84-7111.500 EAO, 84-7111.500 Datasheet - Page 29

LENS, ROUND, GREEN

84-7111.500

Manufacturer Part Number
84-7111.500
Description
LENS, ROUND, GREEN
Manufacturer
EAO
Datasheet

Specifications of 84-7111.500

Lens Color
Green
Lens Diameter
25mm
Accessory Type
Lens
Actuator Style
Round
Actuator Diameter
22mm
Color
Green
For Use With
84 Series Flush Mount Switch And Indicator With LED Illumination
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Technical Data
Switching system
Material
Mechanical characteristics
Electrical characteristics
0
Emergency-stop
The double-break switching system can be supplied for the
following switching functions:
1 Normally closed, 2 Normally closed, 1 Normally closed +
1 Normally open.
The Normally closed contacts have forced opening according to
EN IEC 60947-5-1
Connection cable
Polyvinylchloride (PVC), operating temperature up to +65 °C
Mushroom-head cap
Polybutylenterephthalate (PBT), as per UL 94 V0 (red items)
Actuator housing
Polyamide (PA 66), as per UL 94 V0, Flat ribbon cable-cover
Polyamide (PA 6.6), as per UL 94 V0
Material of contact
Silver alloy gold plated
Front panel thickness
Standard 1 ... 4 mm
with E-stop protective shroud Typ-Nr. 84-902 1 ... 3 mm
Mounting hole
22.5 mm dia. as per EN IEC 60947-5-1 with anti-twist device
Terminals
Soldering terminals 2.8 x 0.5 mm (solderable), CuSn6 tin-plated
Flat ribbon cable 2-, 4-, or 6-poles 0.35 mm² (AWG 22)
Tightening torque
Fixing nut 80 Ncm
Actuating force
22 N ±4 N
Actuating travel
approx. 4 mm to release the internal operation part
Mechanical lifetime
≥50.000 cycles of operations
Standards
The devices comply with : EN IEC 60947-5-1, EN IEC 60947-5-5
(Emergency-stop), DIN EN ISO 13850, EN IEC 60204
Illumination
LED red with pole reversal, constant current source
Operation Voltage
Current consumption
Rated Operational Voltage U
250 VAC, as per EN IEC 60947-1
Rated Insulation Voltage U
250 V, as per EN IEC 60947-1
5 VDC ... 30 VDC
9.7 mA ... 12.4 mA
i
e
0
0
0
0
Environmental conditions
Rated Impulse Withstand Voltage U
2.5 kV, as per EN IEC 60947-1
Contact resistance
New state ≤ 50 mΩ, as per DIN IEC 60512-2-3
Isolation resistance
>10
60512-2-10
Electrical life
≥50 000 cycles of operations (inductive cosφ 0.4), as per EN IEC
60947-5-1
Voltage
Current
Reduced load ≥50'000 cycles of operations (resistive)
Voltage
Current
Conventional free air thermal current I
5 A, as per EN IEC 60947-5-1
the maximum current in continuous operation and at ambient
temperature must not exceed the quoted maximum values.
Switch rating
Switch rating AC with silver contact (gold plated), service category
AC-15, as per EN IEC 60947-5-1
Voltage
Current
Switch rating DC for silver contact (gold plated), service category
DC-13, as per EN IEC 60947-5-1 (inductive)
Voltage
Current
Current
Recommended minimum operational data
Silver contacts (gold plated)
Voltage
Current
Electric strength
500 VAC, 50 Hz, 1 min, as per DIN IEC 60512-2
Rated conditional short-circuit current
1000 A, type of short-circuit unit 6 A gG, as per EN IEC 60947-5-1
Protection class
Class II, as per EN IEC 60947-5
Overvoltage category
II, as per EN IEC 60947-1
Degree of pollution
3, as per EN IEC 60947-1
Storage temperature
-25 °C ... +80 °C
Operating temperature
-25 °C ... +65 °C
Front protection
IP 65, as per EN IEC 60529
11
Ω between the opend contats at 500 VDC, as per DIN IEC
Plug
Cable
120 VAC
3 A
1 VAC/DC
100 mA
120 VAC
3 A
1 VAC/DC
1 mA
12 VDC 24 VDC 48 VDC 60 VDC 125 VDC 250 VDC
5 A
3 A
240 VAC
1.5 A
4 A
3 A
240 VAC
1.5 A
42 VAC/DC
200 mA
2.1 A
2.1 A
imp
125 VDC
0.55 A
1.7 A
1.7 A
th
05.2009
27
0.55 A
0.55 A
250 VDC
0.27 A
0.27 A
0.27 A
84