B88069X1500S102
Manufacturer Part Number
B88069X1500S102
Description
Gas Discharge Tubes (GDTs) / Gas Plasma Arrestors A81-A250X
Manufacturer
EPCOS Inc
Datasheet
1.B88069X1500S102.pdf
(2 pages)
Specifications of B88069X1500S102
Peak Pulse Current
20 KA
Dc Breakover Voltage (nominal)
250 V
Number Of Electrodes
2
Termination Style
Axial
Dimensions
8 mm D x 6.05 mm L
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
DC spark-over voltage
Impulse spark-over voltage
Nominal impulse discharge current (wave 8/20 µs)
Single impulse discharge current
Nominal alternating discharge current (50 Hz, 1 s)
Alternating discharge current (50 Hz, 9 cycles)
Insulation resistance at 100 V
Capacitance at 1 MHz
Arc voltage at 1 A
Glow to arc transition current
Glow voltage
Weight
Operation and storage temperature
Climatic category (IEC 60068-1)
Marking, blue
a)
1)
Terms in accordance with ITU-T Rec. K.12 and DIN 57845/VDE0845
AB E / AB PM
Surge Arrester
2-Electrode-Arrester
xxxx = S102 (100 pcs on 5 taped stripes)
At delivery AQL 0.65 level II, DIN ISO 2859
= T502 (500 pcs on tape and reel)
at 100 V/µs
at 1 kV/µs
1)
- for 99 % of measured values
- typical values of distribution
- for 99 % of measured values
- typical values of distribution
dc
(wave 8/20 µs)
Page 1 of 2
Ordering code:
250
< 550
< 500
< 700
< 650
20
25
10
100
> 10
< 1.5
~ 15
~ 0.5
~ 60
~ 1.5
-40 ... +90
40/ 90/ 21
250
YY
O
± 20
- Nominal voltage
- Year of production
- Non radioactive
B88069X1500xxxx
250 YY O
Issue 01, 27.10.2003
A81-A250X
V
%
V
V
V
V
kA
kA
A
A
G
pF
V
A
V
g
°C
Ω
a)
Related parts for B88069X1500S102
B88069X1500S102 Summary of contents
Page 1
Surge Arrester 2-Electrode-Arrester 1) DC spark-over voltage Impulse spark-over voltage at 100 V/µs - for measured values - typical values of distribution at 1 kV/µs - for measured values - typical values of distribution ...
Page 2
Surge Arrester 2-Electrode-Arrester Not to scale Dimensions in mm Non controlled document EPCOS AG 2002. Reproduction, publication and dissemination of this data sheet, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. Purchase orders ...