ADE7762ARWZ Analog Devices Inc, ADE7762ARWZ Datasheet - Page 21

no-image

ADE7762ARWZ

Manufacturer Part Number
ADE7762ARWZ
Description
IC, POLYPHASE ENERGY METERING, SOIC-28
Manufacturer
Analog Devices Inc
Datasheet

Specifications of ADE7762ARWZ

Ic Function
Polyphase Energy Metering IC With Phase Drop Indication
Supply Voltage Range
4.75V To 5.25V
Operating Temperature Range
-40°C To +85°C
Digital Ic Case Style
SOIC
No. Of Pins
28
Input Impedance
140 KOhm
Measurement Error
0.1%
Voltage - I/o High
2.4V
Voltage - I/o Low
0.8V
Current - Supply
8.5mA
Voltage - Supply
4.75 V ~ 5.25 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
28-SOIC (0.300", 7.50mm Width)
Meter Type
3 Phase
Brief Features
On-Chip Creep Protection, High Frequency Output
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
EVAL-ADE7762EBZ - BOARD EVALUATION FOR ADE7762
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADE7762ARWZ
Manufacturer:
IXYS
Quantity:
1 120
DIGITAL-TO-FREQUENCY CONVERSION
After multiplication, the digital output of the low-pass filter
contains the active power information of each phase. However,
because this LPF is not an ideal brick wall filter implementation,
the output signal also contains attenuated components at the line
frequency and its harmonics, that is, cos(hωt), where h = 1, 2, 3 …
The magnitude response of the filter is given by
where the −3 dB cutoff frequency of the low-pass filter is 8 Hz.
For a line frequency of 50 Hz, this gives an attenuation of
the 2ω (100 Hz) component of approximately −22 dB. The
dominating harmonic is twice the line frequency, that is,
cos(2ωt), due to the instantaneous power signal. Figure 26
shows the instantaneous active power signal at the output of
the CF, which still contains a significant amount of instantane-
ous power information, cos(2ωt).
This signal is then passed to the digital-to-frequency converter
where it is integrated (accumulated) over time to produce an
output frequency. This accumulation of the signal suppresses or
averages out any nondc component in the instantaneous active
power signal.
|
H
( )
f
|
=
1
+
1
8
f
MULTIPLIER
MULTIPLIER
MULTIPLIER
2
VA
VB
VC
IA
IB
IC
LPF
LPF
LPF
Figure 26. Active Power-to-Frequency Conversion
ABS
|X|
|X|
|X|
LPF TO EXTRACT
REAL POWER
(DC TERM)
(11)
Rev. 0 | Page 21 of 28
Σ
Σ
Σ
The average value of a sinusoidal signal is zero. Thus, the
frequency generated by the ADE7762 is proportional to the
average active power. Figure 26 shows the digital-to-frequency
conversion for steady load conditions, that is, constant voltage
and current.
The frequency output CF varies over time, even under steady load
conditions (see Figure 26). This frequency variation is primarily
due to the cos(2ωt) components in the instantaneous active power
signal. The output frequency on CF can be up to 160× higher than
the frequency on F1 and F2. The higher output frequency is
generated by accumulating the instantaneous active power signal
over a much shorter time, while converting it to a frequency. This
shorter accumulation period means less averaging of the cos(2ωt)
component. Therefore, some of this instantaneous power signal
passes through the digital-to-frequency conversion.
Where CF is used for calibration purposes, the frequency counter
should average the frequency to remove the ripple and obtain a
stable frequency. If CF is used to measure energy, for example, in a
microprocessor-based application, the CF output should also be
averaged to calculate power. Because the outputs F1 and F2 operate
at a much lower frequency, significant averaging of the
instantaneous active power signal is carried out. The result is a
greatly attenuated sinusoidal content and a virtually ripple-free
frequency output on F1 and F2, which are used to measure energy
in a stepper motor-based meter.
V× I
FREQUENCY
FREQUENCY
DIGITAL-TO-
DIGITAL-TO-
2
0
INSTANTANEOUS REAL POWER SIGNAL
(FREQUENCY DOMAIN)
CF
F1
F2
FREQUENCY – RAD/S
ω
F1
CF
ATTENUATED BY LPF
TIME
TIME
cos(2ωt)
ADE7762

Related parts for ADE7762ARWZ