N9010AK-MSE AGILENT TECHNOLOGIES, N9010AK-MSE Datasheet

no-image

N9010AK-MSE

Manufacturer Part Number
N9010AK-MSE
Description
EXA Signal Analyzer N9010A
Manufacturer
AGILENT TECHNOLOGIES
Datasheet

Specifications of N9010AK-MSE

Connection Method
USB
Computer Connector
USB
For Use With
N9010A EXA Signal Analyzers
Lead Free Status / RoHS Status
na
N9010A EXA
X-Series Signal Analyzer
9 kHz to 3.6, 7.0, 13.6, or 26.5 GHz
Data Sheet

Related parts for N9010AK-MSE

N9010AK-MSE Summary of contents

Page 1

N9010A EXA X-Series Signal Analyzer 9 kHz to 3.6, 7.0, 13.6, or 26.5 GHz Data Sheet ...

Page 2

Table of Contents Definitions and Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

Page 3

Defi nitions and Conditions Specifications describe the performance of parameters covered by the product warranty and apply to the full temperature °C noted. 95th percentile values indicate the breadth of the population (approx. 2 σ) of ...

Page 4

Frequency and Time Specifi cations Frequency range Option 503 Option 507 Option 513 Option 526 Band LO multiple ( Frequency reference Accuracy Aging rate Temperature stability 20 to ...

Page 5

Sweep time and triggering Range Accuracy Trigger Trigger Delay Time gating Gate methods Gate length range (except method = FFT) Gate delay range Gate delay jitter Sweep (trace) point range All spans Resolution bandwidth (RBW) Range (–3.01 dB bandwidth) Bandwidth ...

Page 6

Amplitude Accuracy and Range Specifi cations Amplitude range Measurement range Input attenuator range (9 kHz to 26.5 GHz) Standard Option FSA Electronic attenuator (Option EA3) Frequency range Attenuation range Electronic attenuator range Full attenuation range (mechanical + electronic) Maximum safe ...

Page 7

Input attenuation switching uncertainty Attenuation > preamp off 50 MHz (reference frequency) Relative kHz to 3.6 GHz (reference setting) 3.5 to 7.0 GHz 6.9 to 13.6 GHz 13.5 to 26.5 GHz Total absolute ...

Page 8

Dynamic Range Specifi cations 1 dB gain compression (two-tone) 20 MHz to 26.5 GHz Preamp on 10 MHz to 3.6 GHz 3.6 to 7.0 GHz Displayed average noise level (DANL) (Input terminated, sample or average detector, averaging type = Log, ...

Page 9

Nominal Range at 1 GHz -60 -70 -80 -90 -100 -110 -120 -130 -80 -70 -60 -50 -40 -30 -20 -10 Mixer Level (dBm) Nominal Dynamic Range Bands 1-4 -60 -70 -80 -90 -100 -110 -120 -130 -80 -70 -60 ...

Page 10

Phase noise Offset Noise sidebands 100 Hz ( ° GHz) 1 kHz 10 kHz 100 kHz 1 MHz 10 MHz 1. For nominal values, refer to Figure 3. Figure 3. Nominal phase noise at ...

Page 11

PowerSuite Measurement Specifi cations Channel power Amplitude accuracy, W-CDMA or IS95 ( °C, attenuation = 10 dB) Occupied bandwidth Frequency accuracy Adjacent channel power Accuracy, W-CDMA (ACLR) (at specific mixer levels and ACLR ranges) MS BTS Dynamic range ...

Page 12

General Specifi cations Temperature range Operating Storage EMC Complies with European EMC Directive 2004/108/EC • IEC/EN 61326-1 or IEC/EN 61326-2-1 • CISPR Pub 11 Group 1, class A • AS/NZS CISPR 11:2002 • ICES/NMB-001 This ISM device complies with Canadian ...

Page 13

Inputs and Outputs Front panel RF input Connector Probe power Voltage/current USB 2.0 ports Master (2 ports) Standard Connector Output current Rear panel 10 MHz out Connector Output amplitude Frequency Ext Ref In Connector Input amplitude range Input frequency Frequency ...

Page 14

Rear panel GPIB interface Connector GPIB codes GPIB mode LAN TCP/IP interface Standard Connector IF output Connector Impedance Wideband IF output, Option CR3 Center frequency SA mode or I/Q analyzer with IF BW ≤ 25 MHz with Option B40 Conversion ...

Page 15

I/Q Analyzer Frequency Frequency span Standard instrument Option B25 Option B40 Resolution bandwidth (spectrum measurement) Range Overall Span = 1 MHz Span = 10 kHz Span = 100 Hz Window shapes Flat top, Uniform, Hanning, Gaussian, Blackman, Blackman-Harris, Kaiser Bessel ...

Page 16

IF phase linearity (deviation from mean phase linearity, nominal) Center frequency (GHz) ≤ 3.6 3.6 < f ≤ 26.5 3.6 < f ≤ 26.5 Data acquisition (10 MHz IF path) Time record length IQ analyzer 89600 VSA software or N9064A ...

Page 17

Option B40 40 MHz analysis bandwidth IF frequency response (B40 IF path) IF frequency response (demodulation and FFT response relative to the center frequency °C) Center frequency (GHz) 0.03 ≤ f < 3.6 3.6 ≤ f ≤ ...

Page 18

... Spain 34 (91) 631 3300 Sweden 0200- United Kingdom 44 (0) 118 9276201 For other unlisted countries: www.agilent.com/find/contactus Revised: October 14, 2010 Product specifications and descriptions in this document subject to change without notice. © Agilent Technologies, Inc. 2010 Printed in USA, December 23, 2010 5989-6529EN ...

Related keywords