EC230X EPCOS Inc, EC230X Datasheet

SURGE ARRESTER 230V GASTUBE 2PIN

EC230X

Manufacturer Part Number
EC230X
Description
SURGE ARRESTER 230V GASTUBE 2PIN
Manufacturer
EPCOS Inc
Series
ECr
Datasheets

Specifications of EC230X

Spark Over Voltage
230V
Tolerance
±15%
Impulse Discharge Current
5.0kA 8x20µs
Package / Case
Axial
Mounting Type
Through Hole
Peak Pulse Current
10 KA
Dc Breakover Voltage (nominal)
230 V
Number Of Electrodes
2
Termination Style
Axial
Failsafe Protection Y/n
N
Mounting Style
Through Hole
Technology
Surge Arrester
Suppressor Type
Gas Discharge
Impulse Sparkover Voltage
700V
Svhc
No SVHC (18-Jun-2010)
Capacitance
2pF
Discharge Current Ac Max
5kA
Impulse Discharge Current Max
5kA
Rohs Compliant
Yes
Insulation Resistance
10Gohm
Sparkover Voltage Dc
230V
Dc Breakover Voltage
230V
Gdt Case Style
Axial Leaded
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
495-1473
B88069X 660S102
B88069X0660S102
B88069X660S102

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EC230X
Manufacturer:
BD
Quantity:
8 276
Part Number:
EC230XG
Manufacturer:
EPCOS
Quantity:
5 264
DC spark-over voltage
Impulse spark-over voltage
Nominal impulse discharge current (wave 8/20 µs)
Single impulse discharge current
Single impulse discharge current
Nominal alternating discharge current (50 Hz, 1 s)
Alternating discharge current (50 Hz, 9 cycles)
Insulation resistance at 100 V
Capacitance at 1 MHz
Arc voltage at 1 A
Glow to arc transition current
Glow voltage
Weight
Operation and storage temperature
Climatic category (IEC 60068-1)
Marking, red
1)
2)
Terms in accordance with ITU-T Rec. K.12 and DIN 57845/VDE0845
AB E / AB PM
Surge Arrester
2-Electrode-Arrester
At delivery AQL 0.65 level II, DIN ISO 2859
In ionized mode
at 100 V/µs
at 1 kV/µs
1) 2)
- for 99 % of measured values
- typical values of distribution
- for 99 % of measured values
- typical values of distribution
dc
(wave 8/20 µs)
(wave 10/350 µs)
Page 1 of 2
Ordering code:
230
< 550
< 500
< 700
< 600
5
10
2.5
5
20
> 10
< 1
~ 12
~ 0.6
~ 80
~ 1.5
-40 ... +90
40/ 90/ 21
EC
230
YY
O
± 15
- Series
- Nominal voltage
- Year of production
- Non radioactive
EC 230 YY O
B88069X0660S102
Issue 05, 18.04.2002
EC230X
V
%
V
V
V
V
kA
kA
kA
A
A
GΩ
pF
V
A
V
g
°C

Related parts for EC230X

EC230X Summary of contents

Page 1

... Terms in accordance with ITU-T Rec. K.12 and DIN 57845/VDE0845 Ordering code: 230 < 550 < 500 < 700 < 600 5 (wave 8/20 µs) 10 (wave 10/350 µs) 2 > 10 < 0 1.5 -40 ... +90 40/ 90 230 YY O Page EC230X B88069X0660S102 V ± GΩ °C EC 230 Series - Nominal voltage - Year of production - Non radioactive Issue 05, 18.04.2002 ...

Page 2

... Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers' Association), unless otherwise agreed Ordering code: Not to scale Dimensions in mm Non controlled document Page EC230X B88069X0660S102 Issue 05, 18.04.2002 ...