XC09-009-DK Digi International/Maxstream, XC09-009-DK Datasheet - Page 19

no-image

XC09-009-DK

Manufacturer Part Number
XC09-009-DK
Description
KIT DEV FOR 900MHZ 9600BPS 1MW
Manufacturer
Digi International/Maxstream
Series
XCite™r
Type
Transceiverr
Datasheets

Specifications of XC09-009-DK

Frequency
900MHz
For Use With/related Products
XCite Module (900 MHz, 9600 bps) US and Canada
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
9XCite™ OEM RF Module – Product Manual v2.1 [2007.01.04]
3.4. Automatic DIP Switch Configurations
Each time the RF Modem is powered-on, intelligence on the Max-
Stream Interface Board (located inside the RF Modem) sends AT
Commands that program the modem based on positions of the DIP
Switch. Automatic configurations that take place during the power-on
sequence affect RF Modem parameter values as shown below.
To avoid overwriting previously stored custom configurations (due to the automatic configurations
that take place each time the RF Modem is powered-on), it is necessary to disable a processor
located on the XIB-R interface board. To disable the processor, populate J7 of the XIB-R Interface
Board. (By default, J7 jumper is not populated.)
Table 3‐03. RF Modem Power‐up Options (J7 jumper and Config Switch)
AT Commands Sent as result of DIP Switch Settings (SW = DIP Switch)
Condition
Condition
© 2007 MaxStream, Inc.
If J7 is populated
If Config Switch is pressed
If J7 is NOT populated and Config
Switch is NOT pressed
Serial Interfacing Options
If SW1 is ON (up)
If SW1 is OFF (down)
Exit AT Command Mode
Always
Behavior
Behavior
Processor is disabled and AT Commands are not sent to the RF Modem
Processor is disabled and RF Modem enters into AT Command Mode
Execute logic as shown in Table 6.
AT Commands sent: ATCS 0 (RS-232 Operation: CTS function for CTS line)
ATCD 2 (DO3 - RX LED = low)
AT Commands sent: ATCS 3 (RS-485 or RS-422 Operation)
ATCD 2 (DO3 - RX LED = low)
AT Commands sent: ATCN (Exit AT Command Mode)
     19

Related parts for XC09-009-DK