ARXP124H PANASONIC EW, ARXP124H Datasheet - Page 5

HIGH FREQUENCY RELAY 2.5GHZ 4.5VDC, SPDT

ARXP124H

Manufacturer Part Number
ARXP124H
Description
HIGH FREQUENCY RELAY 2.5GHZ 4.5VDC, SPDT
Manufacturer
PANASONIC EW
Datasheet

Specifications of ARXP124H

Coil Frequency Max
2.5GHz
Coil Voltage Vdc Nom
4.5V
Contact Current Max
500mA
Contact Voltage Dc Nom
30V
Coil Resistance
50.6ohm
Contact Configuration
SPDT
Coil Type
DC
Vswr
1.2
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
7. Latching relay
1) To ensure accurate operation of the
latching type amidst surrounding
temperature changes and other factors
that might affect the set and reset pulse
times, we recommend a coil impress set
and reset pulse width of at least 30 ms at
the rated operation voltage.
2) The latching type relay is shipped in
the reset position. But jolts during
transport or impacts during installation
can change the reset position. It is,
therefore, advisable to build a circuit in
which the relay can be initialized (set and
reset) just after turning on the power.
8. Measuring method
50 type
Connect connectors 1 and 2 respectively
to PORT 1 and PORT 2. Perform
calibration using the 3.5 mm calibration
kit (HP85052B).
After calibration, connect the D.U.T.
board and measure. However,
connectors other than those for
measurement should be connected with
a 50¾ termination resistor.
PC board
Dimensions (mm inch)
For Cautions for Use, see
ds_61307_en_rxp: 280708J
No.
1
2
SUCOFLEX104
Product name
85130-60011
Agilent
Tech no lo gies
E8 363B
Network
analyzer
SUHNER
a
Agilent
.945
24
b
Solder surface-mount
(SMA) type connectors.
PORT2
PORT1
.095inch-.138inch female
1
1
.138inch-.138inch male
2.4mm-3.5mm female
3.5mm-3.5mm male
.079
2.0
16
.630
Contents
Adapter
Cable
.236
6.0
2
2
Relay Technical Information.
PC board for correction
Dimensions (mm inch)
Material: Glass PTFE double-sided
through hole PC board R-4737
(Matsushita Electric Works)
Board thickness: t = 0.8 mm
Copper plating: 18 m
Connector (SMA type receptacle)
Product name: 01K1808-00 (Waka
Manufacturing Co., Ltd.)
Value has compensation PC board
subtracted only for insertion loss.
(Eliminate loss of connector and PC
board.)
9. Others
1) The switching lifetime is defined under
the standard test condition specified in
the JIS C 5442 standard (temperature 15
to 35C
85%R.H.). Check this with the real device
as it is affected by coil driving circuit, load
type, activation frequency, activation
phase, ambient conditions and other
factors.
Also, be especially careful of loads such
as those listed below.
• When used for AC load-operating and
the operating phase is synchronous,
rocking and fusing can easily occur due
to contact shifting.
• When high-frequency opening and
closing of the relay is performed with a
load that causes arcs at the contacts,
nitrogen and oxygen in the air is fused by
the arc energy and HNO
can corrode metal materials.
Three countermeasures for these are
listed here.
(1) Incorporate an arc-extinguishing
circuit.
(2) Lower the operating frequency
(3) Lower the ambient humidity
.630
16
59 to
95F, humidity 25 to
8.57 (a+b)
.337 (a+b)
Solder surface-mount
(SMA) type connectors
.079
2.0
8.57 (a+b)
.337 (a+b)
.236
6.0
3
is formed. This
.031 inch
2) Use the relay within specifications
such as coil rating, contact rating and on/
off service life. If used beyond limits, the
relay may overheat, generate smoke or
catch fire.
3) Be careful not to drop the relay. If
accidentally dropped, carefully check its
appearance and characteristics before
use.
4) Be careful to wire the relay correctly.
Otherwise, malfunction, overheat, fire or
other trouble may occur.
5) If a relay stays on in a circuit for many
months or years at a time without being
activated, circuit design should be
reviewed so that the relay can remain
non-excited. A coil that receives current
all the time heats, which degrades
insulation earlier than expected. A
latching type relay is recommended for
such circuits.
6) If silicone materials (e.g., silicone
rubbers, silicone oils, silicone coating
agents, silicone sealers) are used in the
vicinity of the relay, the gas emitted from
the silicone may adhere to the contacts of
the relay during opening and closing and
lead to improper contact. If this is the
case, use a material other than silicone.
RX-P (ARXP)
5

Related parts for ARXP124H