth Tables Switch Output 80% 0 DG528/529 Vishay Siliconix V– signals are level shifted and X 50 OFF (RS) 80% FIGURE 3. www.vishay.com FaxBack 408-970-5600 5-5 ...
Page 6
... – DG528 GND WR V– 50 – – and DG529 GND WR V– 50 –15 V www.vishay.com FaxBack 408-970-5600 5-6 Logic Input + Switch Output FIGURE 4. Break-Before-Make Logic Input 300 Switch Output 300 FIGURE 5. Transition Time t < < 50 80% t OPEN <20 ns ...
Page 7
... Document Number: 70068 P-32167—Rev. C, 15-Nov-93 S – Logic Input 35 pF 300 Switch Output – 300 FIGURE 6. Enable t /t Time ON OFF + Switch V O Output FIGURE 7. Write Turn-On Time t ON(WR) DG528/529 Vishay Siliconix t < < 50 ON(EN) OFF(EN) 90% O 50% t ON(WR) 20% www.vishay.com FaxBack 408-970-5600 5-7 ...
Page 8
... DG528/529 Vishay Siliconix + +2 Remaining Switches DG528 DG529 GND WR V– 300 W –15 V Processor RESET System Bus WRITE Address Bus www.vishay.com FaxBack 408-970-5600 5 Switch Output FIGURE 8. Reset Turn-Off Time t OFF(RS) + Data Bus DG528 Address Decoder D V– – FIGURE 9. Bus Interface 50% ...
Page 9
... EN latches is decoded and the appropriate switch is turned on. The EN latch allows all switches to be turned off under program control. This becomes useful when two or more DG528s are cascaded to build 16-line and larger multiplexers. DG528/529 Vishay Siliconix Analog Voltage S D Range ( www.vishay.com FaxBack 408-970-5600 5-9 ...
Page 10
... Information contained herein is intended to provide a product description only. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Vishay's terms and conditions of sale for such products, Vishay assumes no liability whatsoever, and disclaims any express or implied warranty, relating to sale and/or use of Vishay products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright, or other intellectual property right ...