T0-1-102/I1H+K-CI MOELLER, T0-1-102/I1H+K-CI Datasheet

SWITCH, PLASTIC, ENCL, 20A, 2POLE

T0-1-102/I1H+K-CI

Manufacturer Part Number
T0-1-102/I1H+K-CI
Description
SWITCH, PLASTIC, ENCL, 20A, 2POLE
Manufacturer
MOELLER
Series
T0r
Datasheet

Specifications of T0-1-102/I1H+K-CI

No. Of Poles
2
Contact Voltage Ac Max
690V
Contact Current Ac Max
20A
Svhc
No SVHC (18-Jun-2010)
Current Rating
20A
Power Rating
11kW
Switching Ac3 Power Max
6.5kW
Voltage
RoHS Compliant
Type: T0−1−102/I1
Article No.: 207061
Contact sequence
1
Ordering information
Design
Description
Main conducting paths No. of poles
Auxiliary contacts
Auxiliary contacts
Max. three−phase motor rating (per set
of 3 contacts) 50−60 Hz AC−3 400/415
V 50−60 Hz
Rated uninterrupted current
General
Standards
Lifespan, mechanical
Operations
P
I
u
N/O
kW
M
B
A
× 10
6
Surface mounting
Without auxiliary contacts
2
0
0
11
20
IEC/EN 60947, VDE 0660,
IEC/EN 60204, CSA, UL
Switch−disconnectors to
IEC/EN 60947−3
Load−break switches to
IEC/EN 60947−3
1

Related parts for T0-1-102/I1H+K-CI

T0-1-102/I1H+K-CI Summary of contents

Page 1

... Type: T0−1−102/I1 Article No.: 207061 Ordering information Design Description Main conducting paths No. of poles Auxiliary contacts Auxiliary contacts Max. three−phase motor rating (per set of 3 contacts) 50−60 Hz AC−3 400/415 V 50−60 Hz Rated uninterrupted current Contact sequence General Standards Lifespan, mechanical ...

Page 2

Maximum operating frequency Climatic proofing Ambient temperature Open Enclosed Mounting position Documentation Mechanical shock resistance (shock duration 20 ms) Contacts Rated operational voltage Rated impulse withstand voltage Overvoltage category/pollution degree Rated uninterrupted current open Enclosed Load−carrying capacity in intermittent operation, ...

Page 3

... V 690 V Star−delta AC−23A Motor load switches (main switches maintenance switches) 230 V 400 V 500 V Rated operational current control switch AC−15 230 V 400 V 500 V DC DC−1, Load−break switches L Rated operational current 3 1 × (0.75 – 1. × (0.75 – 1.5) M3 130 A ...

Page 4

... Applies to T0(3).../SVB: isolating characteristics to IEC/EN 60947 Ufor rated operational voltage up to 500 V AC Applies to rated uninterrupted current I contact: with T5−4−8344/I5 max For terminal capacity solid, stranded and flexible: T0(3), (6), (8)...: Maximum of 2 cross−section sizes −5 , < 1 fault in 100000 of the u ...

Page 5

... For type T8−3−8342/... the following applies: switching angle = 90° and flat connection = 1 busbar 25 × busbars 20 × 3 not included T0−1−.../EZ "Y T0−1−.../E + EZ−T0 + S−(SOND−)T0 For utilisation category AC−4 (extreme load: 100 % inching, reversing or plugging) The blocked rotor current of ...

Page 6

Dimensions Characteristic curve 6 ...

Page 7

... Moeller GmbH, Hein−Moeller−Str. 7−11, D−53115 Bonn E−Mail: catalog@moeller.net, Internet: www.moeller.net, http://catalog.moeller.net Copyright 2006 by Moeller GmbH. Subject to modifications. HPL−C2006GB−INT V2.3 7 ...

Related keywords