AA1-B0-34-615-3D1-C Carling Technologies, AA1-B0-34-615-3D1-C Datasheet - Page 4

CIRCUIT BREAKER, HYD-MAG, 1P, 277V, 15A

AA1-B0-34-615-3D1-C

Manufacturer Part Number
AA1-B0-34-615-3D1-C
Description
CIRCUIT BREAKER, HYD-MAG, 1P, 277V, 15A
Manufacturer
Carling Technologies
Series
Ar
Datasheet

Specifications of AA1-B0-34-615-3D1-C

Input Voltage Vac
277V
No. Of Poles
1
Current Rating
15A
Interrupting Capacity
5kA
Dielectric Strength
1.5kV
Trip Time
20s
Voltage Rating Vdc
80V
Product Type
Circuit Breakers
Mounting Type
Push-On
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
www.carlingtech.com
Electrical
Maximum Voltage
Current Ratings
Standard Voltage Coils
Auxiliary Switch Rating
Insulation Resistance
Dielectric Strength
Resistance, Impedance
Pulse Tolerance Curves
277VAC 50/60 Hz, 80VDC
Standard current coils: 0.100, 0.250,
0.500, 0.750, 1.00, 2.50, 5.00, 7.50,
10.0, 15.0, 20.0, 25.0, 30.0, 35.0,
40.0, 50.0. Other ratings available -
consult ordering scheme.
DC-6V, 12V; AC-120V, Other ratings
available, consult ordering scheme.
SPDT; 10.1 A - 250VAC,
1.0 A-65VDC/0.5 A - 80 VDC,
0.1A - 125VAC (with gold contacts).
Minimum: 100 Megohms at 500 VDC
UL, CSA - 1500V 60 Hz for one
minute between all electrically isolat-
ed terminals. A-Series rocker circuit
breakers comply with the 8mm spac-
ing & 3750V dielectric requirements
from hazardous voltage to operator
accessible surfaces per EN 60950
and VDE 0805.
Values from Line to Load Terminal -
based on Series Trip Circuit Breaker.
Mechanical
Physical
Environmental
Endurance
Trip Free
Trip Indication
Number of Poles
Internal Circuit Configurations Series, (with or without auxiliary
Weight
Standard Colors
Designed and tested in accordance with requirements of specifi-
cation MIL-PRF-55629 & MIL-STD-202 as follows:
Shock
Vibration
Moisture Resistance
Salt Spray
Thermal Shock
Operating Temperature
A-Series – General Specifications
10,000 ON-OFF operations @ 6 per
minute; with rated Current & Voltage.
All A-Series Circuit Breakers will trip
on overload, even when the actuator
is forcibly held in the ON position.
The operating actuator moves posi-
tively to the OFF position when an
overload causes the circuit breaker
to trip. When mid-trip handle is spec-
ified, the handle moves to the mid
position on electrical trip of the cir-
cuit breaker. When mid-trip handle
with alarm switch is specified, the
handle moves to the mid position &
the alarm switch actuates when the
circuit breaker is electrically tripped.
1 - 6 Poles (handle) and 1-3 poles
(rocker) at 30 Amps or less. 1 and 2
poles at 31 Amps thru 50 Amps.
switch), Shunt and Relay with cur-
rent or voltage trip coils, Dual Coil,
Switch Only with or without auxiliary
switch.
Approximately 65 grams/pole.
(Approximately 2.32 ounces/pole)
Housing - Black; Actuator- See
Ordering Scheme.
Withstands 100 Gs, 6ms, sawtooth
while carrying rated current per
Method 213, Test Condition “I”.
Instantaneous and ultra-short curves
tested @ 90% of rated current.
Withstands 0.060" excursion from
10-55 Hz, and 10 Gs 55-500 Hz, at
rated current per Method 204C, Test
Condition A. Instantaneous and
ultrashort curves tested at 90% of
rated current.
Method 106D; ten 24-hour cycles @
+ 25°C to +65°C, 80-98% RH.56
days @ +85°C, 85% RH.
Method 101, Condition A (90-95%
RH @ 5% NaCl Solution, 96 hrs).
Method 107D, Condition A (Five
cycles @ -55°C to +25°C to +85°C
to +25°C).
-40° C to +85° C
37