DR-60-12 Mean Well, DR-60-12 Datasheet

Linear & Switching Power Supplies 54W 12V 4.5A

DR-60-12

Manufacturer Part Number
DR-60-12
Description
Linear & Switching Power Supplies 54W 12V 4.5A
Manufacturer
Mean Well
Datasheet

Specifications of DR-60-12

Product
Switching
Commercial/medical
Commercial
Output Power Rating
54 W
Input Voltage
88 VAC to 264 VAC, 124 VDC to 370 VDC
Number Of Outputs
1
Output Voltage (channel 1)
12 V
Output Current (channel 1)
4.5 A
Mounting Style
DIN Rail
Output Type
DC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
(Note 4)
OTHERS
NOTE
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
EMI CONDUCTION & RADIATION
INRUSH CURRENT (Typ.)
OVERLOAD
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
60W Single Output Industrial DIN Rail Power Supply
Note.3
Note.2
5V
6.5A
0 ~ 6.5A
32.5W
80mVp-p
4.75 ~ 5.5V
100ms, 30ms/230VAC
100ms/230VAC
88 ~ 264VAC
47 ~ 63Hz
DR-60-5
1.2A/115VAC
105 ~ 160% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
5.75 ~ 6.9V
Protection type : Shut down o/p voltage, re-power on to recover
-20 ~ +60
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
UL60950-1, TUV EN60950-1 a
I/P-O/P:3KVAC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55011,EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A
216.2K hrs min.
78*93*56mm (W*H*D)
0.3Kg; 48pcs/15.4Kg/1.02CUFT
76%
COLD START 18A/115VAC
2.0%
1.0%
1.0%
0.03%/
(0 ~ 50
(Refer to output load derating curve)
124 ~ 370VDC
0.8A/230VAC
MIL-HDBK-217F (25 )
23ms/115VAC at full load
200ms, 30ms/115VAC at full load
pproved, Design refer to
12V
4.5A
0 ~ 4.5A
54W
120mVp-p
11.1 ~ 13.2V
DR-60-12
13.8 ~ 16.2V
82%
36A/230VAC
1.0%
1.0%
1.0%
EN50178
15V
4A
0 ~ 4A
60W
120mVp-p
13.5 ~ 16.5V
DR-60-15
17.25 ~ 20.25V
83%
1.0%
1.0%
1.0%
D R - 6 0
DR-60-24
24V
2.5A
0 ~ 2.5A
60W
150mVp-p
21.6 ~ 26.4V
27.6 ~ 32.4V
84%
File Name:DR-60-SPEC 2010-10-02
1.0%
1.0%
1.0%
s e r i e s

Related parts for DR-60-12

DR-60-12 Summary of contents

Page 1

... Compliance to EN61000-3-2,-3 HARMONIC CURRENT EMS IMMUNITY Compliance to EN61000-4- 11, ENV50204, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A MTBF 216.2K hrs min. OTHERS DIMENSION 78*93*56mm (W*H*D) 0.3Kg; 48pcs/15.4Kg/1.02CUFT PACKING NOTE DR-60-12 12V 4. 4.5A 54W 120mVp-p 11.1 ~ 13.2V 2.0% 1.0% 1.0% 1.0% 1.0% 1.0% ...

Page 2

... Pin No. 1 AC/N 5 AC/L 7 LED 3 ADJ. ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15 Block Diagram EMI I/P FILTER Derating Curve 100 - AMBIENT TEMPERATURE ( ) Assignment RECTIFIERS POWER & SWITCHING FILTER PWM O.L.P. CONTROL (VERTICAL Case No.918B Unit: 46.5 46 RECTIFIERS +V & -V FILTER DETECTION CIRCUIT O.V.P. File Name:DR-60-SPEC 2010-10- ...