SF400-G Multi-Tech Systems, SF400-G Datasheet - Page 83

no-image

SF400-G

Manufacturer Part Number
SF400-G
Description
INTELLIGENT SMS SERVER 4PORT
Manufacturer
Multi-Tech Systems
Series
MultiModem® iSMSr
Type
SMS Serverr
Datasheets

Specifications of SF400-G

Features
API Commands for Text Messaging
Size
17.40" L x 8.50" W x 1.75" H (441.9mm x 215.9mm x 44.4mm)
For Use With/related Products
Data Transfer Through Cellular GSM Network
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
881-1051
Multi-Tech Systems, Inc.
Sending a Broadcast Trigger Message
We can use the API to send a broadcast trigger message to the MultiModem iSMS.
HTTP API format is:
http://192.168.2.1[:portnumber]/sendmsg?user=user2&passwd=user2&cat=2
[&enc=0][&modem=5]&text=message
-or-
http://192.168.2.1[:portnumber]/sendmsg?user=user2&passwd=user2&cat=2
[&enc=2][&modem=5]&text=message should be hexadecimal form
-or-
http://192.168.2.1[:portnumber]/sendmsg?user=user2&passwd=user2&cat=2
[&enc=3][&modem=5]&text=message should be decimal form
The parameters are:
cat
enc
modem Modem index to send broadcast message
Range : 1 to 4 for SF400
2
Encoding type to send SMS(Optional field)
Range: 0 to 3
Note: Maximum decimal value allowed is 65535.
If enc is not specified in the send API request, default enc will be configured to the
settings of the SMS settings page.
i.e. enc=2, if Unicode is enabled.
enc=1, if Extended ASCII is enabled.
enc=0, if both Extended ASCII and Unicode are disabled.
1 to 8 for SF800
0 for any modem (Broadcast API job will be distributed via all the available
modems)
If modem is not specified in the request, broadcast API job will be distributed
via all the available modems
If modem is specified, broadcast job will be sent via the specified modem.
MultiModem® iSMS User Guide for Administrators
0 - SMS text should be in ASCII form
1 - SMS text should be in Extended ASCII form
2 - SMS text should be in hexadecimal form (i.e. each hexadecimal value
3 - SMS text should be in decimal form (i.e. each decimal Value length
length should be maximum 4, and each hexadecimal value should be
separated by a semi-colon. Example: 0645;41;646)
should be maximum 5, and each decimal value should be separated by a
semi-colon. Example: 1605;65;65300)
Appendix A – Application Programming Interface (API)
83

Related parts for SF400-G