MF-RX090/72-0 Bourns Inc., MF-RX090/72-0 Datasheet

FUSE PTC RESETTABLE 0.9A HOLD

MF-RX090/72-0

Manufacturer Part Number
MF-RX090/72-0
Description
FUSE PTC RESETTABLE 0.9A HOLD
Manufacturer
Bourns Inc.
Series
MF-RXr
Datasheets

Specifications of MF-RX090/72-0

R Min/max
0.140 ~ 0.310 Ohm
Voltage - Max
72V
Time To Trip
7.2s
Current - Hold (ih) (max)
900mA
Current - Trip (it)
1.8A
Current - Max
40A
Package / Case
Radial
Tripping Current
1.8A
Initial Resistance Max
0.31ohm
Svhc
No SVHC (15-Dec-2010)
Approval Category
UL Recognised
Body Diameter
11.7mm
Case Material
Epoxy Polymer
Current Max
40A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Operating/Storage Temperature ........................-40 °C to +85 °C
Maximum Device Surface Temperature
Passive Aging......................................................+85 °C, 1000 hours ....................................±5 % typical resistance change
Humidity Aging....................................................+85 °C, 85 % R.H. 1000 hours ..................±5 % typical resistance change
Thermal Shock ....................................................+85 °C to -55 °C, 10 times ........................±10 % typical resistance change
Solvent Resistance ............................................MIL-STD-202, Method 215 ........................No change
Vibration ..............................................................MIL-STD-883C, Method 2007.1, ................No change
Test
Visual/Mech. ......................................................Verify dimensions and materials ................Per MF physical description
Resistance ..........................................................In still air @ 23 °C ........................................Rmin ≤ R ≤ Rmax
Time to Trip ........................................................5 times Ihold, Vmax, 23 °C ........................T ≤ max. time to trip (seconds)
Hold Current ......................................................30 min. at Ihold ..........................................No trip
Trip Cycle Life ....................................................Vmax, Imax, 100 cycles ..............................No arcing or burning
Trip Endurance....................................................Vmax, 48 hours ..........................................No arcing or burning
UL File Number ..................................................E 174545S
in Tripped State ................................................125 °C
Electrical Characteristics
MF-RX020/72
MF-RX025/72
MF-RX030/72
MF-RX040/72
MF-RX050/72
MF-RX065/72
MF-RX075/72
MF-RX090/72
MF-RX110/72
MF-RX135/72
MF-RX160/72
MF-RX185/72
MF-RX250/72
MF-RX300/72
MF-RX375/72
Environmental Characteristics
Test Procedures And Requirements For Model MF-RX/72 Series
Model
V max.
Volts
72
72
72
72
72
72
72
72
72
72
72
72
72
72
72
I max.
Amps
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
I hold
Test Conditions
Hold
0.20
0.25
0.30
0.40
0.50
0.65
0.75
0.90
1.10
1.35
1.60
1.85
2.50
3.00
3.75
Condition A
MF-RX/72 Series -
Features
Amperes
72 V rated
Radial leaded devices
Cured, flame retardant epoxy polymer
insulating material meets
UL 94V-0 requirements
RoHS compliant*
Agency recognition:
at 23
°
C
0.40
0.50
0.60
0.80
1.00
1.30
1.50
1.80
2.20
2.70
3.20
3.70
5.00
6.00
7.50
I trip
Trip
1.50
1.00
0.76
0.52
0.41
0.27
0.18
0.14
0.15
0.12
0.09
0.08
0.05
0.04
0.03
Min.
Resistance
at 23
Ohms
Initial
Customers should verify actual device performance in their specific applications.
°
C
PTC Resettable Fuses
Max.
2.84
1.95
1.36
0.86
0.77
0.48
0.40
0.31
0.25
0.19
0.14
0.12
0.08
0.06
0.05
Accept/Reject Criteria
1 Hour (R 1 )
Resistance
at 23
Post-Trip
Ohms
Max.
4.40
3.00
2.10
1.29
1.17
0.72
0.60
0.47
0.38
0.30
0.22
0.19
0.13
0.10
0.08
Applications
Almost anywhere there is a low voltage
power supply, up to 72 V and a load to be
protected, including:
*
°
RoHS Directive 2002/95/EC Jan 27 2003 including Annex
Security and fire alarm systems
Loudspeakers
Power transformers
C
Specifications are subject to change without notice.
Amperes
at 23
12.5
15.0
18.75
1.0
1.25
1.5
2.0
2.5
3.25
3.75
4.5
5.5
6.75
8.0
9.25
Max. Time
°
C
To Trip
Seconds
at 23
11.4
12.6
15.6
19.8
24.0
2.2
2.5
3.0
3.9
4.0
5.3
6.3
7.2
8.2
9.6
°
C
Dissipation
at 23
Tripped
Watts
Power
0.40
0.45
0.50
0.55
0.75
0.90
0.90
1.00
1.50
1.70
1.90
2.10
2.50
2.80
3.20
Typ.
°
C

Related parts for MF-RX090/72-0

MF-RX090/72-0 Summary of contents

Page 1

... Vibration ..............................................................MIL-STD-883C, Method 2007.1, ................No change Test Procedures And Requirements For Model MF-RX/72 Series Test Visual/Mech. ......................................................Verify dimensions and materials ................Per MF physical description Resistance ..........................................................In still air @ 23 °C ........................................Rmin ≤ R ≤ Rmax Time to Trip ........................................................5 times Ihold, Vmax, 23 °C ........................T ≤ max. time to trip (seconds) Hold Current ...

Page 2

... Packaging options: BULK: 500 pcs. per bag. TAPE & REEL: MF-RX020/72-2 ~ MF-RX090/72-2 = 3000 pcs. per reel; MF-RX110/72-2 ~ MF-RX160/72-2 = 1500 pcs. per reel; MF-RX185/72-2 - MF-RX375/72-2 = 1000 pcs. per reel. AMMO-PACK: MF-RX020/72-AP ~ MF-RX090/72-AP = 2000 pcs. per pack; MF-RX110/72-AP ~ MF-RX160/72-AP = 1000 pcs. per pack; MF-RX185/72-AP - MF-RX375/72-AP = 500 pcs ...

Page 3

... MF-RX/72 SERIES, REV. E, 02/08 Specifications are subject to change without notice. 100 C 85 ° C 0.08 0.10 0.12 0.16 0.20 0.26 0.30 0.36 0.44 0.54 0.64 ...

Page 4

... MF-R, MF-R/90, MF-R/600, MF-RX, MF-RX/72 & MF-RX/250 Series Tape and Reel Specifications Devices taped using EIA468–B/IEC286-2 standards. See table below and Figures 1 and 2 for details. Dimension Description Carrier tape width Hold down tape width: Hold down tape Top distance between tape edges ...

Page 5

... MF-R, MF-R/90, MF-R/600, MF-RX, MF-RX/72 & MF-RX/250 Series Tape and Reel Specifications Dimension Description Arbor hole diameter Core diameter: MF-R, MF-RX, MF-R/90 Core diameter: MF-RX/250, MF-R/600 Box: MF-R, MF-RX, MF-R/90 Box: MF-RX/250 Box: MF-R/600 Consecutive missing places: MF-R, MF-RX, MF-R/90 Consecutive missing places: MF-RX/250, MF-R/600 ...

Related keywords