Specifications of E3T-FT11

Sensing Distance
19.685" (500mm)
Sensing Method
Through-Beam
Output Configuration
NPN - Open Collector/Light-ON
Mounting Type
Bracket Mount
Current - Supply
30mA
Voltage - Supply
12 V ~ 24 V
Response Time
1ms
Package / Case
Module, Pre-Wired
Output
NPN
Light Source
Red LED
Connection
Prewired Cable
Sensing Range
500mm
Output Current
50mA
Sensor Output
NPN
Supply Voltage Range Dc
12V To 24V
Sensor Housing
Rectangular
Sensor Input
Optical
Supply Voltage Max
24VDC
Sensing Range Max
500mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
E3TFT11

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
E3T-FT11
Manufacturer:
OSRAM
Quantity:
12 604
J SLITS/APERTURES (ORDER SEPARATELY)
Adjustable Aperture
E39-E10 (Use with E3T-ST1j)
With the Adjustable Aperture
Unit in Place
E39-R37 Reflector
E39-S63 (Use with E3T-ST1j)
E3T
Material:
0.2-mm-thick stainless steel
(301 Stainless)
(0.29)
7.4
Optical axis
1.0±0.05 dia.
0.5±0.05 dia.
(0.29)
7.4
(0.50)
12.6
2 dia.
Two, 2.2 dia.
Two 3.1 dia
(0.54)
13.7
(0.59)
15.1
301 Stainless steel
Shown with Sensor
Notch
(0.74)
18.7
Note: Align the notch direction of
(0.29)
7.4
the slit when installing on
the Emitter and Receiver.
Note: A reflector and a stainless steel mounting
(0.38)
Use of E39-E10 Adjustable Aperture
(Example Dark-ON: E3T-ST12/ST14)
9.7
For Dark-ON:
1. Mount the unit on the receiver.
2. Set the adjuster of the Unit to Max (factory setting is
3. Adjust the optical axis (align) and tighten mounting
4. Place a target between emitter and receiver and
5. Remove the target and confirm that the operation
Note: For Light-ON, adjustment is similar, except that
(At Min.)
at Max).
hardware.
gradually turn the adjuster counterclockwise toward
the Min side. Stop turning the adjuster when the op-
eration indicator and stability indicator (green) turn
ON.
indicator is OFF and the stability indicator (green) is
ON.
plate are supplied together as a set.
indicators would operate in opposite manner as
with Dark-ON.
Stainless steel
mounting plate 0.5
(0.91)
23
(At Center)
E39-S64 (Use with E3T-FT1j)
(0.48)
Reflector
0.6 (with adhesive)
12.3
0.5 dia.
1 dia.
(At Max.)
(0.16)
4.1
Indicator
Adjuster
E3T
11