V3-129 Honeywell, V3-129 Datasheet - Page 64

no-image

V3-129

Manufacturer Part Number
V3-129
Description
Basic / Snap Action / Limit Switches Snap Act Pin Plunger 11A 2.22N Thru-Hole
Manufacturer
Honeywell
Type
Basicr
Series
V3r
Datasheet

Specifications of V3-129

Contact Form
SPDT
Contact Rating
11 Amps
Actuator
Plunger, Pin
Operating Force
2.22 N
Termination Style
4-Pin M12 Connector
Actuator Style
Pin Plunger
Current Rating (max)
11A
Mechanical Life
10000000
Terminal Type
Screw
Product Depth (mm)
10.2mm
Product Length (mm)
34.6mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Basic Switches
Miniature Double-break
44
Honeywell Sensing and Control
Dim. Dwg. Fig. 1
Dim. Dwg. Fig. 2
Dim. Dwg. Fig. 3
Dim. Dwg. Fig. 4
ORDER GUIDE
1TB1-1
1TB1-2
1TB1-3
41TB5-3
Catalog
Listing
Two-circuit, double-
break end screw
terminals
Two-circuit, double-
break end solder
terminals
Two-circuit, double-
break front solder
terminals
Four-circuit, double-
break front solder
terminals
Description
FEATURES
10 amperes
Power load switching capability up to
Motor handling capacity of
power, 125 VAC
Two- and four-circuit double-break
Several auxiliary actuators
Choice of terminal styles
UL recognized, CSA certified
Momentary action
Electrical
Data And
UL Code
Page 20
10 Amps
10 Amps
10 Amps
10 Amps
Z
Z
Z
Z
Characteristics: O.F. – Operating Force; R.F. – Release Force;
P .T. – Pretravel; O.T. – Overtravel; D.T. – Differential Travel; O.P .
– Operating Position.
newtons
1,95-3,61
1,95-3,61
1,95-3,61
5,56-10,0
ounces
20-36
7-13
7-13
7-13
O.F.
For application help: call 1-800-537-6945.
1
2
R.F. min. P .T. max. O.T. min.
newtons
ounces
horse-
1,11
1,11
1,11
2,22
4
4
4
8
GENERAL INFORMATION
TB miniature switches are basic double-
break units which offer a means of con-
trolling isolated circuits. Each circuit can
be driven by independent voltage sourc-
es. These switches find many uses in
modern control systems because of their
circuitry.
The terminals of two- and four-circuit dou-
ble break switches must be wired to iden-
tical voltage sources and the same polar-
ity so that a voltage potential is not set up
between adjacent terminals. A voltage
potential between adjacent terminals
could promote dielectric breakdown at
high energy levels. The loads should be
on the same sides of the line.
inches
mm
.060
.060
.060
.070
1,52
1,52
1,52
1,78
inches
.010
.010
.010
.010
mm
0,25
0,25
0,25
0,25
.010-.025
.010-.025
.010-0.25
.025-.045
0,25-0,64
0,25-0,64
0,25-0,64
0,64-1,14
inches
D.T.
mm
TB Series
*
inches
O.P .**
.460
.460
.460
.185
mm
11,7
11,7
11,7
4,70
0,38 mm
.015 in

Related parts for V3-129