E3X-CN21 Omron, E3X-CN21 Datasheet - Page 17

Industrial Photoelectric Sensors Power + input conn Master 4 cond 2M

E3X-CN21

Manufacturer Part Number
E3X-CN21
Description
Industrial Photoelectric Sensors Power + input conn Master 4 cond 2M
Manufacturer
Omron
Type
Photoelectric Sensorsr
Datasheets

Specifications of E3X-CN21

Features
Control the laser with an Amplifier the same size as a Digital Fiber Amplifier
Light Source
Red LED
Connection
Master Connector
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
PNP Output
Note: With E3X-DA@TW models, only channel 1 is output when set for area sensing operation.
Sensor I/O Connectors for Models with M8 Connectors
E3X-DA41-N
E3X-DAB41-N
E3X-DAG41-N
E3X-DAH41-N
E3X-DA41V
E3X-DA8
E3X-DAB8
E3X-DAG8
E3X-DAH8
E3X-DA44V
E3X-DA51-N
E3X-DA9
E3X-DA41TW
E3X-DA8TW
LIGHT ON: ON when the incident level is between the thresholds for channels 1 and 2.
DARK ON: OFF when the incident level is between the thresholds for channels 1 and 2. (Channel 2 is always OFF.)
Model
3
4
2
1
1
2
3
4
Light-ON
Dark-ON
Light-ON
Dark-ON
Light-ON
Dark-ON
Opera-
mode
tion
http://www.ia.omron.com/
XS3F-M421-402-A
XS3F-M421-405-A
XS3F-M422-402-A
XS3F-M422-405-A
Operation
indicator
(orange)
Output
transistor
Load
(e.g., relay)
Operation
indicator
(orange)
Output
transistor
Load
(e.g., relay)
Operation
indicator
(orange)
Output
transistor
Load
(e.g., relay)
Operation
indicator
(orange)
Output
transistor
Load
(e.g., relay)
Operation
indicator
(orange)
Output
transistor
Load
(e.g., relay)
Operation
indicator
(orange)
Output
transistor
Load
(e.g., relay)
CH1/
CH2
CH1/
CH2
No incident light
No incident light
No incident light
No incident light
Incident light
Incident light
Incident light
Incident light
No incident light
No incident light
Timing charts
Incident light
Incident light
Operate
Operate
Operate
Operate
Operate
Operate
Reset
Reset
Reset
Reset
Reset
Reset
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
(Between blue and black)
(Between blue and black)
(Between blue and black)
(Between blue and black)
(Between blue and black)
(Between blue and black)
T
T
Wire colors
T
T
T
T
Brown
White
Blue
Black
Mode selec-
tion switch
(LIGHT ON)
(LIGHT ON)
(LIGHT ON)
(DARK ON)
(DARK ON)
(DARK ON)
D-ON
D-ON
D-ON
L-ON
L-ON
L-ON
Note: Pin 2 is not used.
fication
Classi-
DC
* Load resistance: 10 kΩ min.
Display
Display
Display
Operation
indicator
(orange)
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
Wire colors
Brown
White
Black
Blue
• Connector Pin Arrangement
Note: Pin 2 is not used.
(M-8 Connector only)
Photo-
electric
Sensor
main
circuit
Photo-
electric
Sensor
main
circuit
Photo-
electric
Sensor
main
circuit
Operation indicator (orange)
Operation indicator (orange)
Operation indicator (orange)
Connection
pin No.
Output circuit
1
2
3
4
47 Ω
Power supply (0 V)
Power supply (+V)
1
4
3
Orange
1
Brown
Monitor output
Orange
Blue 3
Black
Black
Blue
Control
output 1
Black
Brown
Brown
Blue
2
Control
output 2
E3X-DA-N
Application
1 to 5 V
Control output
4
Control output
3
Output
Load
Load
---
Load
Load
*
Load
12 to
24 VDC
12 to
24 VDC
12 to
24 VDC
17

Related parts for E3X-CN21