FV-BR1 PANASONIC EW, FV-BR1 Datasheet

no-image

FV-BR1

Manufacturer Part Number
FV-BR1
Description
VACUUM FIBER TERMINATION 2 NEEDED (THRU)
Manufacturer
PANASONIC EW
Datasheet

Specifications of FV-BR1

Rohs Compliant
YES
PHOTOELECTRIC SENSOR
DIGITAL FIBER SENSOR
FX-300
SERIES
Conforming to
UL Recognition
EMC Directive
Constant advances achieving the highest
level of performance in its class

Related parts for FV-BR1

FV-BR1 Summary of contents

Page 1

Constant advances achieving the highest level of performance in its class PHOTOELECTRIC SENSOR DIGITAL FIBER SENSOR FX-300 Conforming to EMC Directive SERIES UL Recognition ...

Page 2

The FX-300 series of next-generation fiber sensors provides the highest level of sensing performance in its class ‘Stable sensing’, ‘high sensing performance’, ‘easy operation’, ‘improved ease of maintenance’ and ‘preservation of the environment’ are the five concepts underlying the new ...

Page 3

APC circuit has been added, in addition to the four-chemical emitting element. Concept 1 High Stability Concept 5 Eco-friendly Lead-free solder used is gentle on the environment. Full range of fibers Guide for each industry P.9 LCD • Semiconductor / ...

Page 4

High Stability Double coupling lens Stable sensing over long and short periods In addition to a ‘four-chemical emitting element’ which suppresses changes in the light emitting element over time so that a stable level of light emission can be maintained ...

Page 5

Superior Performance Light-emitting amount selection If the light receiving level becomes saturated during close- range sensing or when sensing transparent or minute objects, you can adjust the light emitting amount of the sensor to stabilize sensing without needing to change ...

Page 6

Superior Performance Simplified systems using new operating modes A window comparator mode and differential sensing mode have been added. These modes make it easy to carry out sensing tasks that previously required multiple sensors or involved complex threshold settings. ● ...

Page 7

Easy operation Operation indicator Stability indicator Even beginners can quickly learn how to use the MODE NAVI MODE NAVI uses six RUNn RUN This is the sensing mode. indicators to display the TEACH Incident light level is displayed in the ...

Page 8

Easy Maintenance Communication unit improves equipment starting up and maintenance upstream communication unit SC-GU1-485 The communication unit enables inputs to the digital fiber sensors (such as teaching and data bank switching carried out via a PLC, and also ...

Page 9

Wiring- and labor-saving design allows side- by-side configuration for up to sixteen units FX-301/B/G/H One unit can be used as either a main unit or sub unit The amplifier unit can be used as either a main unit or a ...

Page 10

FOR LCD • SEMICONDUCTOR INDUSTRY Improved stability over long and short periods A four-chemical emitting element for stable sensing over long periods has been added, in addition to an suppresses fluctuations in light amount over short periods. The light amount ...

Page 11

... Vacuum-resistant FT-H30-M1V-S thru-beam type fiber • Sensing range: 250 mm FT-H30-M1V-S Vacuum-resistant side-view lens FV-SV2 • Sensing range greatly increased without taking up space Vacuum-resistant expansion lens FV-LE1 • Sensing range increased by 4 times or more FX-305 FX-305 < > < > digit value Extra width ...

Page 12

FOR LCD • SEMICONDUCTOR INDUSTRY Light emitting amount selection function When sensing transparent objects and minute objects, the light emitting amount can be changed without changing the response time, even for cases where the incident light intensity is fully saturated, ...

Page 13

FOR LCD • SEMICONDUCTOR INDUSTRY External data bank switching and teaching are possible The FX-CH2 external input unit (optional) can be used to carry out teaching and data bank switching operations externally without needing to operate the digital fiber sensors ...

Page 14

FOR ELECTRONIC COMPONENT • AUTOMATIC ASSEMBLY INDUSTRY High-speed response 35 ¨s These digital fiber sensors have the fast response time of 35 !s. They are ideal for sensing minute objects that are moving at high speeds. Interference prevention up to ...

Page 15

FOR ELECTRONIC COMPONENT • AUTOMATIC ASSEMBLY INDUSTRY Wide beam fiber It has a wide sensing width 0.433 in for the FT-WA8/A8 and 32 mm 1.260 in for the FT-WA30/A30 enabling long distance sensing of objects as far ...

Page 16

FOR PHARMACEUTICAL • PACKAGING INDUSTRY Retroreflective type fiber The lineup includes retroreflective type fibers which are ideal for sensing transparent objects. With polarizing filters FR-WKZ11 This fiber has a compact head of W9.5 Equipped with allowable bending radius ...

Page 17

ORDER GUIDE Connector type amplifiers Quick-connection cable is not supplied with the amplifier. Please order it separately. Type Appearance Model No. FX-301 FX-301P FX-301B FX-301BP FX-301G FX-301GP FX-301H FX-301HP FX-301-HS FX-301P-HS FX-305 FX-305P Emitting element Output Type NPN open-collector transistor ...

Page 18

FX-300 ORDER GUIDE Quick-connection cables Quick-connection cable is not supplied with the amplifier. Please order it separately. For FX-301(-HS)/B/G/H Type Model No. CN-73-C1 Length Main cable CN-73-C2 Length (3-core) CN-73-C5 Length CN-71-C1 Length: 1 ...

Page 19

LIST OF FIBERS FX-305 / FX-301 (Red LED type) sensing range (Note 1) Thru-beam type (one pair set) Shape of fiber head Type Sensing range (mm in)(Note 2) (mm in) Lens mountable M4 Lens mountable M4 Sleeve 90 mm 3.543 ...

Page 20

FX-300 LIST OF FIBERS FX-305 / FX-301 (Red LED type) sensing range (Note 1) Thru-beam type (one pair set) Shape of fiber head Type Sensing range (mm in)(Note 2) (mm in) With lens Long sensing range "3 "0.118 "3 "0.118 ...

Page 21

LIST OF FIBERS FX-305 / FX-301 (Red LED type) sensing range (Note 1) Thru-beam type (one pair set) Shape of fiber head Type Sensing range (mm in)(Note 2) (mm in) Easy mounting Top sensing W3 H8 D12 W0.118 H0.315 D0.472 ...

Page 22

... FT-H20-VJ80 (one pair set) • Photo-terminal • Fiber at atmospheric side FT-J8 (one pair set) FV-BR1 (one pair set) The FX-305 and FX-301(-HS) have different sensing modes. FX-305: H-SP, FAST, STD, STDF, LONG, U-LG (no S-D mode) FX-301(-HS): S-D, H-SP, FAST, STD, LONG (no STDF or U-LG mode) : FAST Min ...

Page 23

LIST OF FIBERS FX-305 / FX-301 (Red LED type) sensing range (Note 1) Retroreflective type Shape of fiber head Type Sensing range (mm in)(Note 2, 3) (mm in) W9.5 H5.2 D15 W0.374 H0.205 D0.591 W30 H30 D0.5 W1.181 H1.181 D0.020 ...

Page 24

FX-300 LIST OF FIBERS FX-305 / FX-301 (Red LED type) sensing range (Note 1) Reflective type Shape of fiber head Type Sensing range (mm in)(Note 2, 3) (mm in Sleeve 90 mm 3.543 in M4 "1.48 "0.058 45 ...

Page 25

LIST OF FIBERS FX-305 / FX-301 (Red LED type) sensing range (Note 1) Reflective type Shape of fiber head Type Sensing range (mm in)(Note 2, 3) (mm in) "3 "0.118 110 "3 "0.118 110 90 85 Coaxial 65 2.559 37 ...

Page 26

FX-300 LIST OF FIBERS FX-305 / FX-301 (Red LED type) sensing range (Note 1) Reflective type Shape of fiber head Type Sensing range (mm in)(Note 2, 3) (mm in) Front sensing 1 W10 H7 D2 ...

Page 27

... Cannot use Cannot use 400 mm 15.748 15.748 in 100 t 0.7 mm 3.937 3.937 photo-terminal (FV-BR1) fiber at atmospheric side (FT-J8). Please refer to ‘Vacuum resistant fiber Photo-terminal FV-BR1 (one pair set) • • RF-003 RF-13 fiber, Gray) mixed fiber, Black / Gray) • FX-AT2 fiber) fiber) • ...

Page 28

FX-300 LIST OF SENSING RANGE FOR FX-301(P)-HS Sensing range for ultra high-speed type FX-301(P)-HS in H-SP mode (35 ¨s)(Typical model) Sensing range Fiber model No. (mm in) (Note) FT-B8 160 6.299 FT-FM2 120 4.724 FT-NFM2 40 1.575 FT-E12 2 0.079 ...

Page 29

... Side-view FX-SV1 lens Expansion lens for FV-LE1 vacuum fiber (Note 1) Notes careful when installing the thru-beam type fiber equipped with the expansion lens, as the beam envelope becomes narrow and alignment is difficult. Especially when installing a fiber with many cores (sharp bending fibers and heat-resistant glass fiber), please be sure to use it only after you have adjusted it sufficiently. ...

Page 30

FX-300 FIBER OPTIONS Others Designation Model No. FTP-500 (0.5 m 1.640 FTP-1000 (1 m 3.281 Protective tube FTP-1500 (1.5 m 4.921 ( For thru-beam ) FTP-N500 (0.5 m 1.640 type fiber FTP-N1000 (1 m 3.281 FTP-N1500 (1.5 m 4.921 FDP-500 ...

Page 31

SPECIFICATIONS Type Red LED NPN output FX-301 PNP output FX-301P Item Supply voltage < Red LED / Infrared LED type Power consumption Normal operation: 960 mW or less (Current consumption less supply voltage) ECO ...

Page 32

FX-300 I/O CIRCUIT DIAGRAMS FX-301(-HS) NPN output type Color code D (Brown) V (Note 1) Load (Black) Output Tr 100 mA max. (Note (Blue (Note 1) Internal circuit Users’ circuit Notes: 1) The quick-connection sub ...

Page 33

PRECAUTIONS FOR PROPER USE Teaching • The threshold values can be set by normal mode (2-level teaching, limit teaching or full-auto teaching) or window comparator mode (1-level / 2-level / 3-level teaching) [FX-305(P) only], when the MODE indicator / TEACH ...

Page 34

FX-300 PRECAUTIONS FOR PROPER USE Threshold value fine adjustment Step Description Press the MODE key to light up MODE indicator / ADJ (yellow). 1 For the FX-305(P), select ‘ ’ or ‘ In case the threshold value ...

Page 35

PRECAUTIONS FOR PROPER USE Function table for FX-300 series FX-301(P) (Previous version unit) Four-chemical emitting element APC circuit g Four-chemical emitting element only Light emitting amount selection function g Reduced intensity mode (S-D) 9,999 digit display 150 !s Response time ...

Page 36

FX-300 DIMENSIONS (Unit: mm in) FX-301 Amplifier FX-305 Notes: 1) FX-305 ; Output 1 operation indicator (Orange) 2) FX-305 ; Output 2 operation indicator (Orange) 3) FX-301 ; 3-pin, FX-305 ; 4-pin CN-73-C Main cable (Optional) CN-74-C • Length (L) ...

Page 37

External Input Unit for Digital Sensor / FX-CH2 Conforming to EMC Directive Support for stable sensing and smooth setup changes! Teaching and data bank switching for maximum of 16 digital fiber sensors (FX-301 and FX-305) can be ...

Page 38

ORDER GUIDE Designation NPN input type External input unit PNP input type Connector for input device (1 pc. included as standard with external input unit) Length Quick-connection cable Length (Main cable) Length End plate ...

Page 39

Upper Communication Unit for Digital Sensors / SC-GU1-485 Conforming to EMC Directive We now offer remote maintenance for sensors! Also reduces the work required to the system to start running! Centralized control and setting of scattered digital sensors (FX-301/305) is ...

Page 40

... Enclosure: Heat-resistant ABS Weight 35 g approx. (10 g approx. for SC-GU1-EU) SC-GU1-EU (End unit): 1 pc. Accessories CN-73-C2 [Quick-connection cable (cable length 2 m SC-GU1-CC02 [Link cable (cable length 0.2 m Note: Applicable units are for the FX-301(P) after version update. Do not use the previous version of FX-301(P). ...

Related keywords