D10DNFPQ BANNER ENGINEERING, D10DNFPQ Datasheet - Page 8

Photoelectric Sensor

D10DNFPQ

Manufacturer Part Number
D10DNFPQ
Description
Photoelectric Sensor
Manufacturer
BANNER ENGINEERING
Type
Dual Discrete Outputr
Datasheets

Specifications of D10DNFPQ

Sensor Output
NPN
Sensor Input
Fiber Optic
Output Type
Transistor
Contact Current Max
150mA
Switch Terminals
Quick Connect
Body Style
Rectangular
Brand/series
Expert™
Cable Type
6-Pin Pico-Style QD
Current, Switching
150 mA
Function
Fiber Optic
Indicator
LCD
Ip Rating
IP50
Material, Casing
Black ABS⁄Polycabonate Alloy (Housing)
Material, Cover
Polycarbonate
Mounting Type
DIN Rail
Output
NPN
Primary Type
Photoelectric
Sensing Mode
Selectable
Technology
Photoelectric
Temperature, Operating
-20 to +55 °C
Termination
6-Wire Cable
Time, Response
50 μs, 200 μs, 1 ms, 2.5 ms
Voltage, Supply
24 VDC
Accessories Available
Cordsets and Plastic Fiber Optic Cable
Fiber Optic Sensor Type
Dual Discrete Output
Lead Free Status / Rohs Status
RoHS Exempt Product
• S ets a threshold slightly above the taught condition (see figure 9).
• A ny condition lighter than the threshold condition causes the output to change state.
• T hreshold position is adjustable using “+” and “-” buttons (see Manual Adjust, page 9)
• R ecommended for applications where only one condition is known, for example a stable dark
A single sensing condition is presented, and the sensor positions a threshold slightly above
the taught condition. When a condition lighter than the threshold is sensed, the output either
turns ON or OFF, depending on the Light/Dark Operate setting (see Sensor Setup, page 10.)
Dark SET and Light/Dark Operate Selection
Dark SET teaches the Output OFF condition and forces the sensor into Light Operate (LO)
mode. The sensor can be reconfigured to Dark Operate (DO) mode after the condition has
been taught (see Sensor Setup, page 10).
D10 Expert
8
background with varying lighter targets.
P/N 64154 rev. F
• P ress and hold
• P resent Output
• F ive-click
0.04 seconds ≤ “Click” ≤ 0.8 seconds
Static push button
> 2 seconds
T
OFF condition
Static push
button
T
T
Push Button
T
Dual Discrete Outputs
T T T
T
T
Single-Point Dark SET
T
T
T
T
T
T
T
• S ingle-pulse
• P resent Output
• F ive-pulse remote line
remote line
OFF condition
T
0.04 seconds ≤ T ≤ 0.8 seconds
T
T
Remote Line
T
T
T
T
T
T
T
T
T
T
T
T
• Display flashes “1st”
• Arrow icon turns red
• Display flashes “2nd”
• Arrow icon turns red
Threshold Condition Accepted
• Display flashes “sngl” then “dr” twice
• S ensor returns to RUN mode with new settings
• Arrow icon turns green
Threshold Condition Unacceptable
• Display flashes “fail” and returns to “1st”
• Arrow icon remains red
• A fter 60 seconds, sensor returns to RUN mode
(Arrow icon turns green) without changing
settings
T
T T T
T
T
T
T
T
T
T
Banner Engineering Corp.
T
www.bannerengineering.com • Tel: 763.544.3164
T
Figure 9. Single-Point Dark SET (Light
Figure 10. Dark SET Threshold Offset
(no signal)
(no signal)
Super High-Speed
High-Speed
High-Power
Super High-Power
T
Darkest
Darkest
threshold slightly above
the presented condition
T
Push Button
T
Mode
Remote
Sensor positions
Result
T
Output OFF
Output ON
T
Operate shown)
T
T
T
Presented
Condition
Threshold position
T
Manual Adjust
adjusted by
T
T
Minneapolis, MN U.S.A.
taught signal value)
Condition
Presented
Threshold Offset
T
(counts above
the presented condition
Output OFF
Output ON
30
22
9
6
Most Light
Most Light
(saturated
(saturated
signal)
signal)

Related parts for D10DNFPQ