E2E2-X5Y1-US Omron, E2E2-X5Y1-US Datasheet - Page 2

Proximity Sensors PROX LONG M18 5mm AC2W-NO UL

E2E2-X5Y1-US

Manufacturer Part Number
E2E2-X5Y1-US
Description
Proximity Sensors PROX LONG M18 5mm AC2W-NO UL
Manufacturer
Omron
Type
Inductive Proximity Sensorr
Datasheets

Specifications of E2E2-X5Y1-US

Maximum Operating Temperature
+ 85 C
Supply Voltage
10 V to 30 V
Operating Supply Voltage
10 V to 30 V
Mounting Style
Cable
Minimum Operating Temperature
- 40 C
Maximum Output Current
300 mA
Features
NO
Sensing Distance
5 mm
Sensor Input
Inductive
Sensing Range
5mm
Mounting Type
Panel
Switch Terminals
Cable
Load Current Rms Max
200mA
Sensing Face Diameter
18mm
Supply Voltage Min
24VAC
Sensor Output
NO
Sensor Housing
Cylindrical
Output Type
NO
Sensing Range Max
5mm
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Accessories (Order Separately)
Mounting Brackets
Protective Covers
Sputter Protective Covers
Ratings and Specifications
E2E2-X@D@ DC 2-Wire Models
*1. Use the E2E2 within the range in which the setting indicator (green LED) is ON (except D2 Models).
*2. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
Item
Sensing distance
Set distance *1
Differential travel
Sensing object
Standard sensing object
Response frequency *2
Power supply voltage
(operating voltage range)
Leakage current
Control
output
Indicators
Operation mode
(with sensing object ap-
proaching)
Protection circuits
Ambient temperature
Ambient humidity
Temperature influence
Voltage influence
Insulation resistance
Dielectric strength
Vibration resistance
(destruction)
Shock resistance
(destruction)
Degree of protection
Connection method
Weight (packed state)
Materi-
als
Accessories
a set distance of half the sensing distance.
Switching
capacity
Residual voltage 3 V max. (Load current: 100 mA, Cable length: 2 m)
Case
Sensing surface PBT
Clamping nuts
Toothed washer Zinc-plated iron
Shielding
Model
Size
3 mm±10%
0 to 2.4 mm
10% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on
page 5.)
Iron,
12 × 12 × 1 mm
1 kHz
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
0.8 mA max.
3 to 100 mA
D1 Models: Operation indicator (red) and setting indicator (green)
D2 Models: Operation indicator (red)
D1 Models: NO
D2 Models: NC
Surge absorber, Load short-circuit protection
Operating/Storage: −25 to 70°C (with no icing or condensation)
Operating/Storage: 35% to 95% (with no condensation)
±10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
50 MΩ min. (at 500 VDC) between current-carrying parts and case
1000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
1,000 m/s
IEC IP67, in-house standard for oil resistance
Pre-wired Models (Standard cable length: 2 m)
Approx. 65 g
Brass
Nickel-plated brass
Instruction sheet
E2E2-X3D@
Shielded
2
10 times each in X, Y, and Z directions
M12
Refer to the timing charts under I/O Circuit Diagrams on page 8 for details.
8 mm±10%
0 to 6.4 mm
Iron,
30 × 30 × 1 mm
800 Hz
E2E2-X8MD@
Unshielded
7 mm±10%
0 to 5.6 mm
Iron,
18 × 18 × 1 mm
500 Hz
Approx. 150 g
E2E2-X7D@
Shielded
M18
14 mm±10%
0 to 11.2 mm
Iron,
30 × 30 × 1 mm
E2E2-X14MD@
400 Hz
Unshielded
10 mm±10%
0 to 8 mm
Iron,
30 × 30 × 1 mm
Approx. 210 g
E2E2-X10D@
Shielded
M30
20 mm±10%
0 to 16 mm
Iron,
54 × 54 × 1 mm
100 Hz
E2E2-X20MD@
Unshielded
E2E2
2

Related parts for E2E2-X5Y1-US