259 THOMAS & BETTS, 259 Datasheet

Electrical

259

Manufacturer Part Number
259
Description
Electrical
Manufacturer
THOMAS & BETTS
Datasheet

Specifications of 259

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Outer Diameter
75.413mm
Length
66.675mm
Body Material
Malleable Iron
External Diameter
75.413mm
Accessory Type
Squeeze Connector
Rohs Compliant
No
For Use With
Armored Cable And Flexible Metal Conduit
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
2590C0
Manufacturer:
ST
0
Part Number:
2590CO
Manufacturer:
ST
0
Part Number:
2590E
Manufacturer:
ISD
Quantity:
14
Part Number:
2590E
Quantity:
9
Part Number:
2590G
Manufacturer:
DALLAS
Quantity:
164
Part Number:
2590S
Manufacturer:
WSI
Quantity:
14
Part Number:
25914.123.211
Manufacturer:
TE
Quantity:
35 000
Part Number:
2592D2
Manufacturer:
ST
0
Part Number:
2592D2
Manufacturer:
ST
Quantity:
20 000
Part Number:
2593D1
Manufacturer:
ST
0
Part Number:
2593D3
Manufacturer:
ST
0
Part Number:
2594M-5.0
Manufacturer:
NS/国半
Quantity:
20 000
Armored Cable (Type AC) — Ref. NEC
Article 320
National Electrical Code defines type AC armored
cable as, “A fabricated assembly of insulated
conductors in a flexible metallic enclosure.”
ACT
AC
ACH
ACHH
ACU
“L”
Metal Clad Cable, Armored Cable and Flexible Metal Conduit
NOTE
The materials herein, whether relating to the National Electrical Code, the Underwriters Laboratories, Inc. listing, to industry practice or otherwise,
are not intended to provide all relevant information required for use and installation of our products. Refer to applicable codes, instructions and
industry specifications prior to installation or use.
Indicates an armored cable
employing conductors having
thermoplastic (Type T) insulation.
Indicates an armored cable
employing conductors having rubber
insulation of code grade.
Indicates an armored cable
employing conductors having rubber
insulation of the heat resistant
(75° C) grade.
Indicates an armored cable
employing conductors having rubber
insulation of the heat resistant
(90° C) grade.
Indicates an armored cable
employing conductors having rubber
insulation of latex grade.
Used as a suffix, it indicates that a
lead covering has been applied over
the conductor assembly.
Metal Clad Cable, Armored Cable and Flexible Metal
United States
Tel: 901.252.8000
Fax: 901.252.1354
800.816.7809
aluminum or copperclad aluminum conductors
with the following sizes and are rated for
600 volts or less:
bonding strip of copper or aluminum in intimate
contact with the armor for its entire length.
Armored cable can be used for both exposed
or concealed locations. With lead-covered
conductors (Type ACL), the cable can be
embedded in masonry or concrete and can be
used in damp locations or where exposed to oil.
where it will be subjected to physical damage or
corrosive fumes. Armored cable cannot be used
for direct burial in earth.
not permitted to be used in hoists or elevators,
storage battery rooms, any hazardous locations,
in commercial garages and in theaters or similar
locations.
with straps or staples without damaging
conductors and also limit the minimum bend
radius to 5 times the diameter of type AC cable.
Certain precautions are prescribed in code where
cable is installed through joist rafters or similar
wood members.
All armored cables may employ copper or
No. 14 AWG to No. 1 AWG Copper
No. 12 AWG to No. 1 AWG Aluminum
or Copperclad Aluminum
Type AC cables except ACL carry an internal
Armored cable is not permitted in locations
With minor exceptions, armored cable is also
Codes require that cable shall be supported
Canada
Tel: 450.347.5318
Fax: 450.347.1976
Technical Services
Tel: 888.862.3289
Conduit Fittings
is terminated, a fitting is required to protect
conductors from abrasion. In addition,
a bushing is required between the conductors
and armor. Design of fitting has to be such that
the insulating bushing is visible for inspection.
Bushing is not required with lead-covered cables
when properly installed.
permission from NFPA 70–2005, National
Electrical Code
Fire Protection Association, Boston, MA.
and complete information:
1. NEC Article 320…Armored Cable (Type AC
2. UL 4, ANSI C33.9…Safety Standards for
3. UL 514B, Safety Standards for Outlet Boxes
4. A-A-50552…Federal Specification. Fittings
5. NEMA FB-1…Standards Publication. Fittings
6. CEC Section 12-700…Wiring Methods
7. CSA C22.2 No. 51…Safety Standards for
8. CSA C22.2 No. 18…Safety Standards for
According to NEC 320 where armored cable
Portions of this section reprinted by
Please refer to the following for further details
Cable)
Armored Cable
and Fittings
for Cable, Power, Electrical and Conduit,
Metal, Flexible
& Supports for Conduit and Cable Assemblies
(Armored Cable)
Armored Cables
Outlet Boxes, Conduit Boxes and Fittings
®
, Copyright © 2004, National
www.tnb.com
A-149

259 Summary of contents

Page 1

Metal Clad Cable, Armored Cable and Flexible Metal Metal Clad Cable, Armored Cable and Flexible Metal Conduit Armored Cable (Type AC) — Ref. NEC Article 320 National Electrical Code defines type AC armored cable as, “A fabricated assembly of insulated ...

Page 2

Metal Clad Cable, Armored Cable and Flexible Metal Conduit Fittings Metal Clad Cable, Armored Cable and Flexible Metal Conduit — Flexible Metal Conduit — Ref. NEC Article 348 Flexible metal conduit can be used for exposed or concealed work in ...

Page 3

Metal Clad Cable, Armored Cable and Flexible Metal Armored Cable & Flexible Metal Conduit Connectors Application • Features • 3110 Series • • • • • • • RANGE 3110 Series Straight Connectors 3130 Series 90° Connectors United States Tel: ...

Page 4

Metal Clad Cable, Armored Cable and Flexible Metal Conduit Fittings Designed to resist vibration and strain! TITE-BITE ® Connectors — Nylon-Insulated • Steel or malleable iron construction • Tough, insulated lining and Tite-Bite design make these connectors a “must” when ...

Page 5

Metal Clad Cable, Armored Cable and Flexible Metal Steel or malleable iron. Available with or without insulated throat, this • Tite-Bite Steel or malleable iron construction ® connector line is by far the easiest and best to install when making ...

Page 6

... C 278-TB 4.370 3.200 281-TB 4.600 3.500 ** UL Listed for armored cable only. Fitting material steel. *** UL Listed for flexible metal conduit only. ...

Page 7

Metal Clad Cable, Armored Cable and Flexible Metal Armor-gripping saddle stays open by itself when cable is being inserted! Two-Screw Connectors • Formed steel body CAT. CABLE OPENING • Carefully round NO. MAX. bushing 3301-TB** .656 3312-TB .937 ** UL ...