CA12CLC08BP CARLO GAVAZZI, CA12CLC08BP Datasheet - Page 3

Proximity Sensor

CA12CLC08BP

Manufacturer Part Number
CA12CLC08BP
Description
Proximity Sensor
Manufacturer
CARLO GAVAZZI
Datasheet

Specifications of CA12CLC08BP

Supply Voltage Range Dc
10V To 40V
Sensor Housing
Cylindrical
Sensing Range Min
0.5mm
Sensor Input
Capacitive
Supply Voltage Max
40VDC
Sensing Range Max
12mm
Leaded Process Compatible
Yes
Switch Terminals
Cable
Supply Voltage Min
10VDC
Output Current Max
250mA
Sensor Output
PNP
Rohs Compliant
Yes
Features
Teach-in PB
Range
0.5-8mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CA12CLC08BP
Manufacturer:
Carlo gavazzi
Quantity:
500
Part Number:
CA12CLC08BPM1
Manufacturer:
Carlo gavazzi
Quantity:
500
CA, M12, DC, Teach-in
Teach-in Guide
Adjustment - Background
No target present
Press push-button >3 seconds until LED´s are flashing one time per second. The background will be calibrated when the
push-button is released during the following 3 seconds
LED - Green
LED - Yellow
Time (sec)
Adjustment - Object
Target present
Press push-button >6 seconds until LED´s are flashing two times per second. The object will be calibrated when the push-
button is released during the following 3 seconds
LED - Green
LED - Yellow
Time (sec)
Adjustment - NO - NC
Press push-button >9 sec. until LED´s are flashing three times per second. The status of NO-NC will toggle when the push-
button is released during the following 3 seconds
LED - Green
LED - Yellow
Time (sec)
Wiring Diagram
Specifications are subject to change without notice (12.11.04)
Push-button
Push-button
Push-button
Releasing the push-button after 12 sec. returns the sensor to factory settings.
0
0
0
BK
WH
(4)
1
1
(2)
1
I
LOAD
< 250mA
2
2
2
3
3
3
4
4
4
I
ALARM
Teach-in
5
5
5
BN+
BU-
< 20mA
(1)
(3)
6
6
6
7
The PNP- or NPN-load will automatically be
detected.
By means of the Teach-in wire, the functions
described in the Teach-in Guide can be set-
up.
It is possible to Teach-in more sensors at the
same time by connecting the WH-wires in
parallel to the common ”-” supply.
(#): Plug connections
Important: If alarm output (WH-wire) is
unused, it has to be terminated to +supply
7
7
8
8
8
9
9
9
10
10
10
11
11
11
12
12
12
13
13
13
3

Related parts for CA12CLC08BP