LV W5AM-JYKY-25-Z OSRAM Opto Semiconductors Inc, LV W5AM-JYKY-25-Z Datasheet - Page 17

LED GREEN 505NM CLEAR SMD

LV W5AM-JYKY-25-Z

Manufacturer Part Number
LV W5AM-JYKY-25-Z
Description
LED GREEN 505NM CLEAR SMD
Manufacturer
OSRAM Opto Semiconductors Inc
Series
Golden DRAGON® Plusr
Datasheet

Specifications of LV W5AM-JYKY-25-Z

Viewing Angle
170°
Color
Green
Current - Test
350mA
Luminous Flux @ Current - Test
74.5lm
Current - Max
1A
Lumens @ Current - Max
136lm
Lumens/watt @ Current - Test
65lm/W
Voltage - Forward (vf) Typ
3.3V
Wavelength
505nm
Lens Style/size
Round, 5mm
Mounting Type
Surface Mount
Package / Case
2-SMD, Gull Wing
Illumination Color
Verde Green
Wavelength/color Temperature
505 nm
Operating Voltage
3.3 V
Operating Current
100 mA
Minimum Operating Temperature
- 40 C
Maximum Operating Temperature
+ 125 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
475-2902-2
Q65110A9063
Released
Revision History: 2010-08-30
Previous Version: 2010-03-17
Wegen der Streichung der LED aus der IEC 60825 erfolgt die Bewertung der Augesicherheit nach dem Standard CIE
S009/E:2002 / IEC 62741 ("photobiological safety of lamps and lamp systems")
Im Risikogruppensystem dieser CIE- Norm erfüllen die in diesem Datenblatt angegebenen LED die "low risk"- Gruppe (die die
sich im "sichtbaren" Spektralbereich auf eine Expositionsdauer von 100s bezieht). Unter realen Umständen (für
Expositionsdauer, Augenpupille, Betrachtungsabstand) geht damit von diesen Bauelementen keinerlei Augengefährdung aus.
Grundsätzlich sollte jedoch erwähnt werden, dass intensive Lichtquellen durch ihre Blendwirkung ein hohes sekundäres
Gefahrenpotenzial besitzen. Wie nach dem Blick in andere helle Lichtquellen (z.B. Autoscheinwerfer) auch, können temporär
eingeschränktes Sehvermögen und Nachbilder je nach Situation zu Irritationen, Belästigungen, Beeinträchtigungen oder sogar
Unfällen führen.
Due to the cancellation of the LED from IEC 60825, the evaluation of eye safety occurs according to the standard CIE
S009/E:2002 / IEC 62741 ("photobiological safety of lamps and lamp systems").
Within the risk grouping system of this CIE standard, the LEDs specified in this data sheet fall into the "low risk" group (relating
to devices in the visible spectrum with an exposure time of 100s). Under real circumstances (for exposure time, eye pupils,
observation distance), it is assumed that no endangerment to the eye exists from these devices.
As a matter of principle, however, it should be mentioned that intense light sources have a high secondary exposure potential
due to their blinding effect. As is also true when viewing other bright light sources (e.g. headlights), temporary reduction in visual
acuity and afterimages can occur, leading to irritation, annoyance, visual impairment, and even accidents, depending on the
situati
Attention please!
The information describes the type of component and shall not be considered as assured characteristics.
Terms of delivery and rights to change design reserved. Due to technical requirements components may contain
dangerous substances. For information on the types in question please contact our Sales Organization.
If printed or downloaded, please find the latest version in the Internet.
Packing
Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office.
By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing
material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs
incurred.
Components used in life-support devices or systems must be expressly authorized for such purpose! Critical
components
OSRAM OS.
2010-08-30
Page
all
4
1, 11
all
17
6) page 18
Subjects (major changes since last revision)
datasheet created
Forward voltage corrected
additional information
data sheet released
eye safety information corrected
may only be used in life-support devices or systems
17
7) page 18
with the express written approval of
Date of change
2009-07-09
2009-09-21
2010-03-01
2010-03-17
2010-08-30
LV W5AM