06MTL0025A Honeywell Sensing and Control, 06MTL0025A Datasheet

TRANSDUCER, LINEAR POSITION

06MTL0025A

Manufacturer Part Number
06MTL0025A
Description
TRANSDUCER, LINEAR POSITION
Manufacturer
Honeywell Sensing and Control
Datasheet

Specifications of 06MTL0025A

Transducer Function
Linear Position Transducer
Power Rating
0.2W
Operating Temperature Range
-40°C To +80°C
Length
55.52mm
Insulation Testing Voltage
1000Vrms
Insulation Resistance
500Mohm
Svhc
No
M
*5-95% of Theoretical Electrical Travel
**Minimum quantities may be required.
***LT only, 12 oz. (340 g) max. starting force
NOTE: Do not test using an Ohmeter on Rx 1 scale or other current devices.
Excessive wiper current can cause output error or damage.
Zero side load is recommended to achieve maximum life.
MODELS
MECHANICAL
Total Mechanical Travel
Starting Force
Shock
Vibration
Life
ELECTRICAL
Theoretical Electrical
Travel (in 1" increments)
Independent Linearity
Total Resistance
Resistance Tolerance
Operating Temperature
Resolution
Insulation Resistance
Dielectric Strength
Power Rating
Recommended Wiper Current
TECHNICAL SPECIFICATIONS
ODELS
LT/MLT •
26.7 to 255.3 mm (min)
1.05 to 10.05 in. (min)
1000 M @ 500 Vdc
(25.4 to 254.0mm)
electrical travel
electrical trave
0.25 Watt/in.
1000 /in.
1 to 10 in.
LT
20 g rms 5 Hz to 2 KHz (MLT only)
-40 to 80 C (-40 to 176 F)
One billion dither operations
LINEAR POSITION TRANSDUCER
50 g 11 ms half sine
1.0 oz (max)
1000 V rms
Infinite
<1 A
1.0%
20%
13.9 to 153.7 mm (min)
500 M @ 500 Vdc
.55 to 6.05 in. (min)
(12.7 to 152.4mm)
electrical travel
electrical travel
0.20 Watt/in.
1500 /in.
1/2 to 6 in.
MLT
DIMENSIONS
OPTIONS**
• Other resistance values
• Independent Linearity to .1%
• Water resistant seal***
• Three pin connector for MLT
DIMENSIONS
1 - 8 0 0 - 3 3 3 - D A T A
Travels > 1 inch*
.50 Dia.
(12.7)
xx.xx = inches
(xx.xx) = mm
Extended
(Red)
Wiper
Optional MLT connector
#26 AWG (65/44) 12" (305) long min.
(Color coded per schematic)
#28 jacketed cable 6" long, min.
Retracted
(Color coded per schematic)
(Black)
3 - Conductor cable
[Electrical travel +1.2" (30.48)]
Ground
(Black)
(8.0)
(4.3)
.32
.17
.375 Dia.
Housing length
(Electrical travel + 1.50 in.)
(9.53)
Connect to high impedance circuit
(Black)
Ground
(Orange)
V-out
SCHEMATIC DIAGRAM
Housing length
MLT Mating Connector
(Brown)
Connect to high impedance circuit
V-out
(6.35)
.25
SCHEMATIC DIAGRAM
.187 Dia.
(4.76)
(19.0)
.75
Thd x .50 in. long
#4-40 UNC-2A
Metric Shaft Adapter
.75 Retracted
(Red)
V-in
(19.05)
(3.17)
(1.6)
.063
.125
.125 Dia.
(12.7)
1.00 (Retracted)
(3.1)
.50
Shaft Extended
.125 Dia.
(25.4)
(3.1)
(Red)
V-in
(15.87)
(9.4)
.625
Shaft Extended
.37
xx.xx = inches
(xx.xx) = mm
#4-40 UNF-2B
#4-40 UNF-2B
M6 x 3 Thread
23

Related parts for 06MTL0025A

Related keywords