3255-050 Measurement Specialties Inc/Schaevitz, 3255-050 Datasheet - Page 2

no-image

3255-050

Manufacturer Part Number
3255-050
Description
SENS ACCLRMTR 50G TEMP COMP
Manufacturer
Measurement Specialties Inc/Schaevitz
Datasheet

Specifications of 3255-050

Rohs Status
RoHS non-compliant
Axis
X or Y
Acceleration Range
±50g
Sensitivity
40mV/g
Voltage - Supply
4.5 V ~ 7 V
Output Type
Analog
Bandwidth
500Hz
Mounting Type
Surface Mount
Package / Case
Adhesive Mount
Interface
-
Other names
3255-50
MSP6890
PC Board Mountable Accelerometer
PERFORMANCE SPECIFICATIONS
Supply Current: 5.0 VDC
Ambient Temperature: 25°C (Unless otherwise specified)
Notes
1.
2.
3.
4.
5.
6.
ORDERING INFORMATION
Accelerometer – Amplified
PARAMETERS
Bandwidth (MIN)
Sensitivity (MIN / TYP/ MAX)
PARAMETERS
Bandwidth (MIN)
Sensitivity (MIN / TYP/ MAX)
PARAMETERS
Zero Acceleration Output
Non-Linearity
Transverse Sensitivity
Supply Voltage
Supply Current
Output Noise
Self-Test Input Voltage
Self-Test Response (Vst = -5V)
Self-Test Input Current (Vst = -5V)
Self-Test Accuracy
Output Source Current (load to ground)
Output Sink Current (supply to load)
Acceleration Limits
Operating Temperature
Storage Temperature
Weight
The output voltage increases from the Zero Acceleration Output for
positive acceleration and decreases for negative acceleration.
Best Fit Straight Line.
Output is ratio metric with supply voltage in the range of (5.0 ± 0.5) V.
Includes effects over operating temperature range.
1 Hz to 10 kHz.
Applying the self-test input voltage simulates an acceleration. The
sensor output is proportional to the square of the voltage difference
between the self-test input and the positive supply. When not using the
self-test function, the self-test input pin should be connected to the
positive supply voltage. For detailed description refer to Technical Note
TN010.
-40°C to +85°C
-40°C to +125°C
1.5 Grams
76.0/80.0/84.0
0-1000
±25G
-0.89
MIN
-30
2.3
4.5
1.0
0.5
-5
7.6/8.0/8.4
0-2000
±250G
38.0/40.0/42.0
ALL RANGES
0-1000
RANGE
RANGE
±50G
-1.48
7.
8.
9.
CONNECTIONS
Feel free to contact customer service with any questions at
Toll free 1(800)745-8008; Phone (757)766-1500; Fax (757)766-4297
TYP
2.5
0.2
5.0
10
1
Self-test input voltage is with respect to supply voltage. For example, if
supply voltage is 5 VDC then Vst = -5 V is equivalent to ground.
The useful frequency range is defined as the range of frequencies over
which the device sensitivity is within ±5% of the DC value.
The alarm output is a digital output which is 0 V during normal operation
and 5 V when the output voltage of the accelerometer die is outside the
normal range. This is the case if there is a malfunction of the
accelerometer or a broken wire bond to the sensor.
6 thru 11
PAD
1
2
3
4
5
3.8/4.0/4.2
0-2400
±500G
19.0/20.0/21.0
FUNCTION
Alarm Function
Signal Output
Ground
+5V Supply
Self Test
No Electrical Connection
0-1500
±100G
-2.07
2000
MAX
2.7
1.0
7.0
0.1
10
3
0
5
±% Span
±% Span
mV p-p
UNITS
UNITS
UNITS
mV/g
mV/g
Volts
Volts
Volts
mA
mA
mA
mA
Hz
Hz
%
G
G
Model 3255
NOTES
NOTES
NOTES
4, 6, 7
1, 4
1, 4
1, 4
6, 7
6, 7
6, 7
June 2001
8
8
2
3
5
2-9

Related parts for 3255-050