Si8511-C-IS Silicon Laboratories Inc, Si8511-C-IS Datasheet - Page 10

Board Mount Current Sensors 5A DUAL OUTPUT 5kV

Si8511-C-IS

Manufacturer Part Number
Si8511-C-IS
Description
Board Mount Current Sensors 5A DUAL OUTPUT 5kV
Manufacturer
Silicon Laboratories Inc
Type
AC Current Sensorr
Series
-r
Datasheet

Specifications of Si8511-C-IS

Current Rating
5 A
Supply Voltage
2.7 V to 5.5 V
Frequency Range
50 KHz to 1 MHz
Operating Temperature
- 40 C to + 125 C
Accuracy
5 %
Current - Sensing
5A
Sensitivity
392mV/A
Current - Supply
4mA
Sensor Type
Closed Loop
Voltage - Supply
2.7 V ~ 5.5 V
Output
Configurable
Frequency
50kHz ~ 1MHz
Response Time
-
Polarization
Unidirectional
Package / Case
20-SOIC (0.295", 7.50mm Width)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Si85xx
2.1. Under Voltage Lockout (UVLO)
UVLO is provided to prevent erroneous operation during
device start-up and shutdown or when VDD is
significantly below the specified operating range. The
Si85xx is in UVLO state when VDD < V
During UVLO, the output(s) are held at minimum value
regardless of the amount of current flowing from IIN to
IOUT, and signals on integrator reset inputs R1–R4 are
ignored. The Si85xx exits UVLO when VDD > (V
V
2.2. Device Startup
Upon exit from UVLO, the Si85xx performs a voltage
offset and temperature self-calibration cycle. During this
time, output(s) are held at minimum value and reset
inputs (R1-R4) are ignored. The reset inputs are
enabled at the end of the self-calibration cycle, and an
integrator reset cycle is initiated on the first occurrence
of active signals on R1–R4. A current measurement is
initiated immediately after the completion of the
integrator reset cycle, and the resulting current
waveforms appear on the output pins. This "reset-
measure-reset" pattern repeats throughout steady-state
operation.
10
HYST
INTEGRATOR
FAULT output (Si8517/8/9): Goes low when
external reset timing is in error.
Ease-of-use: Other than conventional power and
grounding techniques, no special board layout
considerations are required. Built-in timing interface
circuits allow already-available system switching
signals to be used for reset with no external circuits
required.
OUTPUT
SUPPLY
STATUS
RESET
Si85xx
Si85xx
).
VDD
VOUT
UNDER VOLTAGE
LOCKOUT STATE
V
UVLO
MIN
+ V
HYST
Figure 4. Si85xx Startup and Control Timing
DON’T CARE
UVLO
SELF-CAL CYCLE
(Figure 4).
Preliminary Rev. 0.21
START-UP
UVLO
tCAL
+
Following End of Self-Cal
First Positive Edge
2.3. Integrator Reset and
The Si85xx measures current flowing from the IIN to
IOUT terminals. Current is allowed to flow in the
opposite direction, but will not be measured (OUT1 and
OUT 2 remain at their minimum values during reverse
current flow. Reverse current flow will not damage the
Si85xx).
To achieve the specified accuracy, the integrator
capacitor must be discharged (reset) for time period t
prior to the start of every measurement cycle. This
cycle-by-cycle reset is implemented by connecting
existing system gate control signals to the R1–R4 inputs
in a way that resets the integrator when no current is
flowing from IIN to IOUT. To achieve rated accuracy, the
reset cycle must be completed prior to the start of the
measurement cycle. For maximum flexibility, integrator
reset operation can be configured in one of two ways:
Option 1: The
Option 2: The timing signals applied to R1–R4 trigger
Current Measurement
RESET
tRP
tR
determined by the states of the timing
signals applied to R1–R4.
the start of reset, and the duration of the
reset
programmable reset timer.
start
MEASURE CURRENT
is
determined
OUT1, OUT2
and
VALID
duration
by
of
an
RESET
tRP
tR
reset
onboard
is
R

Related parts for Si8511-C-IS