E2E-X8MD1 Omron, E2E-X8MD1 Datasheet - Page 15

Proximity Sensors PROX

E2E-X8MD1

Manufacturer Part Number
E2E-X8MD1
Description
Proximity Sensors PROX
Manufacturer
Omron
Series
E2Er
Datasheets

Specifications of E2E-X8MD1

Maximum Operating Temperature
+ 70 C
Supply Voltage
24 V
Output Voltage
3 V
Operating Supply Voltage
12 V to 24 V
Mounting Style
Panel
Minimum Operating Temperature
- 25 C
Maximum Output Current
100 mA
Features
High visibility indicator
Sensing Distance
8 mm
Sensor Input
Inductive
Sensing Range
8mm
Supply Voltage Range Dc
10V To 30V
Sensor Type
Inductive
Sensing Object
Metallic
Response Frequency
800Hz
Material - Body
Nickel-Plated Brass
Shielding
Shielded
Voltage - Supply
10 V ~ 30 V
Output Type
NPN-NO
Terminal Type
2-Wire
Package / Case
Cylinder, Threaded - M12
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
E2E-X8MD1
Manufacturer:
OMRON
Quantity:
384
E2E-X@T1 AC/DC 2-Wire Models
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
*2. Power Supply Voltage Waveform:
Item
Sensing distance
Set distance
Differential travel
Detectable object
Standard sensing object
Response
frequency *1
Power supply voltage
(operating voltage range) *2
Leakage current
Control
output
Indicators
Operation mode
(with sensing object
approaching)
Protection circuits
Ambient temperature range Operating: −25 to 70°C, Storage: −40 to 85°C (with no icing or condensation)
Ambient humidity range
Temperature influence
Voltage influence
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Degree of protection
Connection method
Weight (packed state)
Materials
Accessories
a set distance of half the sensing distance.
Use a sine wave for the power supply. Using a rectangular AC power supply may result in faulty reset.
DC
AC
Load
current
Residual
voltage
Case
Sensing
surface
Clamping
nuts
Toothed
washer
Shielded
Model
Size
3 mm ±10%
0 to 2.4 mm
10% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 18.)
Iron, 12 × 12 × 1 mm
1 kHz
25 Hz
24 to 240 VDC (20 to 264 VDC)
48 to 240 VAC (40 to 264 VAC)
DC: 1 mA max.
AC: 2 mA max.
5 to 100 mA
DC: 6 V max. (Load current: 100 mA, Cable length: 2 m)
AC: 10 V max. (Load current: 5 mA, Cable length: 2 m)
Operation indicator (red), Setting indicator (green)
NO (Refer to the timing charts under I/O Circuit Diagrams on page 21 for details.)
Load short-circuit protection (20 to 40 VDC only), Surge suppressor
Operating/Storage: 35% to 95% (with no condensation)
±10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
50 MΩ min. (at 500 VDC) between current-carrying parts and case
4,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Destruction: 1,000 m/s
IEC 60529 IP67, in-house standards: oil-resistant
Pre-wired Models (Standard cable length: 2 m)
Approx. 80 g
Nickel-plated brass
PBT
Nickel-plated brass
Zinc-plated iron
Instruction manual
E2E-X3T1
M12
2
10 times each in X, Y, and Z directions
7 mm ±10%
0 to 5.6 mm
Iron, 18 × 18 × 1 mm
0.5 kHz
Approx. 140 g
E2E-X7T1
Shielded
M18
10 mm ±10%
0 to 8 mm
Iron, 30 × 30 × 1 mm
0.4 kHz
Approx. 190 g
E2E-X10T1
M30
E2E
15