B59980C0080A070 EPCOS Inc, B59980C0080A070 Datasheet - Page 12

PTC RESETTABLE 50MA 63V RAD

B59980C0080A070

Manufacturer Part Number
B59980C0080A070
Description
PTC RESETTABLE 50MA 63V RAD
Manufacturer
EPCOS Inc
Type
PTCr
Datasheet

Specifications of B59980C0080A070

R Min/max
16.50 ~ 25.00 Ohm
Voltage - Max
63V
Current - Hold (ih) (max)
50mA
Current - Trip (it)
110mA
Current - Max
1A
Package / Case
Radial
Mounting Style
Through Hole
Pin Count
2
Screening Level
Industrial
Resistance @ 25c
25Ohm
Percentage Of Resistance Tolerance @ 25c
±25
Operating Temperature Min Deg. C
-40C
Operating Temperature Max Deg. C
85C
Product Length (mm)
Not Requiredmm
Product Height (mm)
Not Requiredmm
Product Depth (mm)
3.5mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Time To Trip
-
Lead Free Status / RoHS Status
Compliant, Lead free / RoHS Compliant
Other names
495-3902
B59980C0080A070
B59980C80A70
B59980C80A70
Mounting
Operation
Please read Cautions and warnings and
Important notes at the end of this document.
Overcurrent protection
Leaded disks, coated, 63 V
Electrode must not be scratched before/during/after the mounting process.
Contacts and housing used for assembly with thermistor have to be clean before mounting. Es-
pecially grease or oil must be removed.
When PTC thermistors are encapsulated with sealing material, the precautions given in chapter
"Mounting instructions", "Sealing and potting" must be observed.
When the thermistor is mounted, there must not be any foreign body between the electrode of
the thermistor and the clamping contact.
The minimum force of the clamping contacts pressing against the PTC must be 10 N.
During operation, the thermistor’s surface temperature can be very high. Ensure that adjacent
components are placed at a sufficient distance from the thermistor to allow for proper cooling at
the thermistors.
Ensure that adjacent materials are designed for operation at temperatures comparable to the
surface temperature of thermistor. Be sure that surrounding parts and materials can withstand
this temperature.
Avoid contamination of thermistor surface during processing.
Use thermistors only within the specified temperature operating range.
Use thermistors only within the specified voltage and current ranges.
Environmental conditions must not harm the thermistors. Use thermistors only in normal at-
mospheric conditions. Avoid use in deoxidizing gases (chlorine gas, hydrogen sulfide gas, am-
monia gas, sulfuric acid gas etc), corrosive agents, humid or salty conditions. Contact with any
liquids and solvents should be prevented.
Be sure to provide an appropriate fail-safe function to prevent secondary product damage
caused by abnormal function (e.g. use VDR for limitation of overvoltage condition).
Page 12 of 15
C910 ... C990

Related parts for B59980C0080A070