HAFBLF0200C2AX5 Honeywell Sensing and Control, HAFBLF0200C2AX5 Datasheet - Page 2

SENSOR AIRFLOW 200SCCM LONG

HAFBLF0200C2AX5

Manufacturer Part Number
HAFBLF0200C2AX5
Description
SENSOR AIRFLOW 200SCCM LONG
Manufacturer
Honeywell Sensing and Control
Series
Zephyr™ HAFr
Datasheet

Specifications of HAFBLF0200C2AX5

Sensing Range
200 sccm
Flow Sensor Type
Air
Voltage - Input
3.3V, 5V
Port Size
Male, 0.210" (5.334mm)
Pressure Max
0.022psi
Supply Voltage Range Dc
-0.3V To 6V
Accuracy
±2.5 %
Air Mass Flow Range
-200 - 200sccm
Port Style
Radial
Peak Reflow Compatible (260 C)
No
Supply Voltage Dc, Max
5V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Switch Function/rating
-
Material - Body
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
480-3312

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HAFBLF0200C2AX5
Manufacturer:
HONEYWELL
Quantity:
20 000
Medical
Table 1: Absolute Maximum Ratings
Note 1: Absolute maximum ratings are the extreme limits that the device will withstand without damage to the device. However, the electrical and
mechanical characteristics are not guaranteed as the maximum limits (above recommended operating conditions) are approached, nor will the
device necessarily operate at absolute maximum ratings.
Table 2: Operating Characteristics
Notes:
1. Custom and extended compensated temperature ranges are possible. Contact Honeywell for details.
2. Accuracy is the maximum deviation from the nominal digital output over the compensated flow range at a reference temperature of 25 C.
3. Total error band includes all errors over the compensated flow range including all effects due to temperature over the compensated
4. Full Scale Span (FSS) is the algebraic difference between the digital output at the forward Full Scale (FS) flow and the digital output at the
5. Response time: time to electrically respond to any mass flow change at the microbridge airflow transducer (response time of the transducer
6. Start-up time: time to first valid reading of serial number proceeding streaming 14-bit flow measurements.
7. Warm-up time: time to the first valid flow measurement after power is applied.
8. Default calibration media is dry nitrogen gas. Please contact Honeywell for other calibration options.
9. Refer to Honeywell Technical Note for I
10. Null accuracy is the maximum deviation in output at 0 SCCM from the ideal transfer function over the compensated temperature range. This
2
POTENTIAL APPLICATIONS
Characteristic
Supply voltage
Voltage on output pin
Storage temperature range
Maximum flow change
Maximum common mode pressure
Maximum flow
Characteristic
Supply voltage
Supply current
Power:
Operating temperature range
Compensated temperature range
Accuracy:
Total error band:
Null accuracy
Response time
Resolution
Start up time
Warm up time
Calibration media
Bus standards
Null stability
Reverse polarity protection
3.3 Vdc
5.0 Vdc
forward flow
reverse flow
forward flow:
reverse flow:
Errors include offset, span, non-linearity, hysteresis and non-repeatability (see Figure 3 for the Accuracy Error Band vs Flow).
temperature range (see Figure 4 for the Total Error Band).
reverse FS flow. Forward flow is defined as flow from P1 to P2 as shown in Figure 4. The references to mass flow (SCCM) refer to gas flows at
the standard conditions of 0 C and atmospheric pressure 760 (101.3 kPa).
may be affected by the pneumatic interface).
includes offset errors, thermal airflow hysteresis and repeatability errors.
Anesthesia delivery machines
Ventricular assist devices (heart pumps)
Hospital diagnostics (spectrometry, gas chromatography)
Nebulizers
Oxygen concentrators
Patient monitoring systems (respiratory monitoring)
Sleep apnea machines
Spirometers
Ventilators
www.honeywell.com/sensing
2
1
C protocol information.
-40 C to 125 C [-40 F to 257 F]
±0.01% FSS maximum deviation from null output after 1000 hours at 25 C
25 psi at 25 C [77 F]
-0.3 Vdc to 6.0 Vdc
-0.3 V to Vsupply
±0.25% FSS or ±2.5% of reading, whichever is greater
±0.25% FSS or ±4.5% of reading, whichever is greater
5.0 SLPM/s
Parameter
±0.25% FSS or ±9% of reading, whichever is greater
±0.25% FSS or ±9% of reading, whichever is greater
10 SLPM
-20 C to 70 C [-4 F to 158 F]
0 C to 50 C [32 F to 122 F]
3.3 Vdc 10%; 5.0 Vdc 10%
I
2
Industrial
C, fast mode (400 kHz)
gaseous nitrogen
Air-to-fuel ratio
Analytical instrumentation (spectrometry, chromatography)
Fuel cells
Gas leak detection
Gas meters
HVAC filters
VAV system on HVAC systems
Meteorolgy
±0.02% FSS
16 mA max.
23 mW typ.
38 mW typ.
Parameter
12 bit min.
1 ms typ.
17 ms
30 ms
no
CAUTION
IMPROPER USE
Do not use these products to sense liquid or
fluid flow.
Failure to comply with these instructions
may result in product damage.
Note
4, 10
2, 4
3, 4
1
5
6
7
8
9