63-23-250-8 SOLA HEVI DUTY, 63-23-250-8 Datasheet

Voltage Regulator/Power Conditioner

63-23-250-8

Manufacturer Part Number
63-23-250-8
Description
Voltage Regulator/Power Conditioner
Manufacturer
SOLA HEVI DUTY
Series
MCRr
Datasheets

Specifications of 63-23-250-8

Suppressor Type
Power Line Conditioner
Input Voltage
480VAC
Output Voltage
120V
Width
330.2mm
Height
711.2mm
Output Voltage 3
240V
Output Type
Fixed
External Height
28"
Output Power
5000 VA
Input Voltage (nominal)
480 V
Features
Harmonic Filtering
Mounting Type
Surface Mount
Voltage Regulation
+/- 3 %
Voltage Regulation Accuracy
+/- 3 %
Brand/series
Hardwired Series
Capacity
5000 VA
Length
28.53 in.
Outline
B
Weight
222 lbs.
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Notes: For Outline “C”, the terminal block is located in the right unit. Use only the knockouts marked “X”.
63-23-112-4
63-23-125-4
63-23-150-8
63-23-175-8
63-23-210-8
63-23-215-8
63-23-220-8
63-23-230-8
63-23-250-8
63-28-275-8
63-28-310-8
63-28-315-8
All ratings depend on natural draft air circulation for cooling. They should not be mounted in confined or enclosed spaces unless
special provisions have been made for ventilation. The ambient air temperature around the MCR must not exceed 50°C. If an
enclosure is used, the Manufacturer should be consulted to make sure the enclosure will dissipate heat output of the MCR and
maintain an acceptable temperature.
* -C8 add .17 to “B”
CATALOG
NUMBER
OUTLINE “A”
For Outline “D”, the terminal block is located in the center unit. Use only the knockouts marked “X”.
10,000
15,000
1,000
1,500
2,000
3,000
5,000
7,500
VA
120
250
500
750
OUTLINE
A
A
A
A
A
B
B
B
B
C
C
D
Weights and Physical Dimensions (inches)
OUTLINE “B”
10.25
12.87
13.87
17.10
16.74
17.58
18.96
28.53
26.91
28.53
28.85
8.81
A
5.19
7.56
6.50
6.50
6.50
9.27
9.27
9.27
9.27
9.27
9.27
9.65
Phone: (800) 377-4384
FAX: (800) 367-4384
www.solaheviduty.com
B
10.56
10.56
10.56
10.56
23.55
23.55
35.56
3.47
4.75
8.12
8.12
8.12
Sola/Literature/Manuals/MCR Series/Mechanical Dimensions/MDMCR60 (12/02)
C
12.75
12.75
12.75
12.75
25.81
25.81
38.25
4.00
5.63
9.00
9.00
9.00
D
OUTLINE “C”
11.75
11.75
11.75
11.75
24.81
24.81
37.22
3.50
4.75
8.12
8.12
8.12
E
60 Hz MCR
Hardwired Series
Mechanical Dimensions
3.16
4.12
5.62
5.62
5.62
3.00
3.88
5.25
8.25
6.62
8.25
8.25
F
2.44
3.03
3.06
3.06
5.25
5.19
5.19
5.19
8.88
8.88
8.88
8.88
G
OUTLINE “D”
.22x.59
.31x.69
.38x.81
.38x.81
.38x.81
.44x.69
.44x.69
.44x.69
.44x.69
.44x.69
.44x.69
.56x.69
H
WEIGHT
(LBS)
109
142
222
362
446
710
15
27
37
52
62
95

Related parts for 63-23-250-8

63-23-250-8 Summary of contents

Page 1

... A 63-23-210-8 1,000 A 63-23-215-8 1,500 B 63-23-220-8 2,000 B 63-23-230-8 3,000 B 63-23-250-8 5,000 B 63-28-275-8 7,500 C 63-28-310-8 10,000 C 63-28-315-8 15,000 D All ratings depend on natural draft air circulation for cooling. They should not be mounted in confined or enclosed spaces unless special provisions have been made for ventilation. The ambient air temperature around the MCR must not exceed 50° enclosure is used, the Manufacturer should be consulted to make sure the enclosure will dissipate heat output of the MCR and maintain an acceptable temperature ...

Page 2

... A 63-32-220-8 2,000 B 63-32-230-8 3,000 B 63-29-250-8 5,000 B 63-29-275-8 7,500 C 63-29-310-8 10,000 C 63-29-315-8 15,000 D All ratings depend on natural draft air circulation for cooling. They should not be mounted in confined or enclosed spaces unless special provisions have been made for ventilation. The ambient air temperature around the MCR must not exceed 50° enclosure is used, the Manufacturer should be consulted to make sure the enclosure will dissipate heat output of the MCR and maintain an acceptable temperature ...