LPY5150AL STMicroelectronics, LPY5150AL Datasheet - Page 7

Gyroscopes Dual 0.167 mV deg/s LGA-16

LPY5150AL

Manufacturer Part Number
LPY5150AL
Description
Gyroscopes Dual 0.167 mV deg/s LGA-16
Manufacturer
STMicroelectronics
Datasheet

Specifications of LPY5150AL

Sensing Axis
Dual
Supply Current
6.8 mA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Supply Voltage (max)
3.6 V
Supply Voltage (min)
2.7 V
Sensitivity
0.167 mV/deg/s
Output Type
Analog - Voltage
Package / Case
LGA-16
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LPY5150AL
Manufacturer:
ST
Quantity:
84
LPY5150AL
3
3.1
3.2
3.3
3.4
Terminology
Sensitivity
An angular rate gyroscope is a device that produces a positive-going output voltage for
counterclockwise rotation around the sensitive axis considered. Sensitivity describes the
gain of the sensor and can be determined by applying a defined angular velocity to it. This
value changes very little over temperature and time.
Zero-rate level
Zero-rate level describes the actual output signal if there is no angular rate present. The
zero-rate level of precise MEMS sensors is, to some extent, a result of stress to the sensor
and therefore zero-rate level can slightly change after mounting the sensor onto a printed
circuit board or after exposing it to extensive mechanical stress. This value changes very
little over temperature and time.
Self-test
Self-test allows testing of the mechanical and electrical part of the sensor, allowing the
seismic mass to be moved by means of an electrostatic test-force. The self-test function is
off when the ST pin is connected to GND. When the ST pin is tied to Vdd, an actuation force
is applied to the sensor, emulating a definite Coriolis force. In this case the sensor output will
exhibit a voltage change in its DC level which is also dependent on the supply voltage.
When ST is active, the device output level is given by the algebraic sum of the signals
produced by the velocity acting on the sensor and by the electrostatic test-force. If the output
signals change within the amplitude specified in
working properly and the parameters of the interface chip are within the defined
specifications.
High pass filter reset (HP)
The LPY5150AL provides the possibility to reset the optional external high pass filter by
applying a high logic value to the HP pad. This procedure ensures faster response,
especially during overload conditions. Moreover, this operation is suggested each time the
device is powered.
Doc ID 15809 Rev 2
Table
3, then the mechanical element is
Terminology
7/12

Related parts for LPY5150AL