PW-4130M TRUST, PW-4130M Datasheet - Page 2

no-image

PW-4130M

Manufacturer Part Number
PW-4130M
Description
UPS, POWERMASTER 1300VA, TRUST
Manufacturer
TRUST
Datasheet

Specifications of PW-4130M

Capacity (va / W)
1.3kVA / 600W
No. Of Outlets
4
Output Voltage
230V
Backup Time - Full Load
70min
Length
400mm
Width
145mm
Height
206mm
Weight Min
13.8kg
External Depth
400mm
Weight
9.6kg
Ac Power
1300VA
Battery Backup Time
70min
User’s manual
Safety
• Warning: This product contains sealed lead-acid battery(s).
• This UPS generates leakage current less than 0.5mA, please use in comfort.
• The sum of the leakage current of the UPS and its connected equipments must not exceed 3.5mA.
• Do not open or repair this device.
• Disconnect the power plug from the mains supply before cleaning the device.
• Keep this device away from liquids, such as water.
• Do not use this device in combination with non-computer related items, such as medical equipment,
• Make sure the UPS is placed on a firm surface, such as your desk or the floor.
• ALWAYS use the UPS with an earthed plug socket.
• Do not connect a multiple socket to the UPS.
• Never cover the UPS to avoid overheating. Keep the UPS out of the reach of heat sources, such as the sun,
• The outputs may have a high voltage, even when the device is turned off.
• Keep the UPS at least 20 cm from your monitor.
• Do not expose the battery to a naked flame. This may cause the battery to explode.
• Never drill holes into the battery.
• The battery must not be opened or damaged. If the battery is opened or damaged, electrolyte may be
• When the battery is empty, ask your local authority where you can dispose of it.
• The fan in UPS may get dusty after using a while, please remove the AC input power and turn off the UPS
• Do not insert any object into the fan while it’s spinning which may lead to the broken of the fan, or damage
May release toxic materials into the environment when not disposed properly.
Must be recycled properly. Contact your local government.
Short circuit of the battery(s) may cause burns, fire or explosion.
Do not disassemble, puncture or expose to high temperatures. Acid and toxic materials might be released,
causing injury.
microwave ovens, vacuum cleaners, etc.
heaters, etc.
released, which is harmful to skin, eyes and the environment.
then use a soft brush gently clean off the dust for better ventilation of the UPS and longer product life.
of the UPS, or damage of the object being inserted.
Surge current protection [J]
Maximum surge current [Amp]
Transfer time (typical)
Battery
Surroundings
Weight
Battery type & number
Backup time (min.)
Charge time
Working surroundings
Sound level
6
8 hours to 90% after full discharge
0 – 40° C, 0-90% relative humidity
CSB GP1270(F2), 12V/ 7AH
Less than 3 ms
Max. 150
2 pieces
38 ~ 70
< 40 dB
6,500 A
13.8 kg