XPCL04DTC Honeywell Sensing and Control, XPCL04DTC Datasheet - Page 10

SENSOR DIFF VACUUM GAGE 4 H2O

XPCL04DTC

Manufacturer Part Number
XPCL04DTC
Description
SENSOR DIFF VACUUM GAGE 4 H2O
Manufacturer
Honeywell Sensing and Control
Series
XPCLr
Datasheets

Specifications of XPCL04DTC

Pressure Type
Differential
Operating Pressure
0.14 PSI, 4" H20
Port Size
Male, 0.19" (4.8mm) Tube, Dual
Output
23 ~ 25mV
Voltage - Supply
3 V ~ 16 V
Termination Style
PCB
Operating Temperature
-25°C ~ 85°C
Package / Case
4-SIP, Dual Top Ports
Sensor Output
Voltage
External Depth
8.1mm
Voltage Rating
12V
Port Style
Barbed
Pressure Measurement Type
Differential
No. Of Ports
2
Mounting Type
Through Hole
Operating Pressure Min
-4Inch-H2O
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
480-2683-5
temperature compensated over 0 °C to
50 °C [32 °F to 122 °F] temperature
range • RoHS compliant • Insensitive to
mounting orientation • Also available with
I
and DIP packages • Absolute, differential,
and gage types • Pressure ranges from 60
mbar to 10 bar [1 psi to 150 psi] • Custom
calibration available • Various pressure
port options • Liquid media option
Benefits: The modular and flexible
design offers customers a variety of
package styles and options, all with the
same industry-leading performance
specifications. The HSC Series is fully
calibrated and temperature compensated
for sensor offset, sensitivity, temperature
effects, and non-linearity using an on-
board Application Specific Integrated
Circuit (ASIC). The internal diagnostic
functions increase system reliability.
These sensors are intended for use with
non-corrosive, non-ionic gases, such
as air and other dry gases. An available
option extends the performance of these
sensors to non-corrosive, non-ionic
liquids. Potential medical applications
include airflow monitors, anesthesia
machines, blood analysis machines, gas
chromatography, gas flow instrumentation,
kidney dialysis machines, oxygen
concentrators, pneumatic controls,
respiratory machines, sleep apnea
equipment, and ventilators. Potential
industrial applications include barometry,
flow calibrators, gas chromatography, gas
flow instrumentation, HVAC, life sciences,
and pneumatic controls.
SSC Series.
Features: Industry-leading long-term
stability • Extremely tight accuracy of
±0.25% FSS BFSL • Total error band of
±2% full scale span maximum • Modular
and flexible design offer customers a
variety of package styles and options,
all with the same industry-leading
performance specifications • Miniature
10 mm x 10 mm [0.39 in x 0.39 in]
package • Low operating voltage
• Extremely low power consumption
• Ratiometric 12-bit analog output
• Precision ASIC conditioning and
temperature compensated over -20 °C to
85 °C [-4 °F to 185 °F] temperature
10
2
C or SPI digital output, and in SMT, SIP
www.honeywell.com/sensing
range • RoHS compliant • Insensitive to
mounting orientation • Internal diagnostic
functions increase system reliability • Also
available with I
in SMT, SIP and DIP packages • Absolute,
differential, gage and compound types
• Pressure ranges from 60 mbar to 10 bar
[1 psi to 150 psi] • Custom calibration
available • Various pressure port options
• Liquid media option
Benefits: The modular and flexible
design offers customers a variety of
package styles and options, all with the
same industry-leading performance
specifications. The SSC Series is fully
calibrated and temperature compensated
for sensor offset, sensitivity, temperature
effects, and non-linearity using an on-
board Application Specific Integrated
Circuit (ASIC). The internal diagnostic
functions increase system reliability.
These sensors are intended for use with
non-corrosive, non-ionic gases, such
as air and other dry gases. An available
option extends the performance of these
sensors to non-corrosive, non-ionic
liquids. Potential medical applications
include airflow monitors, anesthesia
machines, blood analysis machines, gas
chromatography, gas flow instrumentation,
kidney dialysis machines, oxygen
concentrators, pneumatic controls,
respiratory machines, sleep apnea
equipment, and ventilators. Potential
industrial applications include barometry,
flow calibrators, gas chromatography, gas
flow instrumentation, HVAC, life sciences,
and pneumatic controls.
24PC Series.
Features: True wet/wet differential sensing
• Miniature package • Operable after
exposure to frozen conditions • Choice of
termination for gage sensors • DIP and
SMT packages
Benefits: Piezoresistive sensing
technology designed to provide inherently
stable outputs over sensing range. Variety
of gage pressure port configurations for
quick and easy modification. Reduces
sensitivity shift over temperature. Used
to measure vacuum or positive pressure
in potential medical, environmental, and
industrial instrumentation applications.
2
C or SPI digital output, and
26PC Series.
Features: Calibrated and temperature
compensated • True wet/wet differential
sensing • Miniature size • Media flow-
through port • Flow path with minimal
dead space • Operable after exposure to
frozen conditions • Choice of termination
for gage sensors • SIP and DIP packages
Benefits: Piezoresistive sensing
technology designed to provide part
interchangeability and enhanced
performance, reliability and accuracy.
Factory-calibrated sensors designed to
provide pressure sensing performance
with enhanced precision and reliability
in a miniature package. Variety of gage
pressure port configurations designed to
provide quick and easy modification. Used
to measure vacuum or positive pressure
in potential medical, environmental, and
industrial instrumentation applications.
ASDX Series.
Features: Calibrated and temperature
compensated • ASIC-enhanced output
• Analog output with 12-bit resolution
• 12-bit digital output (I
compatible protocol) • Ratiometric output
• Enhanced response time and accuracy
• DIP package • Cost effective
Benefits: Fully calibrated and temperature
compensated with on-board ASIC
designed to provide digital correction
of sensor offset, sensitivity, temperature
coefficients, and non-linearity. Analog
output ratiometric with supply voltage over
compensated supply range with 12-bit
resolution. 12-bit I
protocol allows easy interfacing to most
commonly used microcontrollers and
microprocessors without additional
components and electronic circuitry.
Output is corrected pressure value in
hexadecimal format with 12-bit accuracy
(unsigned) and not ratiometric to the
supply voltage. Offers high level output
on a cost-effective basis. Intended
for use with non-corrosive, non-ionic
working fluids such as air and dry
gases in potential applications such as
flow calibrators, ventilation and air flow
monitors, gas flow instrumentation, sleep
apnea monitoring, and therapy equipment.
2
C- or SPI-compatible
2
C- or SPI-

Related parts for XPCL04DTC