XCKP2106N12 SQUARE D, XCKP2106N12 Datasheet - Page 18

LIMIT SWITCH, 1NO/1NC, 240VAC, 250VDC, 10A

XCKP2106N12

Manufacturer Part Number
XCKP2106N12
Description
LIMIT SWITCH, 1NO/1NC, 240VAC, 250VDC, 10A
Manufacturer
SQUARE D
Datasheet

Specifications of XCKP2106N12

Actuator Style
Wobble Spring Wire
Operating Force Max
0.13N
Switch Operation
(ON)
Contact Voltage Ac Max
240V
Contact Voltage Dc Max
250V
Contact Current Ac Max
10A
Rohs Compliant
Yes
Limit Switches
Selection Guide
Osiswitch
18
Contact blocks (continued)
max.
21 - 22
13 - 14
0
1
2
P
21 - 22
13 - 14
21 - 22
13 - 14
0
1
2
P
max.
0
© 1997–2007 Schneider Electric All Rights Reserved
0
B
C
C
B
B
C
1
1
D
®
B
C
XC Product Overview
D
A
A
P
P
P
P
2
2
A
A
Tripping
and
Resetting
Resetting
Tripping
Functional diagrams of snap action contacts
Example: N/C + N/O
A—Maximum travel of the operator in mm or degrees.
B—Tripping travel of contact.
C—Resetting travel of contact.
D—Differential travel = B–C.
P—Point from which positive opening is assured.
Linear movement (plunger)
1—Resetting point of contact.
2—Tripping point of contact.
A—Maximum travel of the operator in mm.
B—Tripping travel of contact.
C—Resetting travel of contact.
D—Differential travel = B–C.
P—Point from which positive opening is assured.
Rotary movement (lever)
1—Resetting point of contact.
2—Tripping point of contact.
A—Maximum travel of the operator in degrees.
B—Tripping travel of contact.
C—Resetting travel of contact.
D—Differential travel = B–C.
P—Point from which positive opening is assured.
Functional diagrams of slow break contacts
Example: N/C + N/O break before make
A—Maximum travel of the operator in mm or degrees.
B—Tripping and resetting travel of contact 21-22.
C—Tripping and resetting travel of contact 13-14.
P—Point from which positive opening is assured.
Linear movement (plunger)
1—Tripping and resetting points of contact 21-22.
2—Tripping and resetting points of contact 13-14.
A—Maximum travel of the operator in mm.
B—Tripping and resetting travel of contact 21-22.
C—Tripping and resetting travel of contact 13-14.
P—Positive opening point.
Rotary movement (lever)
1—Tripping and resetting points of contact 21-22.
2—Tripping and resetting points of contact 13-14.
A—Maximum travel of the operator in degrees.
B—Tripping and resetting travel of contact 21-22.
C—Tripping and resetting travel of contact 13-14.
P—Positive opening point.
03/2007

Related parts for XCKP2106N12