OS-SS3 PANASONIC EW, OS-SS3 Datasheet

no-image

OS-SS3

Manufacturer Part Number
OS-SS3
Description
SLIT MASK 0.5X3MM FOR SH-31R/31G/33R
Manufacturer
PANASONIC EW
Datasheet

Specifications of OS-SS3

Rohs Compliant
YES
2010.11
ideas for life
panasonic-electric-works.net/sunx
Achieving low power consumption and high noise-resistance
World Standard
Upgraded to Increase Usability
Amplifi er Built-in
Compact Photoelectric Sensor
CX-400
Conforming to
EMC Directive
UL Recognition
SERIES
(Some models only)
Ver.2
Certifi ed

Related parts for OS-SS3

OS-SS3 Summary of contents

Page 1

World Standard Upgraded to Increase Usability Achieving low power consumption and high noise-resistance 2010.11 panasonic-electric-works.net/sunx Amplifi er Built-in Compact Photoelectric Sensor CX-400 SERIES Conforming to UL Recognition EMC Directive Ver.2 Certifi ed (Some models only) ...

Page 2

... Immersion (depth 0 m); Insulation resistance 20 MΩ/250 V disperse oil mists. Note: Yushiron and Yushiroken are registered trademarks of 1 Providing stable detection with low power consumption Includes an analog CMOS processor ASIC CX-41□/42□/49□ Test Oil JIS Standard ...

Page 3

Upgrade Reducing environmental burdens further Up to 60% less power consumption The CX-400 series achieves reductions in power consumption 60%, averaging 44% reduction when upgrading due to its unique design. These sensors reduce carbon emissions and ...

Page 4

... Strong against extraneous light and noise CX-491 Hardly affected by extraneous lights or noises, these sensors provide stable sensing. Two sensors can be mounted close together All models The interference prevention function lets two sensors of any type to be mounted close together precisely. ...

Page 5

... CX-483: 500 to 1,000 mm 19.685 to 39.370 in [with the RF-230 reflector at the optimum condition (Note)] Each object should pass across the beam at the center between the sensor and the reflector. ℓ : Length of cylindrical glasses t : Thickness of sensing object Note: The optimum condition is defined as the condition in which the sensitivity level is set such that the stability indicator just lights up when the object is absent ...

Page 6

... The bright spot makes beam axis alignment easy All models These sensors have a high luminance red spot that provides bright visibility. The sensing position can be checked at a glance. Because the CX-441 sensor has a small spot beam, at approx. ø2 mm ø0.079 in, even the minutest object can be accurately detected ...

Page 7

... BGS / FGS functions make even the most challenging settings possible! The BGS function is best suited for the following case Background not present BGS When object and background are separated Not affected if the background color changes or someone passes behind the conveyor. BGS (Background suppression) function The sensor judges that an object is present when light is received at position A of the light-receiving element (2-segment element) ...

Page 8

ORDER GUIDE Standard type Type Appearance NOTE: Mounting bracket is not supplied with the sensor. Please select from the range of optional sensor mounting brackets. Notes: 1) The model No. with “E” shown on the label affi xed to the ...

Page 9

ORDER GUIDE Basic type (Without operation mode switch and sensitivity adjuster. Cable is 0.5 m Type Appearance Optional (Note 2) NOTE: Mounting bracket is not supplied with the sensor. Please select from the range of optional sensor mounting brackets. Notes: ...

Page 10

ORDER GUIDE 0.5 m 1.640 16.4 ft cable length types 0.5 m 1.640 16.404 ft cable length types (standard When ordering this type, suffi x “-C05” for the 0.5 m ...

Page 11

... Fitted on the front face of the sensor with one- touch. Interference Interference prevention filter prevention fi lter • PF-CX4-V (Vertical, Silver) • PF-CX4-H (Horizontal, Light brown) Two sets of CX-411□ can be mounted close together. • RF-220 • RF-230 8.3 mm 0.327 in 35.3 mm 50.3 mm 1.390 in 1. ...

Page 12

... It is useful for beam alignment of thru-beam type sensors. The optimum CHX-SC2 (Note 3) receiver position is given by indicators, as well as an audio signal. Notes: 1) The plug-in connector type sensor does not allow use of some sensor mounting brackets because of the protrusion of the connector. 2) Refer to the general catalog for details of the universal sensor mounting stand. ...

Page 13

... Sensor Reflector 3) The sensing range and hysteresis of the diffuse refl ective type sensor are specifi ed for white non-glossy paper (200 × 200 slit masks (optional) are fi tted, an object of ø0 Make sure to confi rm detection with an actual sensor before use. ...

Page 14

... RH, Storage Incandescent light: 3,000 ℓx at the light-receiving face 1,000 V AC for one min. between all supply terminals connected together and enclosure 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure 10 to 500 Hz frequency 0.118 in double amplitude and Z directions for two hours each ...

Page 15

... Ambient temperature -25 to +55 °C Ambient humidity Ambient illuminance Voltage withstandability Insulation resistance 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 500 Hz frequency, 1.5 mm Shock resistance Emitting element (modulated) Red LED Peak emission wavelength ...

Page 16

... The pink wire is incorporated only for the CX-44□-P adjustable 3) When the mating cable is connected to the plug-in connector *1 • Sensing mode selection input BGS function: Connect FGS function: Connect to +V Connector pin position M8 plug-in connector type 2 Sensing mode selection input (Note 2) 1 ...

Page 17

... Do not use during the initial transient time (50 ms) after in) Sensor the power supply is switched on. mounting Take care that the sensor is not directly exposed to • bracket (Optional) fl uorescent light from a rapid-starter lamp or a high frequency lighting device may affect the sensing performance. • ...

Page 18

DIMENSIONS (Unit: mm in) CX-41□-J Sensitivity adjuster (Note 1) 11.8 0.465 Operation indicator (Orange)(Note 2) Stability indicator (Green)(Note 1) Operation mode switch (Note 1) 20 0.787 11.2 3 0.441 0.118 Beam axis 15.5 0.610 31 25.4 1.220 1.000 2-M3×0.5 0.020 ...

Page 19

DIMENSIONS (Unit: mm in) RF-230 Refl ector (Accessory for the retrorefl ective type sensor) 50.3 1.980 49.3 1.941 59.3 2.335 ( 30 ) 1.181 10 0.394 5 0.197 3.3 0.130 40 1.575 8.3 0.327 Material: Acrylic (Reflector) 2-ø4.6 ø0.181 mounting ...

Page 20

DIMENSIONS (Unit: mm in) MS-CX2-2 15.8 0.622 36 1.417 55 2.165 0.079 Material: Stainless steel (SUS304) Two M3 (length 12 mm 0.472 in) screws with washers are attached. MS-CX2-4 ø55 ø2.165 ø39 ø1.535 6 0.236 20° 40° ...

Page 21

DIMENSIONS (Unit: mm in) MS-CX-3 t 1.2 t 0.047 30 1.181 3.5 20.5 0.138 5 0.807 3.4 10° 0.197 R25 0.134 R0.984 3.4 0.134 35 25 0.984 1.378 R25 3.4 R0.984 0.134 10° 0.591 0.197 Material: Stainless steel ...

Page 22

DIMENSIONS (Unit: mm in) MS-RF23 40 1.575 ( ) 3 0.118 50 1.969 40 1.575 35 1.378 12 0.472 1.024 0.118 ( 28 ) 1.102 Material: Cold rolled carbon steel (SPCC) (Uni-chrome plated) Two M4 (length ...

Page 23

DIMENSIONS (Unit: mm in) MS-AJ1-A Universal sensor mounting stand (Optional) 210 16.5 28.45 0.650 1.120 8.268 ( ) 134 12 5.276 (Note 1) 0.472 6 0.236 4.2 ø10 ø0.394 pipe 0.165 Cable guide [Stainless steel (SUS304)] (POM) Sensor mounting bracket ...

Page 24

Promoting a totally lead-free working environment Protecting the We are now working to environment is eliminate the use of lead in all one of our our in-house manufacturing processes such as in reflow guiding business ovens, hand soldering and principles ...