CC-2434K2-CS5 Copeland Communications Inc, CC-2434K2-CS5 Datasheet

no-image

CC-2434K2-CS5

Manufacturer Part Number
CC-2434K2-CS5
Description
MODEM FAX 33K 5V
Manufacturer
Copeland Communications Inc
Datasheet

Specifications of CC-2434K2-CS5

Data Format
V.21, V.22, V.23, Bell 103
Baud Rates
33k
Interface
UART
Voltage - Supply
4.2 V ~ 7 V
Mounting Type
Surface Mount
Package / Case
Module
For Use With
539-1002 - KIT EVALUATION WORLD MODEM II
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Features
Applications
Description
© 2005, Copeland Communications, Inc.
?
?
?
?
?
?
?
?
?
?
?
?
The CC-2435K2 and CC-2417K2 World modem™ FAX is a compact integrated 33Kbaud (14.4Kbaud for CC-
2417K2) modem with Socket Modem™ compatibility. The modems feature a transformer-less DAA meeting
global telephone system requirements, no electro-mechanical components and flexible DSP data pump. The
modem is user-configurable to meet virtually all global telecom requirements. The modem supports serial
host communications via flexible internal UART or a parallel interface. The modem conforms to the industry
standard Socket Modem™ mechanical and interface specifications.
flexibility, many applications and OEM products can be created using the World Modem™ FAX. The World
Modem™ FAX is an ideal modem for world-wide embedded applications due to its flexibility, global
compliance, small size, low power consumption and upgradeability. Copeland Communications World
Modem™ FAX are software and plug compatible and available in 14.4K and 33K baud versions.
Self-contained 14.4K – 33.6K baud modem family
V.29, V.27ter, V.17, V.21 channel 2, V.34 half
duplex, V.34 half duplex
Compliant with global regulatory standards
Distinctive ring detection
Standard & Extended AT command set
Serial host interface
UART or parallel interface
Automatic rate negotiation
Global Embedded applications
Point-of-sale terminals
Set-top boxes
Vending & gaming machines
World Modem™ FAX
Data Sheet
Page 1 of 62
?
?
?
?
?
?
?
?
?
?
?
World Modem™ FAX Datasheet Rev 1.0
Type I and II caller ID decode
Data/Fax discriminator
Compatible with all Copeland Communications
2400, 14.4K, 33K and 56K high speed socket
modems
Socket Modem™ compatible
Low power consumption
Low Power Standby Mode
Small footprint – 1.045” X 2.54”
Security Systems
Remote monitoring & control
Remote telemetry and SCADA
Fax Machines
World Modem™ FAX
Because of its built-in features and

Related parts for CC-2434K2-CS5

CC-2434K2-CS5 Summary of contents

Page 1

... Vending & gaming machines Description The CC-2435K2 and CC-2417K2 World modem™ FAX is a compact integrated 33Kbaud (14.4Kbaud for CC- 2417K2) modem with Socket Modem™ compatibility. The modems feature a transformer-less DAA meeting global telephone system requirements, no electro-mechanical components and flexible DSP data pump. The modem is user-configurable to meet virtually all global telecom requirements ...

Page 2

... Table of Contents Features ...................................................................................................................................1 Applications.............................................................................................................................1 Table of Contents.....................................................................................................................2 Block Diagram.........................................................................................................................3 User-Access Registers (U-Registers)...................................................................................... 35 FCC Compliance ................................................................................................................... 58 CE DECLARATION OF CONFORMITY............................................................................. 60 Revision Information ............................................................................................................. 61 Contact Information............................................................................................................... 62 Legal ..................................................................................................................................... 62 © 2005, Copeland Communications, Inc. Data Sheet World Modem™ FAX Page World Modem™ FAX Datasheet Rev 1.0 ...

Page 3

Block Diagram © 2005, Copeland Communications, Inc. Data Sheet World Modem™ FAX Page World Modem™ FAX Datasheet Rev 1.0 ...

Page 4

Host Interface The host interface control and data signals are 3.3volts and are 5 volt tolerant. The World modem II modems can be directly connected into 3 volt systems. Connect either pin 57 or pin 61 to 3.3V ...

Page 5

Mechanical Outline Mechanical The modem module 0.062 thick FR-4 PC board. The module has two rows of 2mm pins located 24mm on center. The module is designed to plug into 2 mm sockets with the same 24 ...

Page 6

Specifications Item Item Item Fax Rate Fax Rate Fax Rate 33.6 kbps* 33.6 kbps* 33.6 kbps* 31.2 kbps* 31.2 kbps* 31.2 kbps* 28.8 kbps* 28.8 kbps* 28.8 kbps* 26.4 kbps* 26.4 kbps* 26.4 kbps* 24.0 kbps* 24.0 kbps* 24.0 kbps* ...

Page 7

... Pulse Dial Ratio Ring Cadence Call Progress Monitor *NOTE: Supported on CC-2435 Only Asynchronous Serial Interface The Asynchronous Serial Interface is a complete UART consisting of Receive and Transmit signals as well as RTS, CTS, DSR, DTR, DCD and RI control signals. RTS/CTS, DSR/DTR and XON/XOFF flow control are supported ...

Page 8

... DSP data pump, modem controller, on-chip RAM and ROM, codec, DAA and analog output. The World Modem™ FAX accepts standard modem AT commands and provides ITU-T T.31 compliant class one commands with fax connect rates up to 33.6/14.4 kbps over the Public Switched Telephone Network (PSTN). ...

Page 9

Serial Interface The pin out of the serial modem is shown in the figure below. © 2005, Copeland Communications, Inc. Data Sheet World Modem™ FAX Page World Modem™ FAX Datasheet Rev 1.0 ...

Page 10

Serial data DTMF Detection / Generation The World Modem™ FAX provides comprehensive DTMF tone generation by using the “ATDT” command. DTMF detection is only available in voice mode (FCLAS = 8). DTMF digits are reported from the modem to the ...

Page 11

... TIP-RING dc voltage with the line voltage sense (LVS) register (U6C, buts 15:8). The LVS bits have a resolution per bit with an accuracy of approximately ±10%. Bits 0 through 6 of this 8-bit signed two’s complement number indicate the value of the line voltage and the sign bit (7) indicates the polarity of TIP and RING ...

Page 12

Overcurrent Detection The World Modem™ FAX includes and overcurrent detection feature that measures the loop current at a programmable time after the modem goes off-hook. This allows the modem to detect connected to an improper telephone line. ...

Page 13

Reset – A hardware reset is provided to reset the modem controller on power- force the modem back to its default settings. This active low signal has an on-board pull up. Leave this pin unconnected if hardware reset ...

Page 14

... WARNING: ONLY connect one (1) of the power supply pins to either 3. models. Connecting both pins 57 and 61 to different power supplies WILL damage the modem and/or the system it is installed in. See CCI Common Socket Interface Specification for more details. © 2005, Copeland Communications, Inc. Data Sheet World Modem™ FAX Page World Modem™ ...

Page 15

... REVERSAL" polarity reversal was detected or "NO POLARITY REVERSAL" polarity reversal was not detected. In each case, the result code is followed by "OK". If the S7 timeout occurs before a busy tone is detected, the modem will report "NO CARRIER". Polarity reversal monitoring begins after the last digit is dialed and ends when the busy tone is detected or S7 timeout occurs ...

Page 16

Basic AT Command Set (Command Defaults in Bold) (Continued) Command In Identification and checksum. I0 Display World Modem™ chipset version H….etc. I1 Display World Modem™ firmware revision code (numeric). I3 Display line-side revision code. ...

Page 17

... IO Control 0 (U70). The CID, OCD, PPD, and RI bits are also cleared. :M Write to Serial EEPROM. :P Program RAM write. This command is used to upload firmware supplied by CCI to the modem. Contact CCI for more information. :R User-Access Register Read. This command allows the user to read from user-access registers. The format is " ...

Page 18

Basic AT Command Set (Command Defaults in Bold) (Continued) Command +A8C : <value> Calling tone indication <value> Description 0 Indicates that the modem concluded answer tone transmission without reporting detection of any calling tone. 1 Indicates a CNG tone (1100 ...

Page 19

Basic AT Command Set (Command Defaults in Bold) (Continued) Command +GCI = X Country Settings - Automatically configure all registers for a particular country. X Country 0 Japan 9 Australia A Austria F Belgium 16 Brazil 1B Bulgaria 20 Canada ...

Page 20

Basic AT Command Set (Command Defaults in Bold) (Continued) Command +GCI = X (cont) 82 Norway 87 Paraguay 89 Philippines 8A Poland 8B Portugal 9C Singapore 9F South Africa A0 Spain A5 Sweden A6 Switzerland B4 United Kingdom B5 United ...

Page 21

Basic AT Command Set (Command Defaults in Bold) (Continued) Command +IFC Options Specifies the flow control to be implemented. +IFC = A A Specifies the flow control method used by the host to control data from the modem. +IFC = ...

Page 22

Basic AT Command Set (Command Defaults in Bold) (Continued) Command +PCW = X Controls the action to be taken upon detection of call waiting. X Mode 0 Toggle RI# and collect Type II Caller ID if enabled by +VCID. 1 ...

Page 23

Basic AT Command Set (Command Defaults in Bold) (Continued) +VRN = n Ringing tone never appeared timer This command sets the amount of time in seconds the modem will wait looking for Ringing Tone. If the modem does not detect ...

Page 24

... Initiate ITU-T V.54 (ANALOOP) test. Modulation set by &H AT command. Test loop is through the DSP (CC-14.4K2/CC-33K2/CC-56K2 only). The modem echoes data from TX pin back to RX pin. &T3 Initiate ITU-T V.54 (ANALOOP) test. Modulation set by &H AT command. Test loop is through the DSP, DAA interface section, DAA interface and analog hybrid circuit ...

Page 25

Extended AT% Command Set Command %$ Display AT% command settings. %On Answer mode %O1 Modem will auto-answer a call in answer mode. %O2 Modem will auto-answer a call in originate mode. %Vn Automatic Line Status Detection After the %V1 and ...

Page 26

Extended AT\ Command Set Command \$ Display AT\ command settings. \Bn Character length will be automatically set in autobaud mode. \B0 6N1 - six data bits, no parity, one stop bit, one start bit, eight bits total (\N0 only) \B1 ...

Page 27

Fax AT Command Set (Command Defaults in Bold) Command +FCLASS = N Fax mode select n Mode 0 Data mode 1 Fax class 1 / 1.0 mode 8 Voice mode +FAE = n Data/Fax auto answer If enabled, the modem ...

Page 28

Fax AT Command Set (Command Defaults in Bold) (continued) Command +FLO = n Flow Control n Mode 0 No flow control 1 Software (XON/XOFF) flow control 2 Hardware (RTS/CTS) flow control +F34 options Initial V.34 rate control +F34 = A ...

Page 29

... Notes: 1. The connect messages shown in ths table are sent when link negotiation is complete. 2. This message is only supported on the CC-2435K2 the only verbal response code that does not follow the <CR><LF> Result Code <CR><LF> standard. There is no leading <CR><LF> ...

Page 30

... The connect messages shown in ths table are sent when link negotiation is complete. 2. This message is only supported on the CC-2435K2 the only verbal response code that does not follow the <CR><LF> Result Code <CR><LF> standard. There is no leading <CR><LF> ...

Page 31

S-Registers The S command allows reading (Sn?) or writing ( the S-registers. The S-registers store values for functions that typically are rarely changed, such as timers or counters, and the ASCII values of control characters such as carriage ...

Page 32

S Register Definition S-Register (Decimal) 0 Automatic answer - Number of rings the modem must detect before answering a call. 0 disables auto answer. 1 Ring counter. 2 ESC code character. 3 Carriage return character. 4 Linefeed character. 5 Backspace ...

Page 33

... Hang Up Delay Time – Maximum delay between receipt of ATH0 command and hang up. If timeout occurs before all data can be sent, the NO CARRIER (3) result code is sent (operates in V.42 mode only). “OK” response is sent if all data is transmitted before timeout. S38 = 255 ...

Page 34

S-Register Description (Continued) S-Register (Decimal) 42 Blacklisting - The modem will not dial the same number fore than two times in three minutes. An attempt to dial a 3rd time will result in a "BLACKLISTED" result code. If the blacklist ...

Page 35

... User-Access Registers (U-Registers) The :U AT command is used to write these 16-bit U-Registers and the :R command is used to read them. U- registers are identified by a hexadecimal (hex) address. Register Name U00 DT1A0 DT1 registers set the coefficients for stage 1 of the Dial Tone Detect filter. Default is for ...

Page 36

... User-Access Registers (continued) Register Name U17 BT1A0 BT1 registers set the coefficients fo stage 1 of the Busy Tone Detect filter. Default is for U18 BT1B1 FCC countries. U19 BT1B2 U1A BT1A2 U1B BT1A1 U1C BT2A0 Busy tone detect filter stage 2 biquad coefficients. U1D ...

Page 37

... User-Access Registers (continued) Register Name U33 RMOT Ringback cadence minimum on time in seconds multiplied by 7200. U34 DTWD Window to look for dialtone in seconds multiplied by 1000. U35 DMOT Minimum dialtone on time in seconds multiplied by 7200. U37 PD0 Number of pulses to dial 0. U38 PD1 Number of pulses to dial 1. ...

Page 38

... User-Access Registers (continued) Register Name U4F FHT Flash Hook Time. Time corresponding with "!" or "&" dial modifier that the modem goes on-hook during a flash hook (ms units). U50 LCDN Loop current debounce on time (ms units). U51 LCDF Loop current debounce off time (ms units). ...

Page 39

... User-Access Registers (continued) Register Name U87 SAM U9F SASF UA0 SC0 UA1 SC1 UA2 SC2 UA3 SC3 UA4 SC4 UA5 SC5 UA6 SC6 UA7 SC7 UA8 SC8 UA9 SC9 © 2005, Copeland Communications, Inc. Data Sheet Description This is a bit-mapped register. ...

Page 40

Bit Mapped U-Register Summary Reg. Name Bit Bit Bit U4D MOD1 TOCT NHFP U53 MOD2 REV U62 DAAC1 U63 DAAC3 U65 DAAC4 PWMG PDN U66 DAAC5 U67 ITC1 MIN[1:0] U68 ITC2 U6A ITC4 U6C LVS U6E CK1 ...

Page 41

... Calling Tone Enable Disable Enable. 2:0 Reserved Read returns 0. © 2005, Copeland Communications, Inc. Data Sheet D11 D10 NHFD CLPD CCAD FTP DSPDM R/W R/W R/W R/W R/W Function Page World Modem™ FAX Datasheet Rev 1.0 World Modem™ FAX ...

Page 42

... Automatic Calibration Time set to 426 ms Automatic Calibration Time set to 106 ms Isolation Digital Loopback (see the AT&T commands Loopback occurs beyond the DAA interface, out to and including the analog hybrid circuit Enables digital loopback mode across isolation barrier only. 0 Reserved Must be set to 0. ...

Page 43

U63 DAAC3 Bit D15 D14 D13 D12 Name LCS[7:0] Type Rest settings = 0x0003 Bit Name 15:8 lcs[7:0] Off-Hook Loop Current (1.1 mA/bit). 7:4 ACT[3:0] AC Termination Select. ACT[3:0] 0000 0011 0100 1111 3:0 Reserved Read returns 0x3. U65 DAAC4 ...

Page 44

U66 DAAC5 Bit D15 D14 D13 D12 Name Type Reset settings = 0x0040 Bit Name 15:7 Reserved Read returns 0. 6 FDT Frame Detect. (Typically used only for board-level debug Indicates the modem has not established frame lock. ...

Page 45

U67 ITC1 Bit D15 D14 D13 D12 Name MINI[1:0] Type R/W Reset settings = 0x0008 Bit Name 15:14 Reserved Read returns 0. 13:12 MINI[1:0] Minimum Operational Loop Current. Adjusts the minimum loop current at which the DAA can operate. Increasing ...

Page 46

... When set, the DAA responds automatically to a collapse of the line-derived power supply during a billing tone event. When off-hook, if BTE = 1 and BTD goes high, the dc termination is released (800? presented to the line). If BTE and RIM (U70, bit 9) are set (U70, bit1) interrupt also occurs when BTD goes high. 1 ROV Receive Overload ...

Page 47

U6A ITC4 Bit D15 D14 D13 D12 Name Type Reset settings = N/A Bit Name 15:3 Reserved Do not modify. 2 OVL Overload Detected. This bit has the same function as ROV, but clears itself after the overload has been ...

Page 48

... Parallel phone detected since last off-hook event. Clears on :I read Ring Indicator. Active high bit when the modem is on-hook, indicates ring event has occurred. Clears on :I read. 0 DCD Data Carrier Detect (status). Active high bit indicates carrier detected (equivalent to inverse of DCD# pin). ...

Page 49

U71 IO1 Bit D15 D14 D13 D12 Name Type Reset settings = 0x0000 Bit Name 15:5 Reserved Read returns zero. 4 COMP 0 = Disables compression (PCM mode Enables linear compression. 3:1 Reserved Read returns zero. 0 PRT ...

Page 50

... Delay between when the modem goes off-hook and the off-hook intrusion algorithm begins. Default HOI Hang-Up On Intrusion Modem will not automatically hang up when and off-hook PPD interrupt occurs Modem automatically hangs PPD interrupt. If %Vn command are set, HOI also causes the "LINE IN USE" result code upon PPD interrupt. 10 Reserved Read returns zero ...

Page 51

U78 GEN3 Bit D15 D14 D13 D12 Name IB[1:0] Type Reset settings = 0x0000 Bit Name 15:14 IB[1:0] Intrusion Blocking. Defines the method used to block the off-hook intrusion algorithm from operation after dialing has begun intrusion ...

Page 52

U79 GEN4 Bit D15 D14 D13 D12 Name Type Reset settings = 0x0000 Bit Name 15:5 Reserved Read returns 0. 4:0 LVCS[4:0] Line Voltage Current Sense. Represents either the line voltage, loop current, or on-hook line monitor. On-Hook Voltage Monitor ...

Page 53

... ADD Adaptive Dialing 0 = Disable Enable. Attempt DTMF dial the fall back to pulse dial if unsuccessful. First digit is dialed as DTMF dialtone is still present after two seconds, the modem will redial as pulse dialtone detected after two seconds, the modem will continue to dial as DTMF. 5:3 Reserved Read returns zero ...

Page 54

U7C GENC Bit D15 D14 D13 D12 Name Type Reset settings = 0x0000 Bit Name 15:5 Reserved Read returns zero. 4 RIGPO RI# RI#, follows this bit when RIGPIOEN = 1b. 3:1 Reserved Read returns zero. 0 RIGPOEN 0 = ...

Page 55

... Generate <EM><0x45> ("E" for error) in response to any unrecognized in-band commands. 8 FSMS Framed Sub-Mode Startup 0 = Upon successful connection, enter Transport Sub-Mode. An <EM><FLAG> is required to enter Framed Sub-Mode Upon successful connection, immediately enter Framed Sub-Mode. The first received <EM><ERR> from a successful hunt is transformed into an <EM><flag>. ...

Page 56

Parallel Interface Registers Parallel Interface 0 (0x00) Bit Name TX/RX[7:0] Type R/W Reset settings = 0x0000 Bit Name 7:0 TX/RX[7:0] Parallel Interface Transmit/Receive. This register functions similarly to the serial port TX pin on writes to ...

Page 57

... In parallel mode, the –INT pin is trigged by a rising edge on RXF, TXE or INT. 3 INT Interrupt interupt has occurred Indicates that an interrupt (CID, OCD, PPD, RI, or DCD from U70) has occurred. This bit is cleared via the AT:I command. 2 ESC Escape. Operation of this bit in parallel mode is functionally equivalent to the ESC pin in serial mode. ...

Page 58

... Host Interface P – Parallel S – TTL UART -v – Voltage 5 – 5V (all IO is 3.3V and is 5V tolerant) Blank – 3.3V (5V tolerant IO) © 2005, Copeland Communications, Inc. Data Sheet World Modem™ FAX CC-xxxxK2-tsv Page World Modem™ FAX Datasheet Rev 1.0 ...

Page 59

... FCC Compliance Certification Number: US:COPMM00BCC-xxK2 AC-REN: 0.0B DC-REN: NA Connectors: RJ11C Compliance: FCC Part 15 and Part 68 © 2005, Copeland Communications, Inc. Data Sheet World Modem™ FAX Page World Modem™ FAX Datasheet Rev 1.0 ...

Page 60

... Manufacturer’s Name: Copeland Communications, Inc. Manufacturer’s Address: 440 Colony Place Gahanna, OH, USA 43230 Type of Equipment: Information Technology Equipment Model No.: CC-xxK2 World Modem II Family Year of Manufacture: 2004 © 2005, Copeland Communications, Inc. Data Sheet World Modem™ FAX 89/336/EEC with Amending Directives: ...

Page 61

Revision Information Revision 1.0 Initial release © 2005, Copeland Communications, Inc. Data Sheet World Modem™ FAX Page World Modem™ FAX Datasheet Rev 1.0 ...

Page 62

... It is your responsibility to ensure that your application meets with your specifications. No representation or warranty is given and no liability is assumed by Copeland Communications, Incorporated with respect to the accuracy or use of such information, or infringement of patents or other intellectual property rights arising from such use or otherwise. Use of Copeland Communication’ ...